Georges Obeid - Academia.edu (original) (raw)
Papers by Georges Obeid
European Journal of Applied Physiology, 2018
Purpose A reduction in ambient pressure or decompression from scuba diving can result in ultrasou... more Purpose A reduction in ambient pressure or decompression from scuba diving can result in ultrasound-detectable venous gas emboli (VGE). These environmental exposures carry a risk of decompression sickness (DCS) which is mitigated by adherence to decompression schedules; however, bubbles are routinely observed for dives well within these limits and significant inter-personal variability in DCS risk exists. Here, we assess the variability and evolution of VGE for 2 h post-dive using echocardiography, following a standardized pool dive in calm warm conditions. Methods 14 divers performed either one or two (with a 24 h interval) standardized scuba dives to 33 mfw (400 kPa) for 20 min of immersion time at NEMO 33 in Brussels, Belgium. Measurements were performed at 21, 56, 91 and 126 min post-dive: bubbles were counted for all 68 echocardiography recordings and the average over ten consecutive cardiac cycles taken as the bubble score. Results Significant inter-personal variability was demonstrated despite all divers following the same protocol in controlled pool conditions: in the detection or not of VGE, in the peak VGE score, as well as time to VGE peak. In addition, intrapersonal differences in 2/3 of the consecutive day dives were seen (lower VGE counts or faster clearance). Conclusions Since VGE evolution post-dive varies between people, more work is clearly needed to isolate contributing factors. In this respect, going toward a more continuous evaluation, or developing new means to detect decompression stress markers, may offer the ability to better assess dynamic correlations to other physiological parameters.
International Journal of Environmental Research and Public Health
Background: This study aimed to observe the effects of a fast acute ascent to simulated high alti... more Background: This study aimed to observe the effects of a fast acute ascent to simulated high altitudes on cardiovascular function both in the main arteries and in peripheral circulation. Methods: We examined 17 healthy volunteers, between 18 and 50 years old, at sea level, at 3842 m of hypobaric hypoxia and after return to sea level. Cardiac output (CO) was measured with Doppler transthoracic echocardiography. Oxygen delivery was estimated as the product of CO and peripheral oxygen saturation (SpO2). The brachial artery’s flow-mediated dilation (FMD) was measured with the ultrasound method. Post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography. Results: During altitude stay, peripheral oxygen saturation decreased (84.9 ± 4.2% of pre-ascent values; p < 0.001). None of the volunteers presented any hypoxia-related symptoms. Nevertheless, an increase in cardiac output (143.2 ± 36.2% of pre-ascent values, p < 0.001) and oxygen delivery index (120.6 ± 28.4...
Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc, 2013
OBJECTIVE Scuba and breath-hold divers are compared to investigate whether endothelial response c... more OBJECTIVE Scuba and breath-hold divers are compared to investigate whether endothelial response changes are similar despite different exposure(s) to hyperoxia. DESIGN 14 divers (nine scuba and five breath-holding) performed either one scuba dive (25m/25 minutes) or successive breath-hold dives at a depth of 20 meters, adding up to 25 minutes of immersion time in a diving pool. Flow-mediated dilation (FMD) was measured using echography. Peripheral post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography and plasmatic nitric oxide (NO) concentration using a nitrate/nitrite colorimetric assay kit. RESULTS The FMD decreased in both groups. PORH was reduced in scuba divers but increased in breath-hold divers. No difference in circulating NO was observed for the scuba group. Opposingly, an increase in circulating NO was observed for the breath-hold group. CONCLUSION Some cardiovascular effects can be explained by interaction between NO and superoxide anion during b...
Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc
Scuba and breath-hold divers are compared to investigate whether endothelial response changes are... more Scuba and breath-hold divers are compared to investigate whether endothelial response changes are similar despite different exposure(s) to hyperoxia. 14 divers (nine scuba and five breath-holding) performed either one scuba dive (25m/25 minutes) or successive breath-hold dives at a depth of 20 meters, adding up to 25 minutes of immersion time in a diving pool. Flow-mediated dilation (FMD) was measured using echography. Peripheral post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography and plasmatic nitric oxide (NO) concentration using a nitrate/nitrite colorimetric assay kit. The FMD decreased in both groups. PORH was reduced in scuba divers but increased in breath-hold divers. No difference in circulating NO was observed for the scuba group. Opposingly, an increase in circulating NO was observed for the breath-hold group. Some cardiovascular effects can be explained by interaction between NO and superoxide anion during both types of diving ending to less N...
Objective: Scuba and breath-hold divers are compared to investigate whether endothelial response ... more Objective: Scuba and breath-hold divers are compared to investigate whether endothelial response changes are similar despite different exposure(s) to hyperoxia. Design: 14 divers (nine scuba and five breath-holding) performed either one scuba dive (25m/25 minutes) or successive breath-hold dives at a depth of 20 meters, adding up to 25 minutes of immersion time in a diving pool. Flow-mediated dilation (FMD) was measured using echography. Peripheral post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography and plasmatic nitric oxide (NO) concentration using a nitrate/nitrite colorimetric assay kit. Results: The FMD decreased in both groups. PORH was reduced in scuba divers but increased in breathhold divers. No difference in circulating NO was observed for the scuba group. Opposingly, an increase in circulating NO was observed for the breath-hold group. Conclusion: Some cardiovascular effects can be explained by interaction between NO and superoxide anion during both types of diving ending to less NO availability and reducing FMD. The increased circulating NO in the breath-hold group can be caused by physical exercise. The opposite effects found between FMD and PORH in the breath-hold group can be assimilated to a greater responsiveness to circulating NO in small arteries than in large arteries. _____________________________________________________________________________________________
Diving and hyperbaric medicine, 2014
INTRODUCTION 'Decompression stress' is commonly evaluated by scoring circulating bubble n... more INTRODUCTION 'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profiles. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. METHODS Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were...
Diving and hyperbaric medicine, 2014
Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. ... more Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. The use of portable 2D echocardiography and 'frame-based' bubble counting as a tool to evaluate diving decompression stress. Diving and Hyperbaric Medicine. 2014 March;44(1):5-13.) Introduction: 'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profi les. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. Methods: Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were randomly repeated. A Wilcoxon Spearman rho calculation was used to assess test-retest reliability of each rater for the repeated still frames. For the video images, weighted kappa statistics, with linear and quadratic weightings, were calculated to measure agreement between raters for the Eftedal and Brubakk method. Bland-Altman plots and intra-class correlation coeffi cients were used to measure agreement between raters for the frame-based counting method. Results: Frame-based counting showed a better inter-rater agreement than the Eftedal and Brubakk grading, even with relatively inexperienced assessors, and has good intra-and inter-rater reliability. Conclusion: Frame-based bubble counting could be used to evaluate post-dive decompression stress, and offers possibilities for computer-automated algorithms to allow near-real-time counting.
Medical hypotheses, Jan 28, 2015
&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;... more &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot;Cutis Marmorata&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot; skin symptoms after diving, most frequently in the form of an itching or painful cutaneous red-bluish discoloration are commonly regarded as a mild form of decompression sickness (DCS), and treated with oxygen inhalation without reverting to hyperbaric recompression treatment. It has been observed that the occurrence of Cutis Marmorata is frequently associated with the presence of a Patent Foramen Ovale (PFO) of the heart, and indeed, with a properly executed contrast echocardiographic technique, these patients have an almost 100% prevalence of PFO. Only occasionally, Cutis Marmorata is accompanied by other symptoms of DCS. These symptoms usually are in the form of visual distortions, vertigo, or mild, vague but generalized cerebral dysfunction (such as abnormal fatigue, clumsiness, concentration problems). The pathogenesis of these other manifestations is clearly emboligenic, and we hypothesize that Cutis Marmorata is also a manifestation of gas bubbles embolizing the brain stem: the site of autonomic nervous system regulation of skin blood vessel dilation and constriction. The consequences of this hypothesis are that Cutis Marmorata skin decompression sickness should no longer be considered a mild, innocuous form but rather a serious, neurological form and treated accordingly.
Diving and hyperbaric medicine, 2014
Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. ... more Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. The use of portable 2D echocardiography and 'frame-based' bubble counting as a tool to evaluate diving decompression stress. Diving and Hyperbaric Medicine. 2014 March;44(1):5-13.) Introduction: 'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profi les. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. Methods: Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were randomly repeated. A Wilcoxon Spearman rho calculation was used to assess test-retest reliability of each rater for the repeated still frames. For the video images, weighted kappa statistics, with linear and quadratic weightings, were calculated to measure agreement between raters for the Eftedal and Brubakk method. Bland-Altman plots and intra-class correlation coeffi cients were used to measure agreement between raters for the frame-based counting method. Results: Frame-based counting showed a better inter-rater agreement than the Eftedal and Brubakk grading, even with relatively inexperienced assessors, and has good intra-and inter-rater reliability. Conclusion: Frame-based bubble counting could be used to evaluate post-dive decompression stress, and offers possibilities for computer-automated algorithms to allow near-real-time counting.
European Journal of Applied Physiology, 2018
Purpose A reduction in ambient pressure or decompression from scuba diving can result in ultrasou... more Purpose A reduction in ambient pressure or decompression from scuba diving can result in ultrasound-detectable venous gas emboli (VGE). These environmental exposures carry a risk of decompression sickness (DCS) which is mitigated by adherence to decompression schedules; however, bubbles are routinely observed for dives well within these limits and significant inter-personal variability in DCS risk exists. Here, we assess the variability and evolution of VGE for 2 h post-dive using echocardiography, following a standardized pool dive in calm warm conditions. Methods 14 divers performed either one or two (with a 24 h interval) standardized scuba dives to 33 mfw (400 kPa) for 20 min of immersion time at NEMO 33 in Brussels, Belgium. Measurements were performed at 21, 56, 91 and 126 min post-dive: bubbles were counted for all 68 echocardiography recordings and the average over ten consecutive cardiac cycles taken as the bubble score. Results Significant inter-personal variability was demonstrated despite all divers following the same protocol in controlled pool conditions: in the detection or not of VGE, in the peak VGE score, as well as time to VGE peak. In addition, intrapersonal differences in 2/3 of the consecutive day dives were seen (lower VGE counts or faster clearance). Conclusions Since VGE evolution post-dive varies between people, more work is clearly needed to isolate contributing factors. In this respect, going toward a more continuous evaluation, or developing new means to detect decompression stress markers, may offer the ability to better assess dynamic correlations to other physiological parameters.
International Journal of Environmental Research and Public Health
Background: This study aimed to observe the effects of a fast acute ascent to simulated high alti... more Background: This study aimed to observe the effects of a fast acute ascent to simulated high altitudes on cardiovascular function both in the main arteries and in peripheral circulation. Methods: We examined 17 healthy volunteers, between 18 and 50 years old, at sea level, at 3842 m of hypobaric hypoxia and after return to sea level. Cardiac output (CO) was measured with Doppler transthoracic echocardiography. Oxygen delivery was estimated as the product of CO and peripheral oxygen saturation (SpO2). The brachial artery’s flow-mediated dilation (FMD) was measured with the ultrasound method. Post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography. Results: During altitude stay, peripheral oxygen saturation decreased (84.9 ± 4.2% of pre-ascent values; p < 0.001). None of the volunteers presented any hypoxia-related symptoms. Nevertheless, an increase in cardiac output (143.2 ± 36.2% of pre-ascent values, p < 0.001) and oxygen delivery index (120.6 ± 28.4...
Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc, 2013
OBJECTIVE Scuba and breath-hold divers are compared to investigate whether endothelial response c... more OBJECTIVE Scuba and breath-hold divers are compared to investigate whether endothelial response changes are similar despite different exposure(s) to hyperoxia. DESIGN 14 divers (nine scuba and five breath-holding) performed either one scuba dive (25m/25 minutes) or successive breath-hold dives at a depth of 20 meters, adding up to 25 minutes of immersion time in a diving pool. Flow-mediated dilation (FMD) was measured using echography. Peripheral post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography and plasmatic nitric oxide (NO) concentration using a nitrate/nitrite colorimetric assay kit. RESULTS The FMD decreased in both groups. PORH was reduced in scuba divers but increased in breath-hold divers. No difference in circulating NO was observed for the scuba group. Opposingly, an increase in circulating NO was observed for the breath-hold group. CONCLUSION Some cardiovascular effects can be explained by interaction between NO and superoxide anion during b...
Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc
Scuba and breath-hold divers are compared to investigate whether endothelial response changes are... more Scuba and breath-hold divers are compared to investigate whether endothelial response changes are similar despite different exposure(s) to hyperoxia. 14 divers (nine scuba and five breath-holding) performed either one scuba dive (25m/25 minutes) or successive breath-hold dives at a depth of 20 meters, adding up to 25 minutes of immersion time in a diving pool. Flow-mediated dilation (FMD) was measured using echography. Peripheral post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography and plasmatic nitric oxide (NO) concentration using a nitrate/nitrite colorimetric assay kit. The FMD decreased in both groups. PORH was reduced in scuba divers but increased in breath-hold divers. No difference in circulating NO was observed for the scuba group. Opposingly, an increase in circulating NO was observed for the breath-hold group. Some cardiovascular effects can be explained by interaction between NO and superoxide anion during both types of diving ending to less N...
Objective: Scuba and breath-hold divers are compared to investigate whether endothelial response ... more Objective: Scuba and breath-hold divers are compared to investigate whether endothelial response changes are similar despite different exposure(s) to hyperoxia. Design: 14 divers (nine scuba and five breath-holding) performed either one scuba dive (25m/25 minutes) or successive breath-hold dives at a depth of 20 meters, adding up to 25 minutes of immersion time in a diving pool. Flow-mediated dilation (FMD) was measured using echography. Peripheral post-occlusion reactive hyperemia (PORH) was assessed by digital plethysmography and plasmatic nitric oxide (NO) concentration using a nitrate/nitrite colorimetric assay kit. Results: The FMD decreased in both groups. PORH was reduced in scuba divers but increased in breathhold divers. No difference in circulating NO was observed for the scuba group. Opposingly, an increase in circulating NO was observed for the breath-hold group. Conclusion: Some cardiovascular effects can be explained by interaction between NO and superoxide anion during both types of diving ending to less NO availability and reducing FMD. The increased circulating NO in the breath-hold group can be caused by physical exercise. The opposite effects found between FMD and PORH in the breath-hold group can be assimilated to a greater responsiveness to circulating NO in small arteries than in large arteries. _____________________________________________________________________________________________
Diving and hyperbaric medicine, 2014
INTRODUCTION 'Decompression stress' is commonly evaluated by scoring circulating bubble n... more INTRODUCTION 'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profiles. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. METHODS Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were...
Diving and hyperbaric medicine, 2014
Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. ... more Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. The use of portable 2D echocardiography and 'frame-based' bubble counting as a tool to evaluate diving decompression stress. Diving and Hyperbaric Medicine. 2014 March;44(1):5-13.) Introduction: 'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profi les. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. Methods: Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were randomly repeated. A Wilcoxon Spearman rho calculation was used to assess test-retest reliability of each rater for the repeated still frames. For the video images, weighted kappa statistics, with linear and quadratic weightings, were calculated to measure agreement between raters for the Eftedal and Brubakk method. Bland-Altman plots and intra-class correlation coeffi cients were used to measure agreement between raters for the frame-based counting method. Results: Frame-based counting showed a better inter-rater agreement than the Eftedal and Brubakk grading, even with relatively inexperienced assessors, and has good intra-and inter-rater reliability. Conclusion: Frame-based bubble counting could be used to evaluate post-dive decompression stress, and offers possibilities for computer-automated algorithms to allow near-real-time counting.
Medical hypotheses, Jan 28, 2015
&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;... more &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot;Cutis Marmorata&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot; skin symptoms after diving, most frequently in the form of an itching or painful cutaneous red-bluish discoloration are commonly regarded as a mild form of decompression sickness (DCS), and treated with oxygen inhalation without reverting to hyperbaric recompression treatment. It has been observed that the occurrence of Cutis Marmorata is frequently associated with the presence of a Patent Foramen Ovale (PFO) of the heart, and indeed, with a properly executed contrast echocardiographic technique, these patients have an almost 100% prevalence of PFO. Only occasionally, Cutis Marmorata is accompanied by other symptoms of DCS. These symptoms usually are in the form of visual distortions, vertigo, or mild, vague but generalized cerebral dysfunction (such as abnormal fatigue, clumsiness, concentration problems). The pathogenesis of these other manifestations is clearly emboligenic, and we hypothesize that Cutis Marmorata is also a manifestation of gas bubbles embolizing the brain stem: the site of autonomic nervous system regulation of skin blood vessel dilation and constriction. The consequences of this hypothesis are that Cutis Marmorata skin decompression sickness should no longer be considered a mild, innocuous form but rather a serious, neurological form and treated accordingly.
Diving and hyperbaric medicine, 2014
Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. ... more Germonpré P, Papadopoulou V, Hemelryck W, Obeid G, Lafère P, Eckersley RJ, Tang M-X, Balestra C. The use of portable 2D echocardiography and 'frame-based' bubble counting as a tool to evaluate diving decompression stress. Diving and Hyperbaric Medicine. 2014 March;44(1):5-13.) Introduction: 'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profi les. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. Methods: Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were randomly repeated. A Wilcoxon Spearman rho calculation was used to assess test-retest reliability of each rater for the repeated still frames. For the video images, weighted kappa statistics, with linear and quadratic weightings, were calculated to measure agreement between raters for the Eftedal and Brubakk method. Bland-Altman plots and intra-class correlation coeffi cients were used to measure agreement between raters for the frame-based counting method. Results: Frame-based counting showed a better inter-rater agreement than the Eftedal and Brubakk grading, even with relatively inexperienced assessors, and has good intra-and inter-rater reliability. Conclusion: Frame-based bubble counting could be used to evaluate post-dive decompression stress, and offers possibilities for computer-automated algorithms to allow near-real-time counting.