Damien Arnalsteen - Academia.edu (original) (raw)
Papers by Damien Arnalsteen
Orthopaedics & traumatology: surgery & research, May 1, 2012
When all three cup models were pooled, serum ion levels were higher in patients with pain than wi... more When all three cup models were pooled, serum ion levels were higher in patients with pain than without pain (chromium, 7.1 g/L versus 2.1 g/L [P = 0.002], and cobalt, 8 g/L versus 2.6 g/L [P = 0.0004]). Discussion: Serum chrome and cobalt levels increased after metal-on-metal total hip replacement, and the increase was greater with large-diameter implants than previously reported with 28-mm implants. Persistent pain was significantly associated with higher metal ion levels, with a probable cobalt cutoff of about 8 g/L. Differences in modular head-neck concepts may explain the observed variations.
International Orthopaedics, May 27, 2014
Purpose A full range of motion after total knee arthroplasty has become more and more requested b... more Purpose A full range of motion after total knee arthroplasty has become more and more requested by our patients, leading to novel designs of knee implants, the so-called "hyperflex" knees. The aim of the present study was to confirm whether or not hyperflexion of operated knees really improves the patients' quality of life. Methods A retrospective comparative case-control study has been carried out to compare clinical results shown in two types of knee prosthesis, from two homogeneous paired groups of patients including 45 cases of a "hyperflex" model (RP-F), while the control group consisted of 43 cases of a "regular design" model (Triathlon) in terms of expected postoperative flexion. Results The hyperflex group demonstrated significant higher mean values of passive flexion at 119.9°in the RP-F group versus 111.1°in the Triathlon group. However, global results in the "regular" control group were significantly better than the "hyperflex" study group, in both IKS knee and functional scores at 84.4 points (RP-F) vs. 89.8 points (Triathlon), and 84.6 points (RP-F) vs. 89.5 points (Triathlon), respectively. Moreover, the self-administered KOOS questionnaire was significantly in favor of the control group, with 73.5 points in RP-F knees versus 86.0 points for Triathlon knees at global KOOS postoperative scores. Conclusion The quality of life of operated patients after TKA obviously would be considered as the main priority, which was better obtained by a "regular design" in our study. Hence "high flexion" cannot be considered as an absolute target when choosing a model for total knee arthroplasty.
Revue de Chirurgie Orthopédique et Traumatologique, Nov 1, 2011
S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique R... more S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique Résultats.-Touts les TDM étaient de qualité suffisante pour la planification. Un produit dose, longueur moyenne de 304 mGy/cm (écart-type 68,2 mGy/cm) résultant en une dose efficace moyenne de 3,7 mSv (écart-type 1,0 mSv) a été déterminée. La dose efficace a été influencée par le IMC (p < 0,0001) tandis que le sexe (p = 0,08) et la présence d'une prothèse controlatérale (22 patients ; p = 0,15) se sont révélées statistiquement non significatives. L'analyse a montré les participations suivantes au processus défini de la demande du TDM au rapport écrit de la planification : radiologue quatre minutes, chirurgien 16 minutes, technicien 12 minutes, responsables de l'administration quatre minutes. Le temps d'occupation de la salle d'examen TDM était de 11 minutes. Les coûts directs étaient donc de 52,80 EUR par patient. Discussion.-La TDM s'est montrée très utile pour la planification d'une reconstruction anatomique avec des prothèses de hanche modulaires. Notre étude montre que la TDM préopératoire est associée avec une légère élévation de l'irradiation du patient comparé aux clichés en radiologie conventionnelle. Les coûts par patient sont faibles et apparaissent négligeables comparés aux coûts de la chirurgie. Conclusion.-La légère augmentation d'irradiation TDM est bien justifiable en tenant compte du résultat chirurgical avantageux.
The Journal of Hand Surgery, 2011
Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecti... more Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecting the lunate. Curettage and bone grafting of the lesion was successful, with no recurrence after 2 years of follow-up.
Orthopaedics & traumatology, surgery & research : OTSR, 2012
The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip... more The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip replacement prompted the development of large-diameter heads that more closely replicated the normal hip anatomy, with the goal of improving prosthesis stability. However, the blood release of metal ions due to wear at the bearing surfaces and the high rate of groin pain seen with large-diameter implants are causing concern. To determine whether these events are related to the geometry and metal composition of the prosthesis components, we conducted a prospective study of clinical outcomes and serum chromium and cobalt levels 1 year after implantation of three different acetabular cups. Serum levels of metal ions are comparable with different types of large-diameter metal-on-metal total hip prostheses. We compared 24 Durom™ cups (D), 23 M2a Magnum™ cups (M2a), and 20 Conserve Total™ (C) cups regarding serum chromium and cobalt levels, Postel-Merle d'Aubigné (PMA) scores and Oxford H...
Revue de Chirurgie Orthopédique et Traumatologique, 2012
Étude prospective comparative à un an de trois prothèses totales de hanche métal-métal à têtes de... more Étude prospective comparative à un an de trois prothèses totales de hanche métal-métal à têtes de gros diamètre : niveau sérique des ions métalliques et résultats cliniques ଝ One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: Serum metal ion levels and clinical outcomes
Resuscitation, 2011
Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé et de grande ta... more Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé et de grande taille interrompt la continuité osseuse et met en jeu le pronostic de la consolidation. Si un abord chirurgical permet une réduction anatomique, il augmente cependant les risques de pseudarthrose et d'infection. Nous avons donc comparé les résultats des enclouages centromédullaires opérés à foyer ouvert et fermé et analysé les complications.
International orthopaedics, 2014
A full range of motion after total knee arthroplasty has become more and more requested by our pa... more A full range of motion after total knee arthroplasty has become more and more requested by our patients, leading to novel designs of knee implants, the so-called "hyperflex" knees. The aim of the present study was to confirm whether or not hyperflexion of operated knees really improves the patients' quality of life. A retrospective comparative case-control study has been carried out to compare clinical results shown in two types of knee prosthesis, from two homogeneous paired groups of patients including 45 cases of a "hyperflex" model (RP-F), while the control group consisted of 43 cases of a "regular design" model (Triathlon) in terms of expected postoperative flexion. The hyperflex group demonstrated significant higher mean values of passive flexion at 119.9° in the RP-F group versus 111.1° in the Triathlon group. However, global results in the "regular" control group were significantly better than the "hyperflex" study group,...
Revue de Chirurgie Orthopédique et Traumatologique, 2011
S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique R... more S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique Résultats.-Touts les TDM étaient de qualité suffisante pour la planification. Un produit dose, longueur moyenne de 304 mGy/cm (écart-type 68,2 mGy/cm) résultant en une dose efficace moyenne de 3,7 mSv (écart-type 1,0 mSv) a été déterminée. La dose efficace a été influencée par le IMC (p < 0,0001) tandis que le sexe (p = 0,08) et la présence d'une prothèse controlatérale (22 patients ; p = 0,15) se sont révélées statistiquement non significatives. L'analyse a montré les participations suivantes au processus défini de la demande du TDM au rapport écrit de la planification : radiologue quatre minutes, chirurgien 16 minutes, technicien 12 minutes, responsables de l'administration quatre minutes. Le temps d'occupation de la salle d'examen TDM était de 11 minutes. Les coûts directs étaient donc de 52,80 EUR par patient.
The Journal of Hand Surgery, 2011
Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecti... more Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecting the lunate. Curettage and bone grafting of the lesion was successful, with no recurrence after 2 years of follow-up.
Clinical Anatomy, 2012
The objective of this study is to determine the relationship of the variations of the lumbar lord... more The objective of this study is to determine the relationship of the variations of the lumbar lordosis angle (LLA) to the aortic bifurcation level and inferior vena cava (IVC) confluence level using CT angiography. A retrospective study was conducted using the data available on abdominopelvic CT angiography scans. The LLA, the level and angle of bifurcation of the aorta, the level and angle of confluence of the IVC were identified using multiplanar and 3D reconstruction. Linear regression models were fitted to the data. We interpreted 181 scans for 181 individuals having a mean age of 55 years (18-89). The most common site of aortic bifurcation was at L4-L5 disc space (34.8%) and that of vena confluence was at the upper of L5 (29.3%). The mean LLA was 34.658 (138-778). The mean aortic bifurcation angle was 47.438 (178-1008) and the mean IVC confluence angle was 71.868 (308-1208). The positions of the aortic bifurcation and venous confluence levels showed a proximal shift with an increasing LLA P < 0.001. This study showed that the level of bifurcation of the aorta and the level of confluence of the IVC may vary with the variations of the LLA. Clin. Anat.
Revue de Chirurgie Orthopédique et Traumatologique, 2011
Introduction.-Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé e... more Introduction.-Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé et de grande taille interrompt la continuité osseuse et met en jeu le pronostic de la consolidation. Si un abord chirurgical permet une réduction anatomique, il augmente cependant les risques de pseudarthrose et d'infection. Nous avons donc comparé les résultats des enclouages centromédullaires opérés à foyer ouvert et fermé et analysé les complications. Patients et méthodes.-Quarante-sept malades présentant une fracture diaphysaire traumatique ouverte ou fermée, comminutive avec une écaille libre (classée B ou C de la classification AO) et ostéosynthésée par enclouage centromédullaire ont été inclus. Deux groupes ont été distingués, l'un encloué à foyer fermé (27 malades), l'autre encloué à foyer ouvert (20 malades), avec ou sans cerclage. La réduction postopératoire a été évaluée par le rapport entre le diamètre du fémur en zone comminutive et le diamètre du fémur en zone non fracturée. Cette mesure a été faite sur une radiographie de face et de profil et seul le ratio le plus élevé était retenu. Les patients ont bénéficié d'un contrôle clinique et radiologique de la consolidation.
Orthopaedics & traumatology: surgery & research, May 1, 2012
When all three cup models were pooled, serum ion levels were higher in patients with pain than wi... more When all three cup models were pooled, serum ion levels were higher in patients with pain than without pain (chromium, 7.1 g/L versus 2.1 g/L [P = 0.002], and cobalt, 8 g/L versus 2.6 g/L [P = 0.0004]). Discussion: Serum chrome and cobalt levels increased after metal-on-metal total hip replacement, and the increase was greater with large-diameter implants than previously reported with 28-mm implants. Persistent pain was significantly associated with higher metal ion levels, with a probable cobalt cutoff of about 8 g/L. Differences in modular head-neck concepts may explain the observed variations.
International Orthopaedics, May 27, 2014
Purpose A full range of motion after total knee arthroplasty has become more and more requested b... more Purpose A full range of motion after total knee arthroplasty has become more and more requested by our patients, leading to novel designs of knee implants, the so-called "hyperflex" knees. The aim of the present study was to confirm whether or not hyperflexion of operated knees really improves the patients' quality of life. Methods A retrospective comparative case-control study has been carried out to compare clinical results shown in two types of knee prosthesis, from two homogeneous paired groups of patients including 45 cases of a "hyperflex" model (RP-F), while the control group consisted of 43 cases of a "regular design" model (Triathlon) in terms of expected postoperative flexion. Results The hyperflex group demonstrated significant higher mean values of passive flexion at 119.9°in the RP-F group versus 111.1°in the Triathlon group. However, global results in the "regular" control group were significantly better than the "hyperflex" study group, in both IKS knee and functional scores at 84.4 points (RP-F) vs. 89.8 points (Triathlon), and 84.6 points (RP-F) vs. 89.5 points (Triathlon), respectively. Moreover, the self-administered KOOS questionnaire was significantly in favor of the control group, with 73.5 points in RP-F knees versus 86.0 points for Triathlon knees at global KOOS postoperative scores. Conclusion The quality of life of operated patients after TKA obviously would be considered as the main priority, which was better obtained by a "regular design" in our study. Hence "high flexion" cannot be considered as an absolute target when choosing a model for total knee arthroplasty.
Revue de Chirurgie Orthopédique et Traumatologique, Nov 1, 2011
S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique R... more S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique Résultats.-Touts les TDM étaient de qualité suffisante pour la planification. Un produit dose, longueur moyenne de 304 mGy/cm (écart-type 68,2 mGy/cm) résultant en une dose efficace moyenne de 3,7 mSv (écart-type 1,0 mSv) a été déterminée. La dose efficace a été influencée par le IMC (p < 0,0001) tandis que le sexe (p = 0,08) et la présence d'une prothèse controlatérale (22 patients ; p = 0,15) se sont révélées statistiquement non significatives. L'analyse a montré les participations suivantes au processus défini de la demande du TDM au rapport écrit de la planification : radiologue quatre minutes, chirurgien 16 minutes, technicien 12 minutes, responsables de l'administration quatre minutes. Le temps d'occupation de la salle d'examen TDM était de 11 minutes. Les coûts directs étaient donc de 52,80 EUR par patient. Discussion.-La TDM s'est montrée très utile pour la planification d'une reconstruction anatomique avec des prothèses de hanche modulaires. Notre étude montre que la TDM préopératoire est associée avec une légère élévation de l'irradiation du patient comparé aux clichés en radiologie conventionnelle. Les coûts par patient sont faibles et apparaissent négligeables comparés aux coûts de la chirurgie. Conclusion.-La légère augmentation d'irradiation TDM est bien justifiable en tenant compte du résultat chirurgical avantageux.
The Journal of Hand Surgery, 2011
Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecti... more Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecting the lunate. Curettage and bone grafting of the lesion was successful, with no recurrence after 2 years of follow-up.
Orthopaedics & traumatology, surgery & research : OTSR, 2012
The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip... more The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip replacement prompted the development of large-diameter heads that more closely replicated the normal hip anatomy, with the goal of improving prosthesis stability. However, the blood release of metal ions due to wear at the bearing surfaces and the high rate of groin pain seen with large-diameter implants are causing concern. To determine whether these events are related to the geometry and metal composition of the prosthesis components, we conducted a prospective study of clinical outcomes and serum chromium and cobalt levels 1 year after implantation of three different acetabular cups. Serum levels of metal ions are comparable with different types of large-diameter metal-on-metal total hip prostheses. We compared 24 Durom™ cups (D), 23 M2a Magnum™ cups (M2a), and 20 Conserve Total™ (C) cups regarding serum chromium and cobalt levels, Postel-Merle d'Aubigné (PMA) scores and Oxford H...
Revue de Chirurgie Orthopédique et Traumatologique, 2012
Étude prospective comparative à un an de trois prothèses totales de hanche métal-métal à têtes de... more Étude prospective comparative à un an de trois prothèses totales de hanche métal-métal à têtes de gros diamètre : niveau sérique des ions métalliques et résultats cliniques ଝ One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: Serum metal ion levels and clinical outcomes
Resuscitation, 2011
Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé et de grande ta... more Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé et de grande taille interrompt la continuité osseuse et met en jeu le pronostic de la consolidation. Si un abord chirurgical permet une réduction anatomique, il augmente cependant les risques de pseudarthrose et d'infection. Nous avons donc comparé les résultats des enclouages centromédullaires opérés à foyer ouvert et fermé et analysé les complications.
International orthopaedics, 2014
A full range of motion after total knee arthroplasty has become more and more requested by our pa... more A full range of motion after total knee arthroplasty has become more and more requested by our patients, leading to novel designs of knee implants, the so-called "hyperflex" knees. The aim of the present study was to confirm whether or not hyperflexion of operated knees really improves the patients' quality of life. A retrospective comparative case-control study has been carried out to compare clinical results shown in two types of knee prosthesis, from two homogeneous paired groups of patients including 45 cases of a "hyperflex" model (RP-F), while the control group consisted of 43 cases of a "regular design" model (Triathlon) in terms of expected postoperative flexion. The hyperflex group demonstrated significant higher mean values of passive flexion at 119.9° in the RP-F group versus 111.1° in the Triathlon group. However, global results in the "regular" control group were significantly better than the "hyperflex" study group,...
Revue de Chirurgie Orthopédique et Traumatologique, 2011
S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique R... more S332 86 e réunion annuelle de la Société française de chirurgie orthopédique et traumatologique Résultats.-Touts les TDM étaient de qualité suffisante pour la planification. Un produit dose, longueur moyenne de 304 mGy/cm (écart-type 68,2 mGy/cm) résultant en une dose efficace moyenne de 3,7 mSv (écart-type 1,0 mSv) a été déterminée. La dose efficace a été influencée par le IMC (p < 0,0001) tandis que le sexe (p = 0,08) et la présence d'une prothèse controlatérale (22 patients ; p = 0,15) se sont révélées statistiquement non significatives. L'analyse a montré les participations suivantes au processus défini de la demande du TDM au rapport écrit de la planification : radiologue quatre minutes, chirurgien 16 minutes, technicien 12 minutes, responsables de l'administration quatre minutes. Le temps d'occupation de la salle d'examen TDM était de 11 minutes. Les coûts directs étaient donc de 52,80 EUR par patient.
The Journal of Hand Surgery, 2011
Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecti... more Aneurysmal bone cysts rarely affect the carpus. We present a case of aneurysmal bone cyst affecting the lunate. Curettage and bone grafting of the lesion was successful, with no recurrence after 2 years of follow-up.
Clinical Anatomy, 2012
The objective of this study is to determine the relationship of the variations of the lumbar lord... more The objective of this study is to determine the relationship of the variations of the lumbar lordosis angle (LLA) to the aortic bifurcation level and inferior vena cava (IVC) confluence level using CT angiography. A retrospective study was conducted using the data available on abdominopelvic CT angiography scans. The LLA, the level and angle of bifurcation of the aorta, the level and angle of confluence of the IVC were identified using multiplanar and 3D reconstruction. Linear regression models were fitted to the data. We interpreted 181 scans for 181 individuals having a mean age of 55 years (18-89). The most common site of aortic bifurcation was at L4-L5 disc space (34.8%) and that of vena confluence was at the upper of L5 (29.3%). The mean LLA was 34.658 (138-778). The mean aortic bifurcation angle was 47.438 (178-1008) and the mean IVC confluence angle was 71.868 (308-1208). The positions of the aortic bifurcation and venous confluence levels showed a proximal shift with an increasing LLA P < 0.001. This study showed that the level of bifurcation of the aorta and the level of confluence of the IVC may vary with the variations of the LLA. Clin. Anat.
Revue de Chirurgie Orthopédique et Traumatologique, 2011
Introduction.-Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé e... more Introduction.-Dans les fractures diaphysaires comminutives du fémur, un fragment libre, déplacé et de grande taille interrompt la continuité osseuse et met en jeu le pronostic de la consolidation. Si un abord chirurgical permet une réduction anatomique, il augmente cependant les risques de pseudarthrose et d'infection. Nous avons donc comparé les résultats des enclouages centromédullaires opérés à foyer ouvert et fermé et analysé les complications. Patients et méthodes.-Quarante-sept malades présentant une fracture diaphysaire traumatique ouverte ou fermée, comminutive avec une écaille libre (classée B ou C de la classification AO) et ostéosynthésée par enclouage centromédullaire ont été inclus. Deux groupes ont été distingués, l'un encloué à foyer fermé (27 malades), l'autre encloué à foyer ouvert (20 malades), avec ou sans cerclage. La réduction postopératoire a été évaluée par le rapport entre le diamètre du fémur en zone comminutive et le diamètre du fémur en zone non fracturée. Cette mesure a été faite sur une radiographie de face et de profil et seul le ratio le plus élevé était retenu. Les patients ont bénéficié d'un contrôle clinique et radiologique de la consolidation.