Ophir J, Cespedes I, Ponnekanti H, Yazdi T, Li X (1991) Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging 2:111–134 Article Google Scholar
Itoh A, Ueno E, Tohno E, et al. (2006) Breast disease: clinical application of US elastography for diagnosis. Radiology 239:341–350 ArticlePubMed Google Scholar
Lu Q, Wen JX, Huang BJ, Xue LY, Wang WP (2015) Virtual touch quantification using acoustic radiation force impulse (ARFI) technology for the evaluation of focal solid renal lesions: preliminary findings. Clin Radiol 70(12):1376–1381. https://doi.org/10.1016/j.crad.2015.08.002 ArticleCASPubMed Google Scholar
Samir AE, Dhyani M, Vij A, et al. (2015) Shear-wave elastography for the estimation of liver fibrosis in chronic liver disease: determining accuracy and ideal site for measurement. Radiology 274:888–896. https://doi.org/10.1148/radiol.14140839 ArticlePubMed Google Scholar
Park SY, Choi JS, Han BK, Ko EY, Ko ES (2017) Shear wave elastography in the diagnosis of breast non-mass lesions: factors associated with false negative and false positive results. Eur Radiol 9:3788–3798. https://doi.org/10.1007/s00330-017-4763-6 Article Google Scholar
Boehm K, Salomon G, Beyer B, et al. (2015) Shear wave elastography for localization of prostate cancer lesions and assessment of elasticity thresholds: implications for targeted biopsies and active surveillance protocols. J Urol 193:794–800. https://doi.org/10.1016/j.juro.2014.09.100 ArticlePubMed Google Scholar
Samir AE, Dhyani M, Anvari A, et al. (2015) Shear-wave elastography for the preoperative risk stratification of follicular-patterned lesions of the thyroid: diagnostic accuracy and optimal measurement plane. Radiology 277:565–573. https://doi.org/10.1148/radiol.2015141627 ArticlePubMed Google Scholar
Catheline S, Thomas JL, Wu F, Fink MA (1999) Diffraction field of a low frequency vibrator in soft tissues using transient elastography. IEEE Trans Ultrason Ferroelectr Freq Control 4:1013–1019. https://doi.org/10.1109/58.775668 Article Google Scholar
Sandrin L, Tanter M, Gennison JL, Catheline S, Fink M (2002) Shear elasticity probe for soft tissues with 1-D transient elastography. IEEE Trans Ultrason Ferroelectr Freq Control 4:436–446 Article Google Scholar
Sasso M, Beaugrand M, de Ledinghen V, et al. (2010) Controlled attenuation parameter (CAP): a novel VCTE™ guided ultrasonic attenuation measurement for the evaluation of hepatic steatosis: preliminary study and validation in a cohort of patients with chronic liver disease from various causes. Ultrasound Med Biol 36(11):1825–1835. https://doi.org/10.1016/j.ultrasmedbio.2010.07.005 ArticlePubMed Google Scholar
Sandrin L, Fourquet B, Hasquenoph JM, et al. (2003) Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. Ultrasound Med Biol 12:1705–1713 Article Google Scholar
Bercoff J, Tanter M, Fink M (2004) Supersonic shear imaging: a new technique for soft tissue elasticity mapping. IEEE Trans Ultrason Ferroelectr Freq Control 4:396–409 Article Google Scholar
Ferraioli G, Tinelli C, Dal Bello B, et al. (2012) Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Hepatology 56:2125–2133. https://doi.org/10.1002/hep.25936 ArticlePubMed Google Scholar
Fujimoto K, Kato M, Kudo M, et al. (2013) Novel image analysis method using ultrasound elastography for noninvasive evaluation of hepatic fibrosis in patients with chronic hepatitis C. Oncology 84:3–12. https://doi.org/10.1159/000345883 ArticlePubMed Google Scholar
Koizumi Y, Hirooka M, Kisaka Y, et al. (2011) Liver fibrosis in patients with chronic hepatitis C: noninvasive diagnosis by means of real-time tissue elastography—establishment of the method for measurement. Radiology 2:610–617. https://doi.org/10.1148/radiol.10100319 Article Google Scholar
Onur MR, Poyraz AK, Ucak EE, et al. (2012) Semiquantitative strain elastography of liver masses. J Ultrasound Med 7:1061–1067 Article Google Scholar
Li Y, Huang YS, Wang ZZ, et al. (2016) Systematic review with meta-analysis: the diagnostic accuracy of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B. Aliment Pharmacol Ther 43:458–469. https://doi.org/10.1111/apt.13488 ArticleCASPubMed Google Scholar
Ying HY, Lu LG, Jing DD, Ni XS (2016) Accuracy of transient elastography in the assessment of chronic hepatitis C-related liver cirrhosis. Clin Invest Med 39(5):E150–E160 ArticlePubMed Google Scholar
Pavlov CS, Casazza G, Nikolova D, Tsochatzis E, Gluud C (2016) Systematic review with meta-analysis: diagnostic accuracy of transient elastography for staging of fibrosis in people with alcoholic liver disease. Aliment Pharmacol Ther 43:575–585. https://doi.org/10.1111/apt.13524 ArticleCASPubMed Google Scholar
Fraquelli M, Rigamonti C, Casazza G, et al. (2007) Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease. Gut 56:968–973 ArticlePubMedPubMed Central Google Scholar
Tachi Y, Hirai T, Kojima Y, et al. (2016) Liver stiffness measurement using acoustic radiation force impulse elastography in hepatitis C virus-infected patients with a sustained virological response. Aliment Pharmacol Ther 44:346–355. https://doi.org/10.1111/apt.13695 ArticleCASPubMed Google Scholar
Cao W, Zhou Y, Niu Y, et al. (2017) Quantitative analysis of hepatic toxicity in rats induced by inhalable silica nanoparticles using acoustic radiation force imaging. J Ultrasound Med 36(9):1829–1839. https://doi.org/10.1002/jum.14219 ArticlePubMed Google Scholar
Hu X, Qiu L, Liu D, Qian L (2017) Acoustic radiation force impulse (ARFI) elastography for non-invasive evaluation of hepatic fibrosis in chronic hepatitis B and C patients: a systematic review and meta-analysis. Med Ultrason 19:23–31. https://doi.org/10.11152/mu-942 ArticlePubMed Google Scholar
Jaffer OS, Lung PFC, Bosanac D, et al. (2012) Acoustic radiation force impulse quantification: repeatability of measurements in selected liver segments and influence of age, body mass index and liver capsule-to-box distance. BJR 85:e858–e863. https://doi.org/10.1259/bjr/74797353 ArticleCASPubMedPubMed Central Google Scholar
Balakrishnan M, Souza F, Muñoz C, et al. (2016) Liver and spleen stiffness measurements by point shear wave elastography via acoustic radiation force impulse. J Ultrasound Med 35:2373–2380 ArticlePubMed Google Scholar
Dhyani M, Gee MS, Misdraji J, et al. (2015) Feasibility study for assessing liver fibrosis in paediatric and adolescent patients using real-time shear wave elastography. J Med Imaging Radiat Oncol 59(6):687–694. https://doi.org/10.1111/1754-9485.12388 ArticlePubMed Google Scholar
Cui G, Yang Z, Zhang W, et al. (2014) Evaluation of acoustic radiation force impulse imaging for the clinicopathological typing of renal fibrosis. Exp Ther Med 7(1):233–235 ArticlePubMed Google Scholar
Bob F, Bota S, Sporea I, et al. (2014) Kidney shear wave speed values in subjects with and without renal pathology and inter-operator reproducibility of acoustic radiation force impulse elastography (ARFI): preliminary results. PLoS ONE 9(11):e113761 ArticlePubMedPubMed CentralCAS Google Scholar
Bota S, Bob F, Sporea I, Şirli R, Popescu A (2015) Factors that influence kidney shear wave speed assessed by acoustic radiation force impulse elastography in patients without kidney pathology. Ultrasound Med Biol 41(1):1–6 ArticlePubMed Google Scholar
Wang L (2016) Applications of acoustic radiation force impulse quantification in chronic kidney disease: a review. Ultrasonography 35(4):302–308 ArticleCASPubMedPubMed Central Google Scholar
Hassan K, Loberant N, Abbas N, et al. (2016) Shear wave elastography imaging for assessing the chronic pathologic changes in advanced diabetic kidney disease. Ther Clin Risk Manag 12:1615–1622 ArticlePubMedPubMed Central Google Scholar
Li DD, Guo LH, Xu HX, et al. (2015) Acoustic radiation force impulse elastography for differentiation of malignant and benign breast lesions: a meta-analysis. Int J Clin Exp Med 8(4):4753–4761 PubMedPubMed Central Google Scholar
Woo S, Kim SY, Cho JY, Kim SH (2014) Shear wave elastography for detection of prostate cancer: a preliminary study. Korean J Radiol 3:346–355 Article Google Scholar
Brock M, von Bodman C, Palisaar RJ, et al. (2012) The impact of real-time elastography guiding a systematic prostate biopsy to improve cancer detection rate: a prospective study of 353 patients. J Urol 187:2039–2043. https://doi.org/10.1016/j.juro.2012.01.063 ArticlePubMed Google Scholar
Zheng X, Ji P, Mao H, Hu J (2012) A comparison of virtual touch tissue quantification and digital rectal examination for discrimination between prostate cancer and benign prostatic hyperplasia. Radiol Oncol 46(1):69–74. https://doi.org/10.2478/v10019-011-0026-3 ArticlePubMed Google Scholar
Woo S, Suh CH, Kim SY, Cho JY, Kim SH (2017) Shear-wave elastography for detection of prostate cancer: a systematic review and diagnostic meta-analysis. Am J Roentgenol 4:806–814. https://doi.org/10.2214/AJR.17.18056 Article Google Scholar
Zhang M, Fu S, Zhang Y, Tang J, Zhou Y (2013) Elastic modulus of the prostate: a new non-invasive feature to diagnose bladder outlet obstruction in patients with benign prostatic hyperplasia. Ultrasound Med Biol 40(7):1408–1413. https://doi.org/10.1016/j.ultrasmedbio.2013.10.012 Article Google Scholar
Bojunga J, Herrmann E, Meyer G, et al. (2010) Real-time elastography for the differentiation of benign and malignant thyroid nodules: a meta-analysis. Thyroid 2010(20):1145–1150. https://doi.org/10.1089/thy.2010.0079 Article Google Scholar
Liu B, Liang J, Zheng Y, et al. (2015) Two-dimensional shear wave elastography as promising diagnostic tool for predicting malignant thyroid nodules: a prospective single-centre experience. Eur Radiol 25:624–634. https://doi.org/10.1007/s00330-014-3455-8 ArticlePubMed Google Scholar
Zhang F, Zhao X, Han R, et al. (2017) Comparison of acoustic radiation force impulse imaging and strain elastography in differentiating malignant from benign thyroid nodules. J Ultrasound Med. https://doi.org/10.1002/jum.14302 Google Scholar
Deng J, Zhou P, Tian SM, et al. (2014) Comparison of diagnostic efficacy of contrast-enhanced ultrasound, acoustic radiation force impulse imaging, and their combined use in differentiating focal solid thyroid nodules. PLoS ONE 3:e90674. https://doi.org/10.1371/journal.pone.0090674 Article Google Scholar
Rustemović N, Kalauz M, Grubelić Ravić K, et al. (2017) Differentiation of pancreatic masses via endoscopic ultrasound strain ratio elastography using adjacent pancreatic tissue as the reference. Pancreas 3:347–351. https://doi.org/10.1097/MPA.0000000000000758 Article Google Scholar
Kim SY, Cho JH, Kim YJ, et al. (2017) Diagnostic efficacy of quantitative endoscopic ultrasound elastography for differentiating pancreatic disease. J Gastroenterol Hepatol 5:1115–1122. https://doi.org/10.1111/jgh.13649 Article Google Scholar
Iglesias-Garcia J, Domínguez-Muñoz JE, Castiñeira-Alvariño M, Luaces-Regueira M, Lariño-Noia J (2013) Quantitative elastography associated with endoscopic ultrasound for the diagnosis of chronic pancreatitis. Endoscopy 10:781–788. https://doi.org/10.1055/s-0033-1344614 Google Scholar
Park MK, Jo J, Kwon H, et al. (2014) Usefulness of acoustic radiation force impulse elastography in the differential diagnosis of benign and malignant solid pancreatic lesions. Ultrasonography 33:26–33. https://doi.org/10.14366/usg.13017 ArticlePubMed Google Scholar
Pozzi R, Parzanese I, Baccarin A, et al. (2017) Point shear-wave elastography in chronic pancreatitis: a promising tool for staging disease severity. Pancreatology 17:905–910 ArticlePubMed Google Scholar
Mateen MA, Muheet KA, Mohan RJ, et al. (2012) Evaluation of ultrasound based acoustic radiation force impulse (ARFI) and eSie touch sonoelastography for diagnosis of inflammatory pancreatic diseases. JOP 13(1):36–44 PubMed Google Scholar
Takuma Y, Nouso K, Morimoto Y, et al. (2013) Measurement of spleen stiffness by acoustic radiation force impulse imaging identifies cirrhotic patients with esophageal varices. Gastroenterology 1:92–101. https://doi.org/10.1053/j.gastro.2012.09.049 Article Google Scholar
Grgurevic I, Bokun T, Mustapic S, et al. (2015) Real-time two-dimensional shear wave ultrasound elastography of the liver is a reliable predictor of clinical outcomes and the presence of esophageal varices in patients with compensated liver cirrhosis. Croat Med J. 56:470–481. https://doi.org/10.3325/cmj.2015.56.470 ArticleCASPubMedPubMed Central Google Scholar
Kim TY, Kim TY, Kim Y, et al. (2016) Diagnostic performance of shear wave elastography for predicting esophageal varices in patients with compensated liver cirrhosis. J Ultrasound Med 35:1373–1381 ArticlePubMed Google Scholar
Elkrief L, Rautou PE, Ronot M, et al. (2015) Prospective comparison of spleen and liver stiffness by using shear-wave and transient elastography for detection of portal hypertension in cirrhosis. Radiology 275(2):589–598. https://doi.org/10.1148/radiol.14141210 ArticlePubMed Google Scholar
Barr Richard G (2017) Principles of elastography. In: Barr RG (ed) Elastography: a practical approach, 1st edn. New York: Thieme, pp 6–24 Google Scholar
Arena U, Vizzutti F, Corti G, et al. (2008) Acute viral hepatitis increases liver stiffness values measured by transient elastography. Hepatology 47:380–384 ArticleCASPubMed Google Scholar
Stevenson M, Lloyd-Jones M, Morgan MY, Wong R (2012) Non-invasive diagnostic assessment tools for the detection of liver fibrosis in patients with suspected alcohol-related liver disease: a systematic review and economic evaluation. Health Technol Assess 16:1–194. https://doi.org/10.3310/hta16040 ArticleCASPubMed Central Google Scholar
Barr RG, Zhang Z (2012) Effects of precompression on elasticity imaging of the breast: development of a clinically useful semiquantitative method of precompression assessment. J Ultrasound Med 31(6):895–902 ArticlePubMed Google Scholar
Hong Y, Liu X, Li Z, et al. (2009) Real-time ultrasound elastography in the differential diagnosis of benign and malignant thyroid nodules. J Ultrasound Med 28:861–867 ArticlePubMed Google Scholar
Early H, Aguilera J, Cheang E, McGahan J (2017) Challenges and considerations when using shear wave elastography to evaluate the transplanted kidney, with pictorial review. J Ultrasound Med 36(9):1771–1782. https://doi.org/10.1002/jum.14217 ArticlePubMed Google Scholar