Juan Torres - Academia.edu (original) (raw)

Uploads

Papers by Juan Torres

Research paper thumbnail of Influence of Fiber Content on Shear Capacity of Steel Fiber Reinforced Concrete Beams

For shear-critical structural elements where the use of stirrups is not desirable, such as slabs ... more For shear-critical structural elements where the use of stirrups is not desirable, such as slabs or beams with reinforcement congestion, steel fibers can be used as shear reinforcement. The contribution of the steel fibers to the shear capacity lies in the action of the steel fibers bridging the shear crack, which increases the shear capacity and prevents a brittle failure mode. This study evaluates the effect of the amount of fibers in a concrete mix on the shear capacity of steel fiber reinforced concrete beams with mild steel tension reinforcement and without stirrups. For this purpose, twelve beams were tested. Five different fiber volume fractions were studied: 0.0%, 0.3%, 0.6%, 0.9%, and 1.2%. For each different steel fiber concrete mix, the concrete compressive strength was determined on cylinders and the tensile strength was determined in a flexural test on beam specimens. Additionally, the influence of fibers on the shear capacity is analyzed based on results reported in th...

Research paper thumbnail of Influence of Fiber Content on Shear Capacity of Steel Fiber Reinforced Concrete Beams

For shear-critical structural elements where the use of stirrups is not desirable, such as slabs ... more For shear-critical structural elements where the use of stirrups is not desirable, such as slabs or beams with reinforcement congestion, steel fibers can be used as shear reinforcement. The contribution of the steel fibers to the shear capacity lies in the action of the steel fibers bridging the shear crack, which increases the shear capacity and prevents a brittle failure mode. This study evaluates the effect of the amount of fibers in a concrete mix on the shear capacity of steel fiber reinforced concrete beams with mild steel tension reinforcement and without stirrups. For this purpose, twelve beams were tested. Five different fiber volume fractions were studied: 0.0%, 0.3%, 0.6%, 0.9%, and 1.2%. For each different steel fiber concrete mix, the concrete compressive strength was determined on cylinders and the tensile strength was determined in a flexural test on beam specimens. Additionally, the influence of fibers on the shear capacity is analyzed based on results reported in th...

Log In