Dr Manish Deshmukh - Academia.edu (original) (raw)
Papers by Dr Manish Deshmukh
Journal of Biomimetics, Biomaterials and Biomedical Engineering
The hip is one in every of the various joint at intervals the body. The correct operating of this... more The hip is one in every of the various joint at intervals the body. The correct operating of this joint is essential. For the aim once the hip is injured whole, a substitution procedure of the entire joint ought to be done to reinstate its operating, that is known as absolute hip surgical process. It is finished with the assistance of inserts of various biomaterials, as an example, polymers, metals, and pottery. The primary issues with regard to the utilization of various biomaterials are the reaction of the body's instrument to wear trash. Throughout this audit, biomaterials that are developing is talked regarding aboard the wear and tear and tear conduct and instrument. To boot, the numerous properties of the biomaterials are talked regarding aboard the expected preferences and drawbacks of their utilization. Further, the blends of various biomaterials at intervals the articulating surfaces are cleft and so the problems regarding their utilization are assessed. This paper hope...
Thermal Science, 2021
The current work investigates experimental characteristics of the Photovoltaic Thermal system int... more The current work investigates experimental characteristics of the Photovoltaic Thermal system integrated with CuO-Water spiral flow heat exchanger and compared with non-cooled PV module. The work describes detailed procedure of Nanoparticles (NPs) preparation, SEM characterizations and heat extraction characteristics of Nanofluid (NFs) in PVT application. The heat exchanger was pasted at the back of polycrystalline PV module to form PVT system to examine cooling ability, power generation, thermal-electrical yield and overall efficiency at a different volume concentration of CuO NPs at steady mass flow rate of 0.08 kg/sec. From the experiments, it was concluded that the CuO-Water NFs assisted to lessen surface temperature of PV module by extracting heat that enhanced electrical efficiency by an average of 3.53%. It was also seen that electrical and thermal performance was improved at higher volume concentration and overall efficiency of 30.77% and 36.59 % were obtained at 0.01% and 0...
ARTICLE INFO The continuous increase in the cost and demand for energy has led to more research a... more ARTICLE INFO The continuous increase in the cost and demand for energy has led to more research and development to utilize available energy resources efficiently. Vapour compression refrigeration method is an efficient method of refrigeration among the different methods, but the energy inputs to the Vapour compression system is high grade energy. This study focuses on an experimental study of hydrocarbon blend of isobutane (R600a) and propane (R-290) as an environment friendly refrigerators with zero ozone depletion potential (ODP) and very low global warming potential (GWP), to replace conventional refrigerators tetrafluoroethane R-134a in a domestic refrigerators. The performance is observed for a domestic refrigerator by using blend of hydrocarbon R600a and R-290 and its performance is compared with R-134a without change in original system. Due to the higher value of latent heat of hydrocarbons the amount of refrigerant charge required found to be reduced as compared with hydrofl...
Biointerface Research in Applied Chemistry, 2021
Biomechanics is the interdisciplinary area comprising biomedical and mechanical domain, continuat... more Biomechanics is the interdisciplinary area comprising biomedical and mechanical domain, continuations in research of alternative and sustainable materials, which refers to the mechanical examine. This current work focuses on hip implant material development through analytical and finite element analysis. The femur bone head is 3D modeled through computed tomography (CT) images extracted data and modeled in SOLIDWORKS. The analytical analysis is performed on the femur head through Hertzian theory. The finite element analysis (FEA) (static structural analysis) is carried out in the ANSYS 19.2. The materials considered for the FEA are NbTiZrMo alloy, PEEK and CFR-PEEK for the hip implant. The analytical analysis is performed for eight different human routine activities, and the highest peak stress value is obtained for walking fast. The peak stress values obtained in FEA for CFR-PEEK material implant are lower than the maximum peak stress obtained by analytical analysis. The stress val...
Journal of Biomimetics, Biomaterials and Biomedical Engineering
The hip is one in every of the various joint at intervals the body. The correct operating of this... more The hip is one in every of the various joint at intervals the body. The correct operating of this joint is essential. For the aim once the hip is injured whole, a substitution procedure of the entire joint ought to be done to reinstate its operating, that is known as absolute hip surgical process. It is finished with the assistance of inserts of various biomaterials, as an example, polymers, metals, and pottery. The primary issues with regard to the utilization of various biomaterials are the reaction of the body's instrument to wear trash. Throughout this audit, biomaterials that are developing is talked regarding aboard the wear and tear and tear conduct and instrument. To boot, the numerous properties of the biomaterials are talked regarding aboard the expected preferences and drawbacks of their utilization. Further, the blends of various biomaterials at intervals the articulating surfaces are cleft and so the problems regarding their utilization are assessed. This paper hope...
Thermal Science, 2021
The current work investigates experimental characteristics of the Photovoltaic Thermal system int... more The current work investigates experimental characteristics of the Photovoltaic Thermal system integrated with CuO-Water spiral flow heat exchanger and compared with non-cooled PV module. The work describes detailed procedure of Nanoparticles (NPs) preparation, SEM characterizations and heat extraction characteristics of Nanofluid (NFs) in PVT application. The heat exchanger was pasted at the back of polycrystalline PV module to form PVT system to examine cooling ability, power generation, thermal-electrical yield and overall efficiency at a different volume concentration of CuO NPs at steady mass flow rate of 0.08 kg/sec. From the experiments, it was concluded that the CuO-Water NFs assisted to lessen surface temperature of PV module by extracting heat that enhanced electrical efficiency by an average of 3.53%. It was also seen that electrical and thermal performance was improved at higher volume concentration and overall efficiency of 30.77% and 36.59 % were obtained at 0.01% and 0...
ARTICLE INFO The continuous increase in the cost and demand for energy has led to more research a... more ARTICLE INFO The continuous increase in the cost and demand for energy has led to more research and development to utilize available energy resources efficiently. Vapour compression refrigeration method is an efficient method of refrigeration among the different methods, but the energy inputs to the Vapour compression system is high grade energy. This study focuses on an experimental study of hydrocarbon blend of isobutane (R600a) and propane (R-290) as an environment friendly refrigerators with zero ozone depletion potential (ODP) and very low global warming potential (GWP), to replace conventional refrigerators tetrafluoroethane R-134a in a domestic refrigerators. The performance is observed for a domestic refrigerator by using blend of hydrocarbon R600a and R-290 and its performance is compared with R-134a without change in original system. Due to the higher value of latent heat of hydrocarbons the amount of refrigerant charge required found to be reduced as compared with hydrofl...
Biointerface Research in Applied Chemistry, 2021
Biomechanics is the interdisciplinary area comprising biomedical and mechanical domain, continuat... more Biomechanics is the interdisciplinary area comprising biomedical and mechanical domain, continuations in research of alternative and sustainable materials, which refers to the mechanical examine. This current work focuses on hip implant material development through analytical and finite element analysis. The femur bone head is 3D modeled through computed tomography (CT) images extracted data and modeled in SOLIDWORKS. The analytical analysis is performed on the femur head through Hertzian theory. The finite element analysis (FEA) (static structural analysis) is carried out in the ANSYS 19.2. The materials considered for the FEA are NbTiZrMo alloy, PEEK and CFR-PEEK for the hip implant. The analytical analysis is performed for eight different human routine activities, and the highest peak stress value is obtained for walking fast. The peak stress values obtained in FEA for CFR-PEEK material implant are lower than the maximum peak stress obtained by analytical analysis. The stress val...