Divya Saxena - Academia.edu (original) (raw)

Papers by Divya Saxena

Research paper thumbnail of {"__content__"=>"A comparative evaluation of accuracy of three electronic apex locators using histological section as gold standard: An study.", "i"=>{"__content__"=>"ex vivo"}}

Journal of conservative dentistry : JCD

The aim of the present study was to comparatively evaluate the accuracy of iRoot, iPex II, and Pr... more The aim of the present study was to comparatively evaluate the accuracy of iRoot, iPex II, and Propex pixi apex locator using histological sections as the gold standard. Thirty patients indicated for extraction of single-rooted permanent teeth with single canal system were selected. Working lengths (WLs) of teeth were determined using iRoot, iPex II, and Propex pixi. Teeth were then extracted, and the files were reintroduced to the anatomic apex to measure anatomic canal length (ACL) and fixed at the ACL using flowable composite. The apical 4 mm of the roots were longitudinally shaved away to visualize the canal under a stereomicroscope at ×24 magnification. Digital photographs were evaluated to measure the distance between the major diameter and minor diameter. Thus, the WL, that is, the minor diameter length (MDL) was ascertained. Measurements of mean WLs within ±0.5 mm of minor diameter were 90% acceptable for iRoot, 86.66% for iPex II, and 80% for Propex pixi when compared with ...

Research paper thumbnail of Perception of Acceptable Range of Smiles by Specialists, General Dentists and Lay Persons and Evaluation of Different Aesthetic Paradigms

Journal of clinical and diagnostic research : JCDR, 2017

One of the most important goals of restorative dentistry is to restore the patient's aestheti... more One of the most important goals of restorative dentistry is to restore the patient's aesthetic. Smile analysis is subjective and it differs from person to person. An aesthetic smile involves a harmonious relationship between various parameters including the hard and soft tissues. The aim of the study was to identify the acceptable range of several smiles (alone and in conjunction with the face) by specialists, general dentists as well as lay persons; and to identify the values of different criteria i.e., the Golden Proportion (GP), the Recurrent Esthetic Dental proportion (RED), Width to Height ratio (W/H ratio), the Apparent Contact Dimension (ACD), and lateral incisor position in a smile. Hundred photographs of 50 subjects were taken, 50 of the smile alone and 50 of the individual's frontal view of face. The photographs of the smiles and the faces were assessed for the aesthetic acceptability by 30 evaluators including 10 specialists with advanced training, 10 general dent...

Research paper thumbnail of Retracted: Evaluation of the incidence of microcracks caused by Mtwo and ProTaper NEXT rotary file systems versus the Self Adjusting File: a scanning electron microscopic study

International Endodontic Journal, 2016

The following article from International Endodontic Journal, ‘Evaluation of the incidence of micr... more The following article from International Endodontic Journal, ‘Evaluation of the incidence of microcracks caused by Mtwo and ProTaper NEXT rotary file systems versus the Self Adjusting File: a scanning electron microscopic study’ by S. G. Saha, N. Vijaywargiya, S. Dubey, D. Saxena & S. Kala, published online on 24 November 2015 in Wiley Online Library (wileyonlinelibrary.com), has been retracted by agreement between the authors, the journal Editor in Chief, Prof. Paul Dummer, and John Wiley & Sons Ltd. The retraction has been agreed due to the consideration that the SEM methodology used by the authors has the potential to cause cracks and is thus is not suitable for the evaluation of micro‐cracks in roots.

Research paper thumbnail of In vitro evaluation of the antimicrobial activity of lichen metabolites as potential preservatives

Antimicrobial Agents and Chemotherapy, 1985

Antimicrobial screening of several lichen species and subsequent isolation and structure elucidat... more Antimicrobial screening of several lichen species and subsequent isolation and structure elucidation of active compounds revealed that the hydrolysis products of certain lichen metabolites, i.e., depsides, were active against gram-negative bacteria and fungi as well as gram-positive bacteria. The active constituents isolated from Stereocaulon alpinum and Peltigera aphthosa were identified, respectively, as methyl beta-orsellinate and a mixture of methyl and ethyl orsellinates. MIC determinations indicated that activity of these compounds was superior to that of the commonly used preservative agents methyl and propyl p-hydroxybenzoates and was of the same order as that of chlorocresol.

Research paper thumbnail of {"__content__"=>"A comparative evaluation of accuracy of three electronic apex locators using histological section as gold standard: An study.", "i"=>{"__content__"=>"ex vivo"}}

Journal of conservative dentistry : JCD

The aim of the present study was to comparatively evaluate the accuracy of iRoot, iPex II, and Pr... more The aim of the present study was to comparatively evaluate the accuracy of iRoot, iPex II, and Propex pixi apex locator using histological sections as the gold standard. Thirty patients indicated for extraction of single-rooted permanent teeth with single canal system were selected. Working lengths (WLs) of teeth were determined using iRoot, iPex II, and Propex pixi. Teeth were then extracted, and the files were reintroduced to the anatomic apex to measure anatomic canal length (ACL) and fixed at the ACL using flowable composite. The apical 4 mm of the roots were longitudinally shaved away to visualize the canal under a stereomicroscope at ×24 magnification. Digital photographs were evaluated to measure the distance between the major diameter and minor diameter. Thus, the WL, that is, the minor diameter length (MDL) was ascertained. Measurements of mean WLs within ±0.5 mm of minor diameter were 90% acceptable for iRoot, 86.66% for iPex II, and 80% for Propex pixi when compared with ...

Research paper thumbnail of Perception of Acceptable Range of Smiles by Specialists, General Dentists and Lay Persons and Evaluation of Different Aesthetic Paradigms

Journal of clinical and diagnostic research : JCDR, 2017

One of the most important goals of restorative dentistry is to restore the patient's aestheti... more One of the most important goals of restorative dentistry is to restore the patient's aesthetic. Smile analysis is subjective and it differs from person to person. An aesthetic smile involves a harmonious relationship between various parameters including the hard and soft tissues. The aim of the study was to identify the acceptable range of several smiles (alone and in conjunction with the face) by specialists, general dentists as well as lay persons; and to identify the values of different criteria i.e., the Golden Proportion (GP), the Recurrent Esthetic Dental proportion (RED), Width to Height ratio (W/H ratio), the Apparent Contact Dimension (ACD), and lateral incisor position in a smile. Hundred photographs of 50 subjects were taken, 50 of the smile alone and 50 of the individual's frontal view of face. The photographs of the smiles and the faces were assessed for the aesthetic acceptability by 30 evaluators including 10 specialists with advanced training, 10 general dent...

Research paper thumbnail of Retracted: Evaluation of the incidence of microcracks caused by Mtwo and ProTaper NEXT rotary file systems versus the Self Adjusting File: a scanning electron microscopic study

International Endodontic Journal, 2016

The following article from International Endodontic Journal, ‘Evaluation of the incidence of micr... more The following article from International Endodontic Journal, ‘Evaluation of the incidence of microcracks caused by Mtwo and ProTaper NEXT rotary file systems versus the Self Adjusting File: a scanning electron microscopic study’ by S. G. Saha, N. Vijaywargiya, S. Dubey, D. Saxena & S. Kala, published online on 24 November 2015 in Wiley Online Library (wileyonlinelibrary.com), has been retracted by agreement between the authors, the journal Editor in Chief, Prof. Paul Dummer, and John Wiley & Sons Ltd. The retraction has been agreed due to the consideration that the SEM methodology used by the authors has the potential to cause cracks and is thus is not suitable for the evaluation of micro‐cracks in roots.

Research paper thumbnail of In vitro evaluation of the antimicrobial activity of lichen metabolites as potential preservatives

Antimicrobial Agents and Chemotherapy, 1985

Antimicrobial screening of several lichen species and subsequent isolation and structure elucidat... more Antimicrobial screening of several lichen species and subsequent isolation and structure elucidation of active compounds revealed that the hydrolysis products of certain lichen metabolites, i.e., depsides, were active against gram-negative bacteria and fungi as well as gram-positive bacteria. The active constituents isolated from Stereocaulon alpinum and Peltigera aphthosa were identified, respectively, as methyl beta-orsellinate and a mixture of methyl and ethyl orsellinates. MIC determinations indicated that activity of these compounds was superior to that of the commonly used preservative agents methyl and propyl p-hydroxybenzoates and was of the same order as that of chlorocresol.