Research paper thumbnail of Combination of congenital optic never coloboma in one eye and congenital choroidal coloboma in the fellow eye

Ophthalmology Reports, 2017

The article presents an interesting and fairly rare clinical case of congenital posterior segment... more The article presents an interesting and fairly rare clinical case of congenital posterior segment anomaly of both eyes manifesting itself by coloboma of the optic nerve head in the right eye and choroidal coloboma in the left eye. For the first time, this pathology was diagnosed in our female patient at the age of 48.

Research paper thumbnail of Computer perimetry in the diagnosis of primary open-angle glaucoma

Ophthalmology Reports, 2018

Static perimetry, made using Humphrey and Octopus expert class perimeters, is called the standard... more Static perimetry, made using Humphrey and Octopus expert class perimeters, is called the standard automated perimetry (SAP); and for more than 30 years, it is the gold standard in assessing the visual field in glaucoma diagnosis. Currently, many computer perimeters appeared on the Russian market. The article reviews modern methods of computerized perimetry which are most widespread in our country and presents their comparative characteristics.

Research paper thumbnail of Some aspects of the comparative characteristics of different computerized perimetry methods

Ophthalmologic vedomosti, 2015

Purpose - to compare the ease of use, the comfort for persons to be tested, the examination rate,... more Purpose - to compare the ease of use, the comfort for persons to be tested, the examination rate, as well as the variability of repeated results obtained using four methods of computerized perimetry. Materials and methods. This clinical study included three groups of patients with open-angle glaucoma (OAG). The 1st group included patients with OAG stage I, the 2nd group - with OAG stage II, the 3rd group - with OAG stage III. The control group included healthy individuals. All tested persons underwent examinations by 4 computerized methods (HFA II, Tomey AP-1000, Pericom, and the FDT-perimetry modification developed at the Ophthalmology Department of the Military Medical Academy). Results. FDT-perimetry appeared to be the shortest, easiest test and most comfortable for tested persons. Perimetry using Tomey AP-1000, Pericom and HFA II was more time-consuming and more difficult to perform. Repeated results of all four methods were better than the first one due to the “learning curve” ...

Research paper thumbnail of Rare case of refractive anomaly from clinical practice

Ophthalmology Reports, 2013

The rare case of interior lenticonus is described in this article. Authors consider that an inter... more The rare case of interior lenticonus is described in this article. Authors consider that an interior lenticonus is the cause of development high myopia and compound myopic astigmatism.

Research paper thumbnail of Combination of congenital optic never coloboma in one eye and congenital choroidal coloboma in the fellow eye

Ophthalmology Reports, 2017

The article presents an interesting and fairly rare clinical case of congenital posterior segment... more The article presents an interesting and fairly rare clinical case of congenital posterior segment anomaly of both eyes manifesting itself by coloboma of the optic nerve head in the right eye and choroidal coloboma in the left eye. For the first time, this pathology was diagnosed in our female patient at the age of 48.

Research paper thumbnail of Computer perimetry in the diagnosis of primary open-angle glaucoma

Ophthalmology Reports, 2018

Static perimetry, made using Humphrey and Octopus expert class perimeters, is called the standard... more Static perimetry, made using Humphrey and Octopus expert class perimeters, is called the standard automated perimetry (SAP); and for more than 30 years, it is the gold standard in assessing the visual field in glaucoma diagnosis. Currently, many computer perimeters appeared on the Russian market. The article reviews modern methods of computerized perimetry which are most widespread in our country and presents their comparative characteristics.

Research paper thumbnail of Some aspects of the comparative characteristics of different computerized perimetry methods

Ophthalmologic vedomosti, 2015

Purpose - to compare the ease of use, the comfort for persons to be tested, the examination rate,... more Purpose - to compare the ease of use, the comfort for persons to be tested, the examination rate, as well as the variability of repeated results obtained using four methods of computerized perimetry. Materials and methods. This clinical study included three groups of patients with open-angle glaucoma (OAG). The 1st group included patients with OAG stage I, the 2nd group - with OAG stage II, the 3rd group - with OAG stage III. The control group included healthy individuals. All tested persons underwent examinations by 4 computerized methods (HFA II, Tomey AP-1000, Pericom, and the FDT-perimetry modification developed at the Ophthalmology Department of the Military Medical Academy). Results. FDT-perimetry appeared to be the shortest, easiest test and most comfortable for tested persons. Perimetry using Tomey AP-1000, Pericom and HFA II was more time-consuming and more difficult to perform. Repeated results of all four methods were better than the first one due to the “learning curve” ...

Research paper thumbnail of Rare case of refractive anomaly from clinical practice

Ophthalmology Reports, 2013

The rare case of interior lenticonus is described in this article. Authors consider that an inter... more The rare case of interior lenticonus is described in this article. Authors consider that an interior lenticonus is the cause of development high myopia and compound myopic astigmatism.