Research paper thumbnail of Impact of the introduction of 16-row MDCT on image quality and patient dose: phantom study and multi-centre survey

European Radiology, 2006

The purpose was to compare the image quality and patient dose between 4- and 16-row MDCT units an... more The purpose was to compare the image quality and patient dose between 4- and 16-row MDCT units and to evaluate the dispersion of the dose delivered for common clinical examinations. Four 4- and 16-row MDCT units were used in the study. Image noise levels from images of a CatPhan phantom were compared for all units using a given CTDIvol of 15.0±1.0 mGy. Standard acquisition protocols from ten centres, shifted from 4- to 16-row MDCT (plus one additional centre for 16-row MDCT), were compared for cerebral angiography and standard chest and abdomen examinations. In addition, the protocols used with 16-row MDCT units for diagnosis of the unstable shoulder and for cardiac examinations were also compared. The introduction of 16-MSCT units did not reduce the performance of the detectors. Concerning the acquisition protocols, a wide range in practice was observed for standard examinations; DLP varied from 800 to 5,120 mGy.cm, 130 to 860 mGy.cm, 410 to 1,790 mGy.cm and 850 to 2,500 mGy.cm for cerebral angiography, standard chest, standard abdomen and heart examinations, respectively.The introduction of 16-row MDCT did not, on average, increase the patient dose for standard chest and abdominal examinations. However, a significant dose increase has been observed for cerebral angiography. There is a wide dispersion in the doses delivered, especially for cardiac imaging.

Research paper thumbnail of CT Dose Optimization When Changing to CT Multi-Detector Row Technology

Current Problems in Diagnostic Radiology, 2007

The purpose of this article was to review the strategies to control patient dose in adult and ped... more The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Research paper thumbnail of CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland

European Radiology, 2008

This work aimed at assessing the doses delivered in Switzerland to paediatric patients during com... more This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDIvol) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDIvol: 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.

Research paper thumbnail of JIMENA

Research paper thumbnail of Impact of the introduction of 16-row MDCT on image quality and patient dose: phantom study and multi-centre survey

European Radiology, 2006

The purpose was to compare the image quality and patient dose between 4- and 16-row MDCT units an... more The purpose was to compare the image quality and patient dose between 4- and 16-row MDCT units and to evaluate the dispersion of the dose delivered for common clinical examinations. Four 4- and 16-row MDCT units were used in the study. Image noise levels from images of a CatPhan phantom were compared for all units using a given CTDIvol of 15.0±1.0 mGy. Standard acquisition protocols from ten centres, shifted from 4- to 16-row MDCT (plus one additional centre for 16-row MDCT), were compared for cerebral angiography and standard chest and abdomen examinations. In addition, the protocols used with 16-row MDCT units for diagnosis of the unstable shoulder and for cardiac examinations were also compared. The introduction of 16-MSCT units did not reduce the performance of the detectors. Concerning the acquisition protocols, a wide range in practice was observed for standard examinations; DLP varied from 800 to 5,120 mGy.cm, 130 to 860 mGy.cm, 410 to 1,790 mGy.cm and 850 to 2,500 mGy.cm for cerebral angiography, standard chest, standard abdomen and heart examinations, respectively.The introduction of 16-row MDCT did not, on average, increase the patient dose for standard chest and abdominal examinations. However, a significant dose increase has been observed for cerebral angiography. There is a wide dispersion in the doses delivered, especially for cardiac imaging.

Research paper thumbnail of CT Dose Optimization When Changing to CT Multi-Detector Row Technology

Current Problems in Diagnostic Radiology, 2007

The purpose of this article was to review the strategies to control patient dose in adult and ped... more The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Research paper thumbnail of CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland

European Radiology, 2008

This work aimed at assessing the doses delivered in Switzerland to paediatric patients during com... more This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDIvol) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDIvol: 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.

Research paper thumbnail of JIMENA