A network scanner image management station (original) (raw)

Abstract

Distributed computing can be applied to CT or MRI scanner image acquisition, printing, and archiving by interfacing the scanner with a computer network. Also on the network must be a computer workstation that has image management software to capture the images sent over the network by the scanner. This software must also allow the radiology staff to print and archive the images. Several benefits are realized by this network configuration. First, the scanner console is solely used for scanning patients; delays are not encountered because the console is being used for printing and archiving images. Also, the workstation printing software can be developed so that useful features not available at the scanner console can be incorporated. Finally, sophisticated archiving strategies can be implemented at the workstation. We have developed a network image management station at the Fox Chase Cancer Center using a reduced instruction set computer (RISC) workstation. Hardware and software is utilized to convert all scanner image data to the American College of Radiology-National Electrical Manufacturers Association format. All workstation software is developed using the open X-Windows standard. Digital audio tape is used for image archiving.

Article PDF

Similar content being viewed by others

References

  1. London JW, Morton DE, Polekoff D, et al: The use of X-terminals as clinical workstations. J Med Sys 15:3–9, 1991
    Article CAS Google Scholar
  2. Patterson D: Reduced Instruction Set Computers. Communications of the ACM, 28:8–21, 1985
    Article Google Scholar
  3. Spilker C: The ACR-NEMA Digital imaging and communications standard: A nontechnical description. J Digit Imag 2:127–131, 1989
    CAS Google Scholar
  4. Horii SC, Hill DG, Blume HR, et al: An update on American College of Radiology-National Electrical Manufacturers Association standards activity. J Digit Imag 3:146–151, 1990
    Article CAS Google Scholar
  5. Scheifler RW, Gettys J: The X Window system. ACM Transactions on Graphics 5:79–109, 1986
    Article Google Scholar
  6. London JW: A cluster solution to clinical and research computing needs. Proceedings of the Ninth Annual Symposium on Computer Applications in Medical Care 722–726, 1985
  7. London JW, Morton DE, Polekoff D: A Migration Path to Distributed Clinical Computing, The Fifth Annual Information Technology in the Health Sciences Conference, Memphis, TN, 1990
  8. Silva JS, Zawilski AJ, O’Brian J, et al: The physician workstation: An intelligent “frontend” to a hospital information system. Proceedings of the 14th Annual Symposium on Computer Applications in Medical Care 764–767, 1990
  9. Shortliffe EH, Wulfman CE, Rindfleisch TC, et al: Final report: An integrated oncology workstation. National Cancer Institute, contract NIH 263-89-C-0080, 1990

Download references

Author information

Authors and Affiliations

  1. Fox Chase Cancer Center, 7701 Burholme Ave, 19111, Philadelphia, PA
    Jack W. London PhD & Daniel E. Morton

Authors

  1. Jack W. London PhD
  2. Daniel E. Morton

Rights and permissions

About this article

Cite this article

London, J.W., Morton, D.E. A network scanner image management station.J Digit Imaging 5, 7–13 (1992). https://doi.org/10.1007/BF03167818

Download citation

Key words