Thi Lan Nhi Pham | Chabot College (original) (raw)
Uploads
Drafts by Thi Lan Nhi Pham
Thi Lan Nhi Pham, 2022
Electrocardiogram (ECG) is commonly used in medical field in order to diagnose different cardiova... more Electrocardiogram (ECG) is commonly used in medical field in order to diagnose different cardiovascular diseases and patient's general health. ECG Signal are often affected by artifacts from the environment including baseline wander, power line interference and electromyographic (EMG) noise. In this project, ECG Signal to be processed is collected from MIT/BIH (Massachusetts Institute of Technology-Beth Israel Hospital) Arrythmia Database [1]. This method is being tested on one dataset only and serves as a beginner guide to digital signal processing with MATLAB for an affordable, precise, and portable Electrocardiogram device that may be used at underserved hospitals. With MATLAB, to remove the baseline wander, Detrend function can be used to remove low frequency below 0.5 Hz. Powerline interference (50 Hz or 60 Hz) can be filtered out by using bandstop IIR filter. EMG and high frequency noise can be reduced by using IIR low-pass filter to cut off high frequency signal. The resulting signal is filtered out successfully with less noise and P wave, QRS complex, T wave can be inferred properly.
Thi Lan Nhi Pham, 2022
Electrocardiogram (ECG) is commonly used in medical field in order to diagnose different cardiova... more Electrocardiogram (ECG) is commonly used in medical field in order to diagnose different cardiovascular diseases and patient's general health. ECG Signal are often affected by artifacts from the environment including baseline wander, power line interference and electromyographic (EMG) noise. In this project, ECG Signal to be processed is collected from MIT/BIH (Massachusetts Institute of Technology-Beth Israel Hospital) Arrythmia Database [1]. This method is being tested on one dataset only and serves as a beginner guide to digital signal processing with MATLAB for an affordable, precise, and portable Electrocardiogram device that may be used at underserved hospitals. With MATLAB, to remove the baseline wander, Detrend function can be used to remove low frequency below 0.5 Hz. Powerline interference (50 Hz or 60 Hz) can be filtered out by using bandstop IIR filter. EMG and high frequency noise can be reduced by using IIR low-pass filter to cut off high frequency signal. The resulting signal is filtered out successfully with less noise and P wave, QRS complex, T wave can be inferred properly.