@pablogsal, sorry i failed to rebase to main, so i recreated https://github.com/python/cpython/pull/22190GH-issuecomment-1024633392

PyRun_InteractiveOne*() functions allow to explicitily set fd instead of stdin.
but stdin was hardcoded in readline call.

This patch does not fix target file for prompt unlike original bpo one : prompt fd is unrelated to tokenizer source which could be read only. It is more of a bugfix regarding the docs : actual documentation say "prompt the user" so one would expect prompt to go on stdout not a file for both PyRun_InteractiveOne*() and PyRun_InteractiveLoop*().

Automerge-Triggered-By: GH:pablogsal
(cherry picked from commit 89b1304)

Co-authored-by: Paul m. p. P mail.peny@free.fr

https://bugs.python.org/issue14916