2017 International Conference on Trends in Electronics and Informatics (ICEI), 2017
Day by day, energy demand keeps rising so that it is essential to reduce energy consumption for t... more Day by day, energy demand keeps rising so that it is essential to reduce energy consumption for that energy conservation is needed. For Conservation of energy the best option is energy audit. Energy audit is a process to determine when, where, why and how energy is used in a plant or building. Collection of these information helps to identify the situation where there is need to improve energy efficiency and decrease production cost. Normally, an energy audit is carried out by certified energy Auditors. By conducting energy audit process in industry, employees begin considering energy as a manageable expense and try to conserve it in day-to-day action. This project aims to carry out lighting audit and electric load management audit in Rajarambapu Patil Sahakari Dudh Sangh Ltd, Islampur. The main objective of this project is to evaluate use of energy in above industry for lighting purpose and determine the opportunities for energy saving with energy efficient equipment's or techniques have to be adopt in industry to make industry more energy efficient through energy audit.
2020 5th International Conference on Communication and Electronics Systems (ICCES), 2020
Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit ... more Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit is a consumption index that normalizes the state of the energy crisis by providing savings plans. Any organization called a large electricity consumer the use of appropriate energy-saving technologies or solutions minimizes energy consumption. Collecting this information provides consumers the idea of improving energy efficiency and reducing costs. Energy control of lighting and management of electrical load audit work was carried out to evaluate energy consumption, therefore energy savings opportunities identified implementing energy-efficient equipment or technologies to be adopted at the institution to minimize the energy consumption. A comparative analysis of the energy flow has been done in ETAP software that uses existing types of equipment and efficient equipment. Effective energy audit process in the college of engineering can focus the employees to think of energy as a controllable expenses and tried to save it in their daily work.
2015 International Conference on Energy Systems and Applications, 2015
The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It i... more The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It is a variable impedance device where the current through reactor is controlled using bidirectional thyristor valves. The application of SVC is initially for load compensation of fast changing loads. Here the objective is to provide dynamic power factor improvement and also balance the currents on the source side whenever required. The work deals with the analytical studies, modeling and simulation of SVC to make it possible competent compensator of current generation. The investigation is carried out on different configuration of SVCs. The result of that thyristor binary compensator (TBC) type of thyristor switched capacitor (TSC) in conjunction with smallest step size thyristor controlled reactor (TCR) configuration turn out to be best solution over major power quality issues.
Process Integration and Optimization for Sustainability, 2022
2020 5th International Conference on Communication and Electronics Systems (ICCES), 2020
Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit ... more Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit is a consumption index that normalizes the state of the energy crisis by providing savings plans. Any organization called a large electricity consumer the use of appropriate energy-saving technologies or solutions minimizes energy consumption. Collecting this information provides consumers the idea of improving energy efficiency and reducing costs. Energy control of lighting and management of electrical load audit work was carried out to evaluate energy consumption, therefore energy savings opportunities identified implementing energy-efficient equipment or technologies to be adopted at the institution to minimize the energy consumption. A comparative analysis of the energy flow has been done in ETAP software that uses existing types of equipment and efficient equipment. Effective energy audit process in the college of engineering can focus the employees to think of energy as a controlla...
Process Integration and Optimization for Sustainability
Power flow analysis is the backbone of power system analysis and design. They are necessary for p... more Power flow analysis is the backbone of power system analysis and design. They are necessary for planning, operation, economic scheduling and exchange of power between utilities. The principal information of power flow analysis is to find the magnitude and phase angle of voltage at each bus and the real and reactive power flowing in each transmission lines. Power flow analysis is an importance tool involving numerical analysis applied to a power system. In this analysis a general and procedural algorithm forY matrix building is proposed in this paper. We know that the procedure for obtaining Y bus or Z bus matrices in any frame of reference. Requires matrix transformation involving inversion and multiplications. It Could Be Very Laborious and time consuming process for large system involving hundreds of nodes or buses. Such an algorithm would be very convenient for various large system that may needed while the system is in operation such as addition of line, removal of lines and cha...
The electrical distribution systems are consists of large losses as the loads are wide spread, le... more The electrical distribution systems are consists of large losses as the loads are wide spread, less effective reactive power compensation facilities and their improper control which results in ineffective utilization of electrical energy. In solution of that the investigation is carried on static VAr compensator (SVC) with thyristor binary compensator. The work deals with the analytical studies and implementation of simulation model of static VAr compensator (SVC) at 3Φ, 50Hz, 11kV/440V, DY-11, 500 kVA distribution transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps in conjunction with smallest step size thyristor controlled reactor. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
The harmonic distortion is a very sensitive issue for all power consumers, causes ill-effects suc... more The harmonic distortion is a very sensitive issue for all power consumers, causes ill-effects such as an increase in loss and current and thereby reduce the life of equipment. The non-linear loads such as be personal computers, automatic machines, adjustable speed drives, lighting ballasts and other power electronic equipment are the main sources of harmonics. In this work, the harmonic mitigation was done of a computer laboratory by shunt connected tuned passive filters. Computer loads contains a switched-mode power supply (SMPS) in the system that generates harmonics at the input side of power supply due to non-sinusoidal current. The simulation work was carried out by modeling personal computer load and single tuned passive filter designed by equal and unequal method. The attractive results for harmonic reduction has been observed. Design of shunt passive power harmonic filters by using equal and unequal branch VAR can be a simple and cost-effective technique for the mitigation o...
Electrical distribution systems are incurring large losses as the loads are wide spread, inadequa... more Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. In solution the experimental studies of static VAr compensator (SVC) with thyristor binary compensator is carried out. The work deals with the performance evaluation through analytical studies and implementation of hardware circuit model of SVC at single phase, 50Hz, 2kVA transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
2020 5th International Conference on Communication and Electronics Systems (ICCES), 2020
The three-phase four wires low voltage supply system to residential, commercial and production ar... more The three-phase four wires low voltage supply system to residential, commercial and production areas in the distribution system is implemented. The different nature of loads connected to the three-wire four-phase distribution system. It can be personal computers, automatic machines, variable speed drives, lighting ballasts and other electronic power equipment, which may produce a nonlinear characteristic cause zero sequence current to flow in the system in the neutral of supply system. This may cause a serious power quality problems, results in reduction. This paper present to reduce the harmonics currents and neutral overloading by using the zigzag transformer. The zigzag transformer is one of the solution to attenuate the neutral current and reduce the zero sequence harmonic currents of the distribution systems.
— The electrical distribution systems are consists of large losses as the loads are wide spread, ... more — The electrical distribution systems are consists of large losses as the loads are wide spread, less effective reactive power compensation facilities and their improper control which results in ineffective utilization of electrical energy. In solution of that the investigation is carried on static VAr compensator (SVC) with thyristor binary compensator. The work deals with the analytical studies and implementation of simulation model of static VAr compensator (SVC) at 3Φ, 50Hz, 11kV/440V, DY-11, 500 kVA distribution transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps in conjunction with smallest step size thyristor controlled reactor. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
— Electrical distribution systems are incurring large losses as the loads are wide spread, inadeq... more — Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. In solution the experimental studies of static VAr compensator (SVC) with thyristor binary compensator is carried out. The work deals with the performance evaluation through analytical studies and implementation of hardware circuit model of SVC at single phase, 50Hz, 2kVA transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
— Electrical distribution systems are incurring large losses as the loads are wide spread, inadeq... more — Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. In solution the experimental studies of static VAr compensator (SVC) with thyristor binary compensator is carried out. The work deals with the performance evaluation through analytical studies and implementation of hardware circuit model of SVC at single phase, 50Hz, 2kVA transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system. Index Terms-reactive power, static VAr compensator, thyristor binary compensator, capacitor bank, binary sequential steps, hardware circuit model, power factor, electrical power system.
— The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It... more — The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It is a variable impedance device where the current through reactor is controlled using bidirectional thyristor valves. The application of SVC is initially for load compensation of fast changing loads. Here the objective is to provide dynamic power factor improvement and also balance the currents on the source side whenever required. The work deals with the analytical studies, modeling and simulation of SVC to make it possible competent compensator of current generation. The investigation is carried out on different configuration of SVCs. The result of that thyristor binary compensator (TBC) type of thyristor switched capacitor (TSC) in conjunction with smallest step size thyristor controlled reactor (TCR) configuration turn out to be best solution over major power quality issues. Keywords—static var compensator, thyristor binary compensator, thyristor switched capacitor, thyristor controlled reactor, power factor, power quality.
— The electrical distribution systems are consists of large losses as the loads are wide spread, ... more — The electrical distribution systems are consists of large losses as the loads are wide spread, less effective reactive power compensation facilities and their improper control which results in ineffective utilization of electrical energy. In solution of that the investigation is carried on static VAr compensator (SVC) with thyristor binary compensator. The work deals with the analytical studies and implementation of simulation model of static VAr compensator (SVC) at 3Φ, 50Hz, 11kV/440V, DY-11, 500 kVA distribution transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps in conjunction with smallest step size thyristor controlled reactor. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
2017 International Conference on Trends in Electronics and Informatics (ICEI), 2017
Day by day, energy demand keeps rising so that it is essential to reduce energy consumption for t... more Day by day, energy demand keeps rising so that it is essential to reduce energy consumption for that energy conservation is needed. For Conservation of energy the best option is energy audit. Energy audit is a process to determine when, where, why and how energy is used in a plant or building. Collection of these information helps to identify the situation where there is need to improve energy efficiency and decrease production cost. Normally, an energy audit is carried out by certified energy Auditors. By conducting energy audit process in industry, employees begin considering energy as a manageable expense and try to conserve it in day-to-day action. This project aims to carry out lighting audit and electric load management audit in Rajarambapu Patil Sahakari Dudh Sangh Ltd, Islampur. The main objective of this project is to evaluate use of energy in above industry for lighting purpose and determine the opportunities for energy saving with energy efficient equipment's or techniques have to be adopt in industry to make industry more energy efficient through energy audit.
2020 5th International Conference on Communication and Electronics Systems (ICCES), 2020
Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit ... more Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit is a consumption index that normalizes the state of the energy crisis by providing savings plans. Any organization called a large electricity consumer the use of appropriate energy-saving technologies or solutions minimizes energy consumption. Collecting this information provides consumers the idea of improving energy efficiency and reducing costs. Energy control of lighting and management of electrical load audit work was carried out to evaluate energy consumption, therefore energy savings opportunities identified implementing energy-efficient equipment or technologies to be adopted at the institution to minimize the energy consumption. A comparative analysis of the energy flow has been done in ETAP software that uses existing types of equipment and efficient equipment. Effective energy audit process in the college of engineering can focus the employees to think of energy as a controllable expenses and tried to save it in their daily work.
2015 International Conference on Energy Systems and Applications, 2015
The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It i... more The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It is a variable impedance device where the current through reactor is controlled using bidirectional thyristor valves. The application of SVC is initially for load compensation of fast changing loads. Here the objective is to provide dynamic power factor improvement and also balance the currents on the source side whenever required. The work deals with the analytical studies, modeling and simulation of SVC to make it possible competent compensator of current generation. The investigation is carried out on different configuration of SVCs. The result of that thyristor binary compensator (TBC) type of thyristor switched capacitor (TSC) in conjunction with smallest step size thyristor controlled reactor (TCR) configuration turn out to be best solution over major power quality issues.
Process Integration and Optimization for Sustainability, 2022
2020 5th International Conference on Communication and Electronics Systems (ICCES), 2020
Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit ... more Energy audits are the easiest way to find the gap between energy supply and demand. Energy audit is a consumption index that normalizes the state of the energy crisis by providing savings plans. Any organization called a large electricity consumer the use of appropriate energy-saving technologies or solutions minimizes energy consumption. Collecting this information provides consumers the idea of improving energy efficiency and reducing costs. Energy control of lighting and management of electrical load audit work was carried out to evaluate energy consumption, therefore energy savings opportunities identified implementing energy-efficient equipment or technologies to be adopted at the institution to minimize the energy consumption. A comparative analysis of the energy flow has been done in ETAP software that uses existing types of equipment and efficient equipment. Effective energy audit process in the college of engineering can focus the employees to think of energy as a controlla...
Process Integration and Optimization for Sustainability
Power flow analysis is the backbone of power system analysis and design. They are necessary for p... more Power flow analysis is the backbone of power system analysis and design. They are necessary for planning, operation, economic scheduling and exchange of power between utilities. The principal information of power flow analysis is to find the magnitude and phase angle of voltage at each bus and the real and reactive power flowing in each transmission lines. Power flow analysis is an importance tool involving numerical analysis applied to a power system. In this analysis a general and procedural algorithm forY matrix building is proposed in this paper. We know that the procedure for obtaining Y bus or Z bus matrices in any frame of reference. Requires matrix transformation involving inversion and multiplications. It Could Be Very Laborious and time consuming process for large system involving hundreds of nodes or buses. Such an algorithm would be very convenient for various large system that may needed while the system is in operation such as addition of line, removal of lines and cha...
The electrical distribution systems are consists of large losses as the loads are wide spread, le... more The electrical distribution systems are consists of large losses as the loads are wide spread, less effective reactive power compensation facilities and their improper control which results in ineffective utilization of electrical energy. In solution of that the investigation is carried on static VAr compensator (SVC) with thyristor binary compensator. The work deals with the analytical studies and implementation of simulation model of static VAr compensator (SVC) at 3Φ, 50Hz, 11kV/440V, DY-11, 500 kVA distribution transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps in conjunction with smallest step size thyristor controlled reactor. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
The harmonic distortion is a very sensitive issue for all power consumers, causes ill-effects suc... more The harmonic distortion is a very sensitive issue for all power consumers, causes ill-effects such as an increase in loss and current and thereby reduce the life of equipment. The non-linear loads such as be personal computers, automatic machines, adjustable speed drives, lighting ballasts and other power electronic equipment are the main sources of harmonics. In this work, the harmonic mitigation was done of a computer laboratory by shunt connected tuned passive filters. Computer loads contains a switched-mode power supply (SMPS) in the system that generates harmonics at the input side of power supply due to non-sinusoidal current. The simulation work was carried out by modeling personal computer load and single tuned passive filter designed by equal and unequal method. The attractive results for harmonic reduction has been observed. Design of shunt passive power harmonic filters by using equal and unequal branch VAR can be a simple and cost-effective technique for the mitigation o...
Electrical distribution systems are incurring large losses as the loads are wide spread, inadequa... more Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. In solution the experimental studies of static VAr compensator (SVC) with thyristor binary compensator is carried out. The work deals with the performance evaluation through analytical studies and implementation of hardware circuit model of SVC at single phase, 50Hz, 2kVA transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
2020 5th International Conference on Communication and Electronics Systems (ICCES), 2020
The three-phase four wires low voltage supply system to residential, commercial and production ar... more The three-phase four wires low voltage supply system to residential, commercial and production areas in the distribution system is implemented. The different nature of loads connected to the three-wire four-phase distribution system. It can be personal computers, automatic machines, variable speed drives, lighting ballasts and other electronic power equipment, which may produce a nonlinear characteristic cause zero sequence current to flow in the system in the neutral of supply system. This may cause a serious power quality problems, results in reduction. This paper present to reduce the harmonics currents and neutral overloading by using the zigzag transformer. The zigzag transformer is one of the solution to attenuate the neutral current and reduce the zero sequence harmonic currents of the distribution systems.
— The electrical distribution systems are consists of large losses as the loads are wide spread, ... more — The electrical distribution systems are consists of large losses as the loads are wide spread, less effective reactive power compensation facilities and their improper control which results in ineffective utilization of electrical energy. In solution of that the investigation is carried on static VAr compensator (SVC) with thyristor binary compensator. The work deals with the analytical studies and implementation of simulation model of static VAr compensator (SVC) at 3Φ, 50Hz, 11kV/440V, DY-11, 500 kVA distribution transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps in conjunction with smallest step size thyristor controlled reactor. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
— Electrical distribution systems are incurring large losses as the loads are wide spread, inadeq... more — Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. In solution the experimental studies of static VAr compensator (SVC) with thyristor binary compensator is carried out. The work deals with the performance evaluation through analytical studies and implementation of hardware circuit model of SVC at single phase, 50Hz, 2kVA transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.
— Electrical distribution systems are incurring large losses as the loads are wide spread, inadeq... more — Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. In solution the experimental studies of static VAr compensator (SVC) with thyristor binary compensator is carried out. The work deals with the performance evaluation through analytical studies and implementation of hardware circuit model of SVC at single phase, 50Hz, 2kVA transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system. Index Terms-reactive power, static VAr compensator, thyristor binary compensator, capacitor bank, binary sequential steps, hardware circuit model, power factor, electrical power system.
— The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It... more — The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It is a variable impedance device where the current through reactor is controlled using bidirectional thyristor valves. The application of SVC is initially for load compensation of fast changing loads. Here the objective is to provide dynamic power factor improvement and also balance the currents on the source side whenever required. The work deals with the analytical studies, modeling and simulation of SVC to make it possible competent compensator of current generation. The investigation is carried out on different configuration of SVCs. The result of that thyristor binary compensator (TBC) type of thyristor switched capacitor (TSC) in conjunction with smallest step size thyristor controlled reactor (TCR) configuration turn out to be best solution over major power quality issues. Keywords—static var compensator, thyristor binary compensator, thyristor switched capacitor, thyristor controlled reactor, power factor, power quality.
— The electrical distribution systems are consists of large losses as the loads are wide spread, ... more — The electrical distribution systems are consists of large losses as the loads are wide spread, less effective reactive power compensation facilities and their improper control which results in ineffective utilization of electrical energy. In solution of that the investigation is carried on static VAr compensator (SVC) with thyristor binary compensator. The work deals with the analytical studies and implementation of simulation model of static VAr compensator (SVC) at 3Φ, 50Hz, 11kV/440V, DY-11, 500 kVA distribution transformer. The SVC consisting of thyristor switched capacitor bank in binary sequential steps in conjunction with smallest step size thyristor controlled reactor. This compensation technique facilitates control on the reactive power depending on load requirement so as maintain power factor near unity always, which results in efficient electrical power system.