New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2: correlation study (original) (raw)
Access this article
Subscribe and save
- Starting from 10 chapters or articles per month
- Access and download chapters and articles from more than 300k books and 2,500 journals
- Cancel anytime View plans
Buy Now
Price excludes VAT (USA)
Tax calculation will be finalised during checkout.
Instant access to the full article PDF.
References
- Alexander, H., Cohen, M. L. andSteinfield, L. S. (1977) Criteria in the choice of an occluding cuff for the indirect measurement of blood pressure.Med. & Biol. Eng. & Comput.,15, 2–10.
Google Scholar - Cox, R. H. (1978) Comparison of carotid artery mechanics in the rat, rabbit and dog.Am. J. Physiol.,234, H280-H288.
Google Scholar - Dobrin, P. B. andRovich, A. A. (1969) Influence of vascular smooth muscle on contractile mechanics and elasticity of arteries.Am. J. Physiol.,217, 1644–1651.
Google Scholar - Geddes, L. A. (1970)The direct and indirect measurement of blood pressure. p. 196, Year Book Medical Publ., Chicago, Illinois.
Google Scholar - Geddes, L. A., Chaffee, V., Whistler, S. J., Bourland, J. D. andTacker, W. A. (1977) Indirect mean blood pressure on the anesthetized pony.Amer. J. Vet. Res.,38, 2055–2057.
Google Scholar - Geddes, L. A., Combs, W., Denton, W., Whistler, S. J. andBourland, J. D. (1980) Indirect mean arterial pressure in the anesthetized dog.Am. J. Physiol.,238, H664-H666.
Google Scholar - Kirkendall, W. M., Burton, A. C. Epstein, F. H. andFreis, E. D. (1967) Recommendations for human blood pressure determination by sphygmomanometers. Report of the Central Committee for Medical and Community Program of the American Heart Association, 3–24.
- Latshaw, H. S., Whistler, S. J., Fessler, J. F. andGeddes, L. A. (1979) Indirect measurement of mean blood pressure in the normotensive and hypotensive horse.Equine Vet. J.,11, 191–194.
Article Google Scholar - Mauck, G. W., Smith, C. R., Geddes, L. A. andBourland J. D. (1980) The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure—Part II.J. Biomech. Eng.,102, 28–33.
Article Google Scholar - Posey, J. A., Geddes, L. A., Williams, H. andMoore, A. G. (1969) The meaning of the, point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure—Part I.Cardiovascular Research Center Bull.,8, 15–25.
Google Scholar - Ramsey, M., III. (1979) Noninvasive automatic determination of mean arterial pressure.Med. & Biol. Eng. & Comput.,17, 11–18.
Google Scholar - Wood, E. H., Knutson, J. R. andTaylor, B. E. (1950) Measurement of blood content and arterial pressure in the human ear.Proc. Staff Meet. Mayo Clin.,25, 398–405.
Google Scholar - Yamakoshi, K., Shimazu, H. andTogawa, T. (1979) Indirect measurement of instantaneous arterial blood pressure in the rat.Am. J. Physiol.,237, H632-H637.
Google Scholar - Yamakoshi, K., Shimazu H. andTogawa T. (1980) Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.IEEE Trans. Biomed. Eng.,BME-27, 150–155.
Google Scholar - Yamakoshi, K., Shimazu, H., Shibata, M. andKamiya, A. (1982) New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger; Part 1. Model experiment.Med. & Biol. Eng. & Comput.,20, 307–313.
Google Scholar - Yelderman, M. andReam, A. (1979) Indirect measurement of mean blood pressure in the anesthetized patient.Anesthesiology,50, 253–256.