This paper presents the installation of an experimental arrangement aimed at qualitative analysis... more This paper presents the installation of an experimental arrangement aimed at qualitative analysis of a submerged anaerobic filter filled with polyurethane cubes expanded performed in laboratory scale. The experiment was loaded with the effluent removed from the post-sedimentation stage of a sewage treatment plant and monitored for a period of 30 days, in which weekly were collected BOD, COD, TSS and VSS samples in order to assess the potential for reduction of the organic load. The system monitoring is ongoing in order to support the assembly on an enlarged scale.
Este estudo teve por objetivo comparar a remoção da matéria orgânica entre dois reatores biológic... more Este estudo teve por objetivo comparar a remoção da matéria orgânica entre dois reatores biológicos de biomassa aderida em escala de bancada utilizando brita graduada nº 04 (reator nº 01) e cubos de espuma de poliuretano (reator nº 02) como meio suporte. Para o TDH de 12,0 h observou-se que o reator nº 02 apresentou redução de DQO e de turbidez superior ao reator nº 01 (DQO: 51,5 ± 15,5 % e 37,1 ± 24,4 %; Turbidez: 62 ± 20,6 % e 45 ± 31 %). Para o TDH de 6,0 h, não houve remoção significativa da DQO em ambos os reatores (reator nº 01: 19,5 ± 6% e reator nº 02: 26,7± 15 %), contudo o reator nº 02 operou com uma taxa de carregamento hidráulica (1,7 m3.m-2.dia-1) superior ao reator nº01 (1,4 m3.m-2.dia-1). Em relação a retenção de sólidos, o efluente coletado em ambos os reatores apresentou concentração de sólidos totais abaixo de 50 mg.L-1, independente do TDH. A partir da análise dos resultados permite-se concluir que nas condições adotadas para o estudo, o filtro anaeróbio preenchido com espuma de poliuretano foi mais eficiente na remoção da matéria orgânica em comparação ao filtro anaeróbio preenchido com brita graduada, além de apresentar um menor peso específico e uma maior área superficial para a formação do biofilme, apresentando-se dessa forma, como uma alternativa viável dentro da matriz tecnológica existente para melhorar a eficiência de sistemas de tratamento que utilizam meio suporte para a retenção da biomassa.
Resumo O Plano Nacional de Saneamento Básico-PLANSAB propôs entre suas metas a universalização do... more Resumo O Plano Nacional de Saneamento Básico-PLANSAB propôs entre suas metas a universalização do acesso à água potável. Nesse contexto, considerando-se um ambiente de escassez hídrica e a manutenção dos atuais padrões de consumo, ressalta-se a importância que o controle de perdas nos sistemas de abastecimento de água adquire a medida em que se amplia o acesso da sociedade à rede pública. Dessa forma, o desenvolvimento de tecnologias e a aplicação de protocolos padronizados para a identificação e controle de vazamentos tornam-se ferramentas relevantes para o planejamento das atividades dos prestadores de serviço em saneamento básico. Nesse sentido, o artigo apresenta a metodologia utilizada em um estudo para a detecção das perdas localizadas dentro de uma área piloto, que serviu de base para a elaboração de um plano de controle que direcionou os trabalhos de campo necessários à redução dessas perdas. O resultado obtido após as intervenções demonstrou-se satisfatório, favorecendo a incorporação da metodologia no planejamento das atividades da empresa. No debate sobre a atual escassez dos recursos hídricos no estado de São Paulo tem-se levantado a questão da qualidade da gestão dos serviços públicos no setor de saneamento e, entre os vários aspectos englobados nessa avaliação, destaca-se a relevância que os indicadores de perdas (IP) adquirem como padrões de eficiência dos sistemas de abastecimento de água. Em síntese, o índice de perdas representa a relação entre o volume perdido total e o volume de água tratada disponibilizado pela concessionária. O volume perdido pode ser resultante de perdas aparentes, tais como fraudes, submedição dos hidrômetros residenciais e erros de leitura ou de perdas reais, tais como, extravasamentos em reservatórios ou vazamentos na rede. [1]. No caso específico dos vazamentos, os quais contribuem significativamente para a elevação dos índices de perdas na rede de distribuição, destacam-se os vazamentos visíveis, que afloram na superfície, sendo normalmente de grande magnitude, e os vazamentos não visíveis ou subterrâneos, de pequena ou de grande magnitude, que necessitam de equipamentos acústicos especiais para sua detecção e localização. Dentre suas principais causas podem ser citadas as falhas na especificação e no controle de qualidade dos materiais utilizados, a falta de qualificação na mão-de-obra para a execução dos serviços e o efeito do tráfego sobre as tubulações enterradas [1].
O Plano Nacional de Saneamento Básico - PLANSAB propôs entre suas metas a universalização do aces... more O Plano Nacional de Saneamento Básico - PLANSAB propôs entre suas metas a universalização do acesso à água potável. Nesse contexto, considerando-se um ambiente de escassez hídrica e a manutenção dos atuais padrões de consumo, ressalta-se a importância que o controle de perdas nos sistemas de abastecimento de água adquire a medida em que se amplia o acesso da sociedade à rede pública. Dessa forma, o desenvolvimento de tecnologias e a aplicação de protocolos padronizados para a identificação e controle de vazamentos tornam-se ferramentas relevantes para o planejamento das atividades dos prestadores de serviço em saneamento básico. Nesse sentido, o artigo apresenta a metodologia utilizada em um estudo para a detecção das perdas localizadas dentro de uma área piloto, que serviu de base para a elaboração de um plano de controle que direcionou os trabalhos de campo necessários à redução dessas perdas. O resultado obtido após as intervenções demonstrou-se satisfatório, favorecendo a incorporação da metodologia no planejamento das atividades da empresa. No debate sobre a atual escassez dos recursos hídricos no estado de São Paulo tem-se levantado a questão da qualidade da gestão dos serviços públicos no setor de saneamento e, entre os vários aspectos englobados nessa avaliação, destaca-se a relevância que os indicadores de perdas (IP) adquirem como padrões de eficiência dos sistemas de abastecimento de água. Em síntese, o índice de perdas representa a relação entre o volume perdido total e o volume de água tratada disponibilizado pela concessionária. O volume perdido pode ser resultante de perdas aparentes, tais como fraudes, submedição dos hidrômetros residenciais e erros de leitura ou de perdas reais, tais como, extravasamentos em reservatórios ou vazamentos na rede. [1]. No caso específico dos vazamentos, os quais contribuem significativamente para a elevação dos índices de perdas na rede de distribuição, destacam-se os vazamentos visíveis, que afloram na superfície, sendo normalmente de grande magnitude, e os vazamentos não visíveis ou subterrâneos, de pequena ou de grande magnitude, que necessitam de equipamentos acústicos especiais para sua detecção e localização. Dentre suas principais causas podem ser citadas as falhas na especificação e no controle de qualidade dos materiais utilizados, a falta de qualificação na mão-de-obra para a execução dos serviços e o efeito do tráfego sobre as tubulações enterradas.
This paper presents the installation of an experimental arrangement aimed at qualitative analysis... more This paper presents the installation of an experimental arrangement aimed at qualitative analysis of a submerged anaerobic filter filled with polyurethane cubes expanded performed in laboratory scale. The experiment was loaded with the effluent removed from the post-sedimentation stage of a sewage treatment plant and monitored for a period of 30 days, in which weekly were collected BOD, COD, TSS and VSS samples in order to assess the potential for reduction of the organic load. The system monitoring is ongoing in order to support the assembly on an enlarged scale.
Este estudo teve por objetivo comparar a remoção da matéria orgânica entre dois reatores biológic... more Este estudo teve por objetivo comparar a remoção da matéria orgânica entre dois reatores biológicos de biomassa aderida em escala de bancada utilizando brita graduada nº 04 (reator nº 01) e cubos de espuma de poliuretano (reator nº 02) como meio suporte. Para o TDH de 12,0 h observou-se que o reator nº 02 apresentou redução de DQO e de turbidez superior ao reator nº 01 (DQO: 51,5 ± 15,5 % e 37,1 ± 24,4 %; Turbidez: 62 ± 20,6 % e 45 ± 31 %). Para o TDH de 6,0 h, não houve remoção significativa da DQO em ambos os reatores (reator nº 01: 19,5 ± 6% e reator nº 02: 26,7± 15 %), contudo o reator nº 02 operou com uma taxa de carregamento hidráulica (1,7 m3.m-2.dia-1) superior ao reator nº01 (1,4 m3.m-2.dia-1). Em relação a retenção de sólidos, o efluente coletado em ambos os reatores apresentou concentração de sólidos totais abaixo de 50 mg.L-1, independente do TDH. A partir da análise dos resultados permite-se concluir que nas condições adotadas para o estudo, o filtro anaeróbio preenchido com espuma de poliuretano foi mais eficiente na remoção da matéria orgânica em comparação ao filtro anaeróbio preenchido com brita graduada, além de apresentar um menor peso específico e uma maior área superficial para a formação do biofilme, apresentando-se dessa forma, como uma alternativa viável dentro da matriz tecnológica existente para melhorar a eficiência de sistemas de tratamento que utilizam meio suporte para a retenção da biomassa.
Resumo O Plano Nacional de Saneamento Básico-PLANSAB propôs entre suas metas a universalização do... more Resumo O Plano Nacional de Saneamento Básico-PLANSAB propôs entre suas metas a universalização do acesso à água potável. Nesse contexto, considerando-se um ambiente de escassez hídrica e a manutenção dos atuais padrões de consumo, ressalta-se a importância que o controle de perdas nos sistemas de abastecimento de água adquire a medida em que se amplia o acesso da sociedade à rede pública. Dessa forma, o desenvolvimento de tecnologias e a aplicação de protocolos padronizados para a identificação e controle de vazamentos tornam-se ferramentas relevantes para o planejamento das atividades dos prestadores de serviço em saneamento básico. Nesse sentido, o artigo apresenta a metodologia utilizada em um estudo para a detecção das perdas localizadas dentro de uma área piloto, que serviu de base para a elaboração de um plano de controle que direcionou os trabalhos de campo necessários à redução dessas perdas. O resultado obtido após as intervenções demonstrou-se satisfatório, favorecendo a incorporação da metodologia no planejamento das atividades da empresa. No debate sobre a atual escassez dos recursos hídricos no estado de São Paulo tem-se levantado a questão da qualidade da gestão dos serviços públicos no setor de saneamento e, entre os vários aspectos englobados nessa avaliação, destaca-se a relevância que os indicadores de perdas (IP) adquirem como padrões de eficiência dos sistemas de abastecimento de água. Em síntese, o índice de perdas representa a relação entre o volume perdido total e o volume de água tratada disponibilizado pela concessionária. O volume perdido pode ser resultante de perdas aparentes, tais como fraudes, submedição dos hidrômetros residenciais e erros de leitura ou de perdas reais, tais como, extravasamentos em reservatórios ou vazamentos na rede. [1]. No caso específico dos vazamentos, os quais contribuem significativamente para a elevação dos índices de perdas na rede de distribuição, destacam-se os vazamentos visíveis, que afloram na superfície, sendo normalmente de grande magnitude, e os vazamentos não visíveis ou subterrâneos, de pequena ou de grande magnitude, que necessitam de equipamentos acústicos especiais para sua detecção e localização. Dentre suas principais causas podem ser citadas as falhas na especificação e no controle de qualidade dos materiais utilizados, a falta de qualificação na mão-de-obra para a execução dos serviços e o efeito do tráfego sobre as tubulações enterradas [1].
O Plano Nacional de Saneamento Básico - PLANSAB propôs entre suas metas a universalização do aces... more O Plano Nacional de Saneamento Básico - PLANSAB propôs entre suas metas a universalização do acesso à água potável. Nesse contexto, considerando-se um ambiente de escassez hídrica e a manutenção dos atuais padrões de consumo, ressalta-se a importância que o controle de perdas nos sistemas de abastecimento de água adquire a medida em que se amplia o acesso da sociedade à rede pública. Dessa forma, o desenvolvimento de tecnologias e a aplicação de protocolos padronizados para a identificação e controle de vazamentos tornam-se ferramentas relevantes para o planejamento das atividades dos prestadores de serviço em saneamento básico. Nesse sentido, o artigo apresenta a metodologia utilizada em um estudo para a detecção das perdas localizadas dentro de uma área piloto, que serviu de base para a elaboração de um plano de controle que direcionou os trabalhos de campo necessários à redução dessas perdas. O resultado obtido após as intervenções demonstrou-se satisfatório, favorecendo a incorporação da metodologia no planejamento das atividades da empresa. No debate sobre a atual escassez dos recursos hídricos no estado de São Paulo tem-se levantado a questão da qualidade da gestão dos serviços públicos no setor de saneamento e, entre os vários aspectos englobados nessa avaliação, destaca-se a relevância que os indicadores de perdas (IP) adquirem como padrões de eficiência dos sistemas de abastecimento de água. Em síntese, o índice de perdas representa a relação entre o volume perdido total e o volume de água tratada disponibilizado pela concessionária. O volume perdido pode ser resultante de perdas aparentes, tais como fraudes, submedição dos hidrômetros residenciais e erros de leitura ou de perdas reais, tais como, extravasamentos em reservatórios ou vazamentos na rede. [1]. No caso específico dos vazamentos, os quais contribuem significativamente para a elevação dos índices de perdas na rede de distribuição, destacam-se os vazamentos visíveis, que afloram na superfície, sendo normalmente de grande magnitude, e os vazamentos não visíveis ou subterrâneos, de pequena ou de grande magnitude, que necessitam de equipamentos acústicos especiais para sua detecção e localização. Dentre suas principais causas podem ser citadas as falhas na especificação e no controle de qualidade dos materiais utilizados, a falta de qualificação na mão-de-obra para a execução dos serviços e o efeito do tráfego sobre as tubulações enterradas.