Standard battery nomenclature describes portable dry cell batteries that have physical dimensions and electrical characteristics interchangeable between manufacturers. The long history of disposable dry cells means that many manufacturer-specific and national standards were used to designate sizes, long before international standards were reached. Technical standards for battery sizes and types are set by standards organizations such as International Electrotechnical Commission (IEC) and American National Standards Institute (ANSI). Popular sizes are still referred to by old standard or manufacturer designations, and some non-systematic designations have been included in current international standards due to wide use.
Property | Value |
---|---|
dbo:abstract | Standard battery nomenclature describes portable dry cell batteries that have physical dimensions and electrical characteristics interchangeable between manufacturers. The long history of disposable dry cells means that many manufacturer-specific and national standards were used to designate sizes, long before international standards were reached. Technical standards for battery sizes and types are set by standards organizations such as International Electrotechnical Commission (IEC) and American National Standards Institute (ANSI). Popular sizes are still referred to by old standard or manufacturer designations, and some non-systematic designations have been included in current international standards due to wide use. The complete nomenclature for the battery will fully specify the size, chemistry, terminal arrangements, and special characteristics of a battery. The same physically interchangeable cell size may have widely different characteristics; physical interchangeability is not the sole factor in substitution of batteries. National standards for dry cell batteries have been developed by ANSI, JIS, British national standards, and others. Civilian, commercial, government, and military standards all exist. Two of the most prevalent standards currently in use are the IEC 60086 series and the ANSI C18.1 series. Both standards give dimensions, standard performance characteristics, and safety information. Modern standards contain both systematic names for cell types that give information on the composition and approximate size of the cells, as well as arbitrary numeric codes for cell size. (en) El estándar de nomenclatura de pilas, describe baterías de célula secas portátiles que tienen dimensiones físicas y características eléctricas intercambiables entre fabricantes. La larga historia de las células secas desechables, significa que muchos fabricantes diferentes-estándares concretos y nacionales solieron designar medidas, mucho tiempo antes de que se lograrán los estándares internacionales. Los estándares técnicos para medidas de batería y los tipos están establecidos por organizaciones de estándares como la Internacionales Electrotechnical Comisión (IEC) y el Instituto de Estándares Nacional americano (ANSI). Las medidas populares se refieren todavíaa fabricantes o estándares viejos señalamientos, y algunos señalamientos no sistemáticos han sido incluidos en estándares internacionales actuales debido a su amplio uso. La nomenclatura completa para la batería plenamente especificará la medida, química, arreglos terminales y características especiales de una batería. La misma célula físicamente intercambiable la medida puede haber ampliamente características diferentes; físico interchangeability no es el factor único en sustitución de baterías. Los estándares nacionales para baterías de célula seca han sido desarrollados por ANSI, JIS, estándares nacionales británicos, y otros. Civil, anuncio, gobierno y estándares militares todos existen. Dos del más prevalent estándares actualmente en el uso es el IEC 60086 series y el ANSI #C18.1 series. Ambos estándares dan dimensiones, características de rendimiento estándar, e información de seguridad. Los estándares modernos contienen ambos nombres sistemáticos para célula escribe aquello da información en la composición y medida aproximada de las células, así como códigos numéricos arbitrarios para medida de célula. (es) |
dbo:thumbnail | wiki-commons:Special:FilePath/IEC-60086--battery-code.svg?width=300 |
dbo:wikiPageID | 25829181 (xsd:integer) |
dbo:wikiPageLength | 23113 (xsd:nonNegativeInteger) |
dbo:wikiPageRevisionID | 1116603498 (xsd:integer) |
dbo:wikiPageWikiLink | dbr:Electric_battery dbr:Mercury_battery dbr:Primary_battery dbr:Alkaline_battery dbc:Battery_(electricity) dbr:Lithium dbr:D_battery dbr:United_States dbr:Voltage dbr:International_standard dbr:List_of_battery_sizes dbr:Copper(II)_oxide dbr:NEMA dbr:Thionyl_chloride dbr:Battery_recycling dbc:Technical_terminology dbr:Manganese_dioxide dbr:Silver_oxide dbr:Comparison_of_commercial_battery_types dbr:Zinc dbr:Zinc_chloride dbr:List_of_battery_types dbr:Standards_organization dbr:C_battery dbr:Dry_cell dbr:Japanese_Industrial_Standards dbr:ANSI dbr:American_National_Standards_Institute dbr:Ammonium_chloride dbr:France dbr:British_Standards dbr:Nickel-metal_hydride_battery dbr:Oxygen dbr:Carbon_monofluoride dbr:History_of_the_battery dbr:List_of_IEC_technical_committees dbr:Harmonisation_of_law dbr:International_Electrotechnical_Commission dbr:AAAA_battery dbr:AAA_battery dbr:AA_battery dbr:Lead–acid_battery dbr:Transistor_radio dbr:Zinc-air_battery dbr:Zinc-carbon_battery dbr:Diameter dbr:Mercuric_oxide dbr:National_Bureau_of_Standards dbr:Search_for_the_Super_Battery dbr:Nickel_oxyhydroxide_battery dbr:Lithium_battery dbr:Silver-oxide_battery dbr:Nickel-cadmium_battery dbr:Li-Ion dbr:Ni-Cd dbr:Ni-MH dbr:Alkali_metal_hydroxide dbr:Secondary_battery dbr:Iron_disulfide dbr:Starter_battery dbr:File:Button_cells_and_9v_cells_(3).png dbr:File:15A_LR6_AA_battery.jpeg dbr:File:24A_LR03_AAA_battery.jpg dbr:File:Batteries_comparison_4,5_D_C_AA_A..._A23_9V_CR2032_LR44_matchstick-1.jpeg dbr:File:IEC-60086--battery-code.svg dbr:File:IEC-61960_lithium_battery_codes.svg dbr:File:LR44_Button_Cell_Battery_IEC_Standard_Version.jpg |
dbp:wikiPageUsesTemplate | dbt:List_of_IEC_standards dbt:Expand_German dbt:Frac dbt:More_citations_needed_section dbt:Reflist dbt:Short_description dbt:Use_dmy_dates |
dct:subject | dbc:Battery_(electricity) dbc:Technical_terminology |
rdf:type | yago:Abstraction100002137 yago:Measure100033615 yago:WikicatIECStandards yago:Standard107260623 yago:SystemOfMeasurement113577171 |
rdfs:comment | Standard battery nomenclature describes portable dry cell batteries that have physical dimensions and electrical characteristics interchangeable between manufacturers. The long history of disposable dry cells means that many manufacturer-specific and national standards were used to designate sizes, long before international standards were reached. Technical standards for battery sizes and types are set by standards organizations such as International Electrotechnical Commission (IEC) and American National Standards Institute (ANSI). Popular sizes are still referred to by old standard or manufacturer designations, and some non-systematic designations have been included in current international standards due to wide use. (en) El estándar de nomenclatura de pilas, describe baterías de célula secas portátiles que tienen dimensiones físicas y características eléctricas intercambiables entre fabricantes. La larga historia de las células secas desechables, significa que muchos fabricantes diferentes-estándares concretos y nacionales solieron designar medidas, mucho tiempo antes de que se lograrán los estándares internacionales. Los estándares técnicos para medidas de batería y los tipos están establecidos por organizaciones de estándares como la Internacionales Electrotechnical Comisión (IEC) y el Instituto de Estándares Nacional americano (ANSI). Las medidas populares se refieren todavíaa fabricantes o estándares viejos señalamientos, y algunos señalamientos no sistemáticos han sido incluidos en estándares internac (es) |
rdfs:label | Battery nomenclature (en) Nomenclatura de pilas (es) |
owl:sameAs | freebase:Battery nomenclature wikidata:Battery nomenclature dbpedia-es:Battery nomenclature https://global.dbpedia.org/id/5rEeV yago-res:Battery nomenclature yago-res:Battery nomenclature yago-res:Battery nomenclature |
prov:wasDerivedFrom | wikipedia-en:Battery_nomenclature?oldid=1116603498&ns=0 |
foaf:depiction | wiki-commons:Special:FilePath/15A_LR6_AA_battery.jpeg wiki-commons:Special:FilePath/24A_LR03_AAA_battery.jpg wiki-commons:Special:FilePath/IEC-60086--battery-code.svg wiki-commons:Special:FilePath/IEC-61960_lithium_battery_codes.svg wiki-commons:Special:FilePath/Button_cells_and_9v_cells_(3).png wiki-commons:Special:FilePath/Batteries_comparison_..._A23_9V_CR2032_LR44_matchstick-1.jpeg wiki-commons:Special:FilePath/LR44_Button_Cell_Battery_IEC_Standard_Version.jpg |
foaf:isPrimaryTopicOf | wikipedia-en:Battery_nomenclature |
is dbo:wikiPageRedirects of | dbr:IEC_60086 dbr:IEC_61951 dbr:IEC_61960 |
is dbo:wikiPageWikiLink of | dbr:N_battery dbr:Mercury_battery dbr:Primary_battery dbr:Battery_holder dbr:Alkaline_battery dbr:D_battery dbr:Vacuum_tube_battery dbr:Comparison_of_commercial_battery_types dbr:List_of_battery_types dbr:C_battery dbr:Nine-volt_battery dbr:AAAA_battery dbr:AAA_battery dbr:AA_battery dbr:Bunsen_cell dbr:Search_for_the_Super_Battery dbr:Nickel_oxyhydroxide_battery dbr:IEC_60086 dbr:IEC_61951 dbr:IEC_61960 dbr:Lithium_metal_battery dbr:Silver-oxide_battery dbr:Silver_zinc_battery |
is rdfs:seeAlso of | dbr:Electric_battery dbr:Button_cell |
is foaf:primaryTopic of | wikipedia-en:Battery_nomenclature |