Avinash Joshi - Academia.edu (original) (raw)
Papers by Avinash Joshi
Toxicon, 1972
1. Toxicon. 1972 Jan;10(1):89-91. Toxicity to rats and mice of purified phytohaemagglutinins from... more 1. Toxicon. 1972 Jan;10(1):89-91. Toxicity to rats and mice of purified phytohaemagglutinins from four Indian legumes. Manage L, Joshi A, Sohonie K. PMID: 5015549 [PubMed - indexed for MEDLINE]. MeSH Terms. Animals; ...
Abstract This paper proposes a novel switched-boost converter suitable for microgrid application.... more Abstract This paper proposes a novel switched-boost converter suitable for microgrid application. The proposed converter can provide a DC output, which is greater than the input voltage. Apart from a DC, it can be, simultaneously, used to supply an AC load. In order to ...
IEEE Transactions on Industry Applications, 1981
In this paper a cascaded H-bridge inverter topology is used in a distribution static compensator ... more In this paper a cascaded H-bridge inverter topology is used in a distribution static compensator (DSTATCOM). A new multiband hysteresis algorithm is used to control the switches of the cascaded H-bridges leading to multilevel output of the inverter. The algorithm requires hierarchal switching of each H-bridge. Sequential change in the hierarchy facilitates equal charging and discharging of each capacitor. This leads to self-balancing of voltage across the capacitors. The multiband hysteresis algorithm is robust even under unequal capacitor voltages due to the dissimilarity in the H-bridge and capacitor units. The use of a resonant controller provides good tracking of the fundamental component of reference current. Discrete sampling of the switching function limits the switching frequency of the semiconductor devices. A 7-level cascaded inverter topology is considered for shunt compensation of an 11-kV distribution system. The results are validated through PSCAD/EMTDC simulation software
Electric Power Systems Research, 2005
This paper describes a few different topologies of inverters used for realizing a distribution st... more This paper describes a few different topologies of inverters used for realizing a distribution static compensator (DSTATCOM). A brief introduction of the need for shunt compensation as well as the requirements of the shunt compensator has also been given. An algorithm for ...
IEEE Transactions on Power Delivery, 2003
IEEE Transactions on Power Delivery, 2007
AbstractIn this paper, load compensation using multilevel inverter-based distribution static com... more AbstractIn this paper, load compensation using multilevel inverter-based distribution static compensator (DSTATCOM) is presented. The DSTATCOM is connected to a three-phase four-wire (3p4w) distribution system. Two different multilevel inverter topologies are used ...
Electric Power Systems Research, 2000
Series capacitive compensation in ac transmission systems can yield several benefits such as incr... more Series capacitive compensation in ac transmission systems can yield several benefits such as increased power transfer capability and enhancement of transient stability. However, the extent to which a transmission line can be compensated with conventional series capacitance is ...
IEEE Transactions on Power Delivery, 2005
AbstractThe flying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter to... more AbstractThe flying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topology intended for high-power and high-voltage operations at low distortion. It uses capacitors, called flying capacitors, to clamp the voltage across the power semiconductor devices. A method ...
IEEE Transactions on Power Delivery, 2007
AbstractFlying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topolo... more AbstractFlying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topology intended for high voltage and power operations with low distortion. It uses capacitors, called flying capacitors for clamping the voltage across the power semiconductor devices. In this ...
Electric Power Systems Research, 2005
The paper discusses the operation and control algorithms of shunt and series active filters. Perf... more The paper discusses the operation and control algorithms of shunt and series active filters. Performance of each of these filters is studied separately when it is connected to protect sensitive loads in a power distribution system. It is assumed that the distribution system is polluted due to ...
IEEE Transactions on Industrial Electronics, 2008
IEEE Transactions on Power Electronics, 2008
AbstractThis paper focuses on the development of multilevel hysteresis current regulation strate... more AbstractThis paper focuses on the development of multilevel hysteresis current regulation strategies. Two such strategies have been discussed and some modifications in their control tasks have been proposed to achieve more reliable and improved perfor-mance. In ...
IEEE Transactions on Power Delivery, 2003
IEEE Transactions on Power Delivery, 2007
IEEE Transactions on Power Delivery, 2000
Abstract This paper presents a new approach for generating reference currents for an active filte... more Abstract This paper presents a new approach for generating reference currents for an active filter and/or a static compensator. It is assumed that the compensator is connected to a load that may either be connected in star or in delta. The load can be unbalanced and may also ...
The paper proposes a new topology of STATCOM that is capable of supplying AC and DC loads in 3-ph... more The paper proposes a new topology of STATCOM that is capable of supplying AC and DC loads in 3-phase 4-wire distribution systems. In this, the authors utilize the method of instantaneous symmetrical components to extract the compensator reference currents that are then tracked in a hysteresis band current control mode. A suitable state space model of the STATCOM is derived. Based on this model, a single cycle control strategy is proposed and is shown to compensate for the drift in capacitor voltages due to DC components of load currents. The operation of the compensator has been verified through MATLAB simulation and detailed simulation results are given
IEEE Transactions on Power Delivery, 2004
Abstract The paper discusses the operating principles and control characteristics of a dynamic vo... more Abstract The paper discusses the operating principles and control characteristics of a dynamic voltage restorer (DVR) that protects sensitive but unbalanced and/or distorted loads. The main aim of the DVR is to regulate the voltage at the load terminal irrespective ...
IEEE Transactions on Power Delivery, 2007
IEEE Transactions on Power Delivery, 2004
AbstractThe paper discusses the concept of a mini custom power park in which the voltage inside ... more AbstractThe paper discusses the concept of a mini custom power park in which the voltage inside the park is tightly regulated by a distribution static compensator (DSTATCOM). It will be shown on the basis of simulations with ideal components that solid state protection ...
Toxicon, 1972
1. Toxicon. 1972 Jan;10(1):89-91. Toxicity to rats and mice of purified phytohaemagglutinins from... more 1. Toxicon. 1972 Jan;10(1):89-91. Toxicity to rats and mice of purified phytohaemagglutinins from four Indian legumes. Manage L, Joshi A, Sohonie K. PMID: 5015549 [PubMed - indexed for MEDLINE]. MeSH Terms. Animals; ...
Abstract This paper proposes a novel switched-boost converter suitable for microgrid application.... more Abstract This paper proposes a novel switched-boost converter suitable for microgrid application. The proposed converter can provide a DC output, which is greater than the input voltage. Apart from a DC, it can be, simultaneously, used to supply an AC load. In order to ...
IEEE Transactions on Industry Applications, 1981
In this paper a cascaded H-bridge inverter topology is used in a distribution static compensator ... more In this paper a cascaded H-bridge inverter topology is used in a distribution static compensator (DSTATCOM). A new multiband hysteresis algorithm is used to control the switches of the cascaded H-bridges leading to multilevel output of the inverter. The algorithm requires hierarchal switching of each H-bridge. Sequential change in the hierarchy facilitates equal charging and discharging of each capacitor. This leads to self-balancing of voltage across the capacitors. The multiband hysteresis algorithm is robust even under unequal capacitor voltages due to the dissimilarity in the H-bridge and capacitor units. The use of a resonant controller provides good tracking of the fundamental component of reference current. Discrete sampling of the switching function limits the switching frequency of the semiconductor devices. A 7-level cascaded inverter topology is considered for shunt compensation of an 11-kV distribution system. The results are validated through PSCAD/EMTDC simulation software
Electric Power Systems Research, 2005
This paper describes a few different topologies of inverters used for realizing a distribution st... more This paper describes a few different topologies of inverters used for realizing a distribution static compensator (DSTATCOM). A brief introduction of the need for shunt compensation as well as the requirements of the shunt compensator has also been given. An algorithm for ...
IEEE Transactions on Power Delivery, 2003
IEEE Transactions on Power Delivery, 2007
AbstractIn this paper, load compensation using multilevel inverter-based distribution static com... more AbstractIn this paper, load compensation using multilevel inverter-based distribution static compensator (DSTATCOM) is presented. The DSTATCOM is connected to a three-phase four-wire (3p4w) distribution system. Two different multilevel inverter topologies are used ...
Electric Power Systems Research, 2000
Series capacitive compensation in ac transmission systems can yield several benefits such as incr... more Series capacitive compensation in ac transmission systems can yield several benefits such as increased power transfer capability and enhancement of transient stability. However, the extent to which a transmission line can be compensated with conventional series capacitance is ...
IEEE Transactions on Power Delivery, 2005
AbstractThe flying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter to... more AbstractThe flying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topology intended for high-power and high-voltage operations at low distortion. It uses capacitors, called flying capacitors, to clamp the voltage across the power semiconductor devices. A method ...
IEEE Transactions on Power Delivery, 2007
AbstractFlying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topolo... more AbstractFlying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topology intended for high voltage and power operations with low distortion. It uses capacitors, called flying capacitors for clamping the voltage across the power semiconductor devices. In this ...
Electric Power Systems Research, 2005
The paper discusses the operation and control algorithms of shunt and series active filters. Perf... more The paper discusses the operation and control algorithms of shunt and series active filters. Performance of each of these filters is studied separately when it is connected to protect sensitive loads in a power distribution system. It is assumed that the distribution system is polluted due to ...
IEEE Transactions on Industrial Electronics, 2008
IEEE Transactions on Power Electronics, 2008
AbstractThis paper focuses on the development of multilevel hysteresis current regulation strate... more AbstractThis paper focuses on the development of multilevel hysteresis current regulation strategies. Two such strategies have been discussed and some modifications in their control tasks have been proposed to achieve more reliable and improved perfor-mance. In ...
IEEE Transactions on Power Delivery, 2003
IEEE Transactions on Power Delivery, 2007
IEEE Transactions on Power Delivery, 2000
Abstract This paper presents a new approach for generating reference currents for an active filte... more Abstract This paper presents a new approach for generating reference currents for an active filter and/or a static compensator. It is assumed that the compensator is connected to a load that may either be connected in star or in delta. The load can be unbalanced and may also ...
The paper proposes a new topology of STATCOM that is capable of supplying AC and DC loads in 3-ph... more The paper proposes a new topology of STATCOM that is capable of supplying AC and DC loads in 3-phase 4-wire distribution systems. In this, the authors utilize the method of instantaneous symmetrical components to extract the compensator reference currents that are then tracked in a hysteresis band current control mode. A suitable state space model of the STATCOM is derived. Based on this model, a single cycle control strategy is proposed and is shown to compensate for the drift in capacitor voltages due to DC components of load currents. The operation of the compensator has been verified through MATLAB simulation and detailed simulation results are given
IEEE Transactions on Power Delivery, 2004
Abstract The paper discusses the operating principles and control characteristics of a dynamic vo... more Abstract The paper discusses the operating principles and control characteristics of a dynamic voltage restorer (DVR) that protects sensitive but unbalanced and/or distorted loads. The main aim of the DVR is to regulate the voltage at the load terminal irrespective ...
IEEE Transactions on Power Delivery, 2007
IEEE Transactions on Power Delivery, 2004
AbstractThe paper discusses the concept of a mini custom power park in which the voltage inside ... more AbstractThe paper discusses the concept of a mini custom power park in which the voltage inside the park is tightly regulated by a distribution static compensator (DSTATCOM). It will be shown on the basis of simulations with ideal components that solid state protection ...