A modified medical image registration (original) (raw)
Abstract
Medical image registration is commonly used in clinical diagnosis, treatment, quality assurance, evaluation of curative efficacy and so on. In this paper, the edges of the original reference and floating images are detected by the B-spline gradient operator and then the binarization images are acquired. By computing the binarization image moments, the centroids are obtained. Also, according to the binarization image coordinates, the rotation angles of the reference and floating images are computed respectively, on the foundation of which the initial values for registering the images are produced. When searching the optimal geometric transformation parameters, the modified peak signal-to-noise ratio (MPSNR) is viewed as the similarity metric between the reference and floating images. At the same time, the simplex method is chosen as multi-parameter optimization one. The experimental results show that, this proposed method has a fairly simple implementation, a low computational load, a fast registration and good registration accuracy. It also can effectively avoid trapping in the local optimum and is adapted to both mono-modality and multi-modality image registrations. Also, the improved iterative closest point algorithm based on acquiring the initial values for registration from the least square method (LICP) is introduced. The experiments reveal that the measure acquiring the initial values for registration from image moments and the least square method (LSM) is feasible and resultful strategy.
Access this article
Subscribe and save
- Starting from 10 chapters or articles per month
- Access and download chapters and articles from more than 300k books and 2,500 journals
- Cancel anytime View plans
Buy Now
Price excludes VAT (USA)
Tax calculation will be finalised during checkout.
Instant access to the full article PDF.
Similar content being viewed by others
References
- Bergevin R, Soucy M, Gagnon H et al (1996) Towards a general multi-view registration technique. IEEE Trans Pattern Anal Mach Intell 18(5):540–547
Article Google Scholar - Besl PJ, Mckay ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14(2):239–256
Article Google Scholar - Blondel C, Vaillant R, Malandain G et al (2004) 3D tomographic reconstruction of coronary arteries using a precomputed 4D motion field. Phys Med Biol 49(11):2197–2208
Article Google Scholar - Borgefors G (1988) Hierarchical chamfer matching: a parametric edge matching algorithm. IEEE Trans Pattern Anal Mach Intell 10(6):849–865
Article Google Scholar - Brown L (1992) A survey of image registration techniques. ACM Comput Surv 24(4):325–376
Article Google Scholar - Can A, Stewart C (2002) A feature-based, robust, hierarchical algorithm for registration palm of images of the curved human retina. IEEE Trans Pattern Anal Mach Intell 24(3):347–363
Article Google Scholar - Chen Y, Medioni G (1992) Object Modeling by Registration of Multiple Range Images. Imag Vis Comput 10(3):145–155
Article Google Scholar - Fei B, Wheaton A, Lee Z et al (2002) Automatic MR volume registration and its evaluation for the pelvis and prostate. Phys Med Biol 47(5):823–838
Article Google Scholar - Gelfand N, Ikemoto L, Rusinkiewicz S, et al. (2003) Geometrically Stable Sampling for the ICP Algorithm. Proceedings of the 4th International Conference on 3-D Digital Imaging and Modeling. Stanford University, CA, USA, 260–267
- Hu M (1962) Visual pattern recognition by moment invariants. IRE Trans Inform Theory 8:179–187
MATH Google Scholar - Hyunjin P, Peyton H, Kristy K et al (2004) Adaptive registration using local information measures. Med Image Anal 8(4):465–473
Article Google Scholar - Krucker JF, LeCarpentier GL, Fowlkes JB et al (2002) Rapid elastic image registration for 3-D ultrasound. IEEE Trans Med Imag 21(11):1384–1394
Article Google Scholar - Kybic J, Unser M (2003) Fast parametric elastic image registration. IEEE Trans Image Process 12(11):1427–1442
Article Google Scholar - Lehmann TM, Gonner C, Spitzer K (1999) Survey: Interpolation Methods in Medical Image Processing. IEEE Trans Med Imaging 18(11):1049–1075
Article Google Scholar - Lu ZT, Feng YQ, Feng QJ et al (2008) Medical Image Registration Based on Principal Phase Congruency. Acta Electronica Sinica 36(10):1974–1978
Google Scholar - Maes F, Collignon A, Vandermeulen D et al (1997) Multimodality image registration by maximization of mutual information. IEEE Trans Med Imag 16(2):187–198
Article Google Scholar - Maintz JBA, Viergever MA (1998) A survey of medical image registration. Med Image Anal 2(1):1–36
Article Google Scholar - Pan MS, Tang JT, Yang XL (2011) Medical Image Registration Based on SVD and Modified PSNR. J Inf Sci Eng 27(5):1761–1775
MATH MathSciNet Google Scholar - Park SY, Subbarao M (2004) Automatic 3D model reconstruction based on novel pose estimation and integration techniques. Imag Vis Comput 22(8):623–635
Article Google Scholar - Paul V, William M, Wells I (1997) Alignment by Maximization of Mutual Information. Int J Comput Vis 24(2):137–154
Article Google Scholar - Pluim JPW, Maintz JBA, Viergever MA (2003) Mutual-information-based registration of medical Images: A Survey. IEEE Trans Med Imaging 22(8):986–1004
Article Google Scholar - Radau PE, Slomka PJ, Julin P et al (2001) Evaluation of linear registration algorithm for brain SPECT and the errors due to hypoperfusion lesions. Med Phys 28(8):1660–1668
Article Google Scholar - Rueckert D, Sonoda L, Hayes C et al (1999) Nonrigid registration using free-form deformations:application to breast MR images. IEEE Trans Med Imag 18(8):712–721
Article Google Scholar - Rusinkiewicz S, Levoy M (2001) Efficient variants of the ICP algorithm. Proceedings of the 3rd International Conference on 3-D Digital Imaging and Modeling, Quebec, 145–152
- Saber E, Tekalp AM (1997) Region-Based Shape Matching for Automatic Image Annotation and Query-by-Example. J Vis Comm Image Represent 8(1):3–20
Article Google Scholar - Slomka PJ, Mandel J, Downey D et al (2001) Evaluation of voxel-based registration of 3-D power doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries. Ultrasound Med Biol 27(7):945–955
Article Google Scholar - Stammberger T, Eckstein F, Michaelis M et al (1999) Interobserver reproducibility of quantitative cartilage measurements: comparison of B-spline snakes and manual segmentation. Magn Reson Imag 17(7):1033–1042
Article Google Scholar - Staring M, Klein S, Pluim JPW (2007) Nonrigid registration with tissue-dependent filtering of the deformation field. Phys Med Biol 52(23):6879–6892
Article Google Scholar - Szeliski R, Coughlan J (1997) Spline-based image registration. Int J Comput Vis 22(3):199–218
Article Google Scholar - Thevenaz P, Unser M (2000) Optimization of mutual information for multiresolution image registration. IEEE Trans Image Process 9(12):2083–2099
Article MATH Google Scholar - Unser M (1999) Spline: A perfect fit for signal and image processing. IEEE Signal Process 16(8):22–38
Article Google Scholar - Unser M, Aldroubi A, Eden M (1993) B-spline Signal Processing: Part-I Theory. IEEE Trans Signal Process 41(2):821–833
Article MATH Google Scholar - Unser M, Aldroubi A, REden M (1993) B-spline Signal Processing: Part-II Theory. IEEE Trans Signal Process 41(2):834–848
Article MATH Google Scholar
Acknowledgement
This paper was partially supported by the Key Discipline-Leader Foundation of Hunan Provincial Institutions of Higher Education, PRC and supported by Outstanding Young Scientific Research Fund of Hunan Provincial Education Department, PRC(No.09B071).
Author information
Authors and Affiliations
- College of Computer Science and Technology, Hunan University of Arts and Science, Changde, 415000, Hunan Province, People’s Republic of China
Mei-sen Pan, Qiu-sheng Rong, Fen Zhang, Hui-can Zhou & Fang-yan Nie - Library of Hunan University of Arts and Science, Changde, 415000, Hunan Province, People’s Republic of China
Jian-jun Jiang
Authors
- Mei-sen Pan
- Jian-jun Jiang
- Qiu-sheng Rong
- Fen Zhang
- Hui-can Zhou
- Fang-yan Nie
Corresponding author
Correspondence toMei-sen Pan.
Rights and permissions
About this article
Cite this article
Pan, Ms., Jiang, Jj., Rong, Qs. et al. A modified medical image registration.Multimed Tools Appl 70, 1585–1615 (2014). https://doi.org/10.1007/s11042-012-1180-3
- Published: 28 July 2012
- Issue date: June 2014
- DOI: https://doi.org/10.1007/s11042-012-1180-3