Moody Diagram (original) (raw)

Calculate fluid flow friction coefficients from a Moody diagram.

There are two definitions of the friction factor

The SI based friction factor is four times larger than the Imperial based friction factor.

SI based Moody Diagram

The Moody friction factor - λ (or f) - is used in the Darcy-Weisbach major loss equation. The coefficient can be estimated with the diagram below:

moody diagram

If the flow is transient - 2300 < Re < 4000 - the flow varies between laminar and turbulent flow and the friction coefiicient is not possible to determine. The friction factor can usually be interpolated between the laminar value at Re = 2300 and the turbulent value at Re = 4000 .

Example - SI based Friction Factor

For a PVC pipe with absolute roughness k = 0.0015×10-3 (m) , hydraulic diameter d h = 0.01 (m) and Reynolds number Re = 10 7 - the relative rougness can be calculated as

r = k / dh

= (0.0015×10-3 m) / (0.01 m)

= 0.00015

From the diagram above, with the relative rougness and the Reynolds number - the friction factor can be estimated to aprox. 0.013 .

My Short List

The study of fluids - liquids and gases. Involving velocity, pressure, density and temperature as functions of space and time.