Añil Patidar - Academia.edu (original) (raw)

Añil Patidar

Related Authors

Robert J Lake

Kyle Whyte

Gözde Ersöz

Sylvester Olubolu Orimaye

Diego Villar

Diego Villar

National Scientific and Technical Research Council

Rui Biscaia

Ashok Paranjothi

Zoe Todd

Reynier Ortega Bueno

Uploads

Papers by Añil Patidar

Research paper thumbnail of Extended Cross-Layer Jamming Detection and Mitigation in Wireless Broadcast Networks

Indian Journal of Applied Research, 2011

Research paper thumbnail of Behaviour of Concrete Filled Rectangular Steel Tube Column

IOSR Journal of Mechanical and Civil Engineering, 2012

The Concrete Filled Steel Tube (CFST) member has many advantages compared with the conventional c... more The Concrete Filled Steel Tube (CFST) member has many advantages compared with the conventional concrete structural member made of steel reinforcement. CFSTs are frequently used for columns, caissons and for piers, deep foundations because of their large compressive stiffness. The FEA modeling using ANSYS software is adopted to investigate the load versus lateral deflection behavior of the composite sections. The effects of steel tube thickness and strength of in-filled concrete tubes are examined. The size of the column is 140 x 160 x 1500 mm and the grades of concrete infill are M20, M30 and M40. The thickness of the tube is taken as 2 mm, 3 mm, 4 mm, 5 mm and 6 mm and, the D/t ratio varies from 26.67 to 80.00.

Research paper thumbnail of Extended Cross-Layer Jamming Detection and Mitigation in Wireless Broadcast Networks

Indian Journal of Applied Research, 2011

Research paper thumbnail of Behaviour of Concrete Filled Rectangular Steel Tube Column

IOSR Journal of Mechanical and Civil Engineering, 2012

The Concrete Filled Steel Tube (CFST) member has many advantages compared with the conventional c... more The Concrete Filled Steel Tube (CFST) member has many advantages compared with the conventional concrete structural member made of steel reinforcement. CFSTs are frequently used for columns, caissons and for piers, deep foundations because of their large compressive stiffness. The FEA modeling using ANSYS software is adopted to investigate the load versus lateral deflection behavior of the composite sections. The effects of steel tube thickness and strength of in-filled concrete tubes are examined. The size of the column is 140 x 160 x 1500 mm and the grades of concrete infill are M20, M30 and M40. The thickness of the tube is taken as 2 mm, 3 mm, 4 mm, 5 mm and 6 mm and, the D/t ratio varies from 26.67 to 80.00.

Log In