BMC Medical Imaging
Background Multi slice computed tomography (MSCT) is the most common used method in middle ear im... more Background Multi slice computed tomography (MSCT) is the most common used method in middle ear imaging. However, MSCT lacks the ability to distinguish the ossicular chain microstructures in detail resulting in poorer diagnostic outcomes. Novel cone beam computed tomography (CBCT) devices’ image resolution is, on the other hand, better than MSCT resolution. The aim of this study was to optimize imaging parameters of a novel full body CBCT device to obtain optimal contrast to noise ratio (CNR) with low effective dose, and to optimize its clinical usability. Methods Imaging of five anonymous excised human cadaver temporal bones, the acquisition of the effective doses and the CNR measurements were performed for images acquired on using Planmed XFI® full body CBCT device (Planmed Oy, Helsinki, Finland) with a voxel size of 75 µm. All images acquired from the specimens using 10 different imaging protocols varying from their tube current exposure time product (mAs) and tube voltage (kVp) w...
Dento maxillo facial radiology, Jan 3, 2018
The primary aim was to evaluate the effective dose for a full size panoramic image and nine diffe... more The primary aim was to evaluate the effective dose for a full size panoramic image and nine different panoramic protocols using collimation. The secondary aim was to estimate possible reduction of effective dose in clinical situations. Effective dose, according to International Commission on Radiological Protection (ICRP) 2007, were determined for a full size panoramic image and nine different panoramic protocols applying collimation on an anthropomorphic Rando phantom, using metal-oxide semiconductor field-effect transistor (MOSFET) dosimeters. The collimation protocols were chosen based on common diagnostic questions. Ten exposures were made for each protocol using a Planmeca ProMax 2D (Helsinki, Finland). The mean effective doses were calculated according to clinical default exposure settings and compared for all protocols. A retrospective analysis of 252 referrals to a specialist clinic in dentomaxillofacial radiology assessed usability and dose reduction applying nine different...
Journal of applied clinical medical physics, Jul 8, 2015
The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect tra... more The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomo...
Dento maxillo facial radiology, Jan 7, 2017
To assess the impact of supine, prone and oblique patient imaging positions on the image quality,... more To assess the impact of supine, prone and oblique patient imaging positions on the image quality, contrast-to-noise ratio (CNR) and figure of merit (FOM) value in the maxillofacial region using a CBCT scanner. Furthermore, the CBCT supine images were compared with supine multislice CT (MSCT) images. One fresh frozen cadaver head was scanned in prone, supine and oblique imaging positions using a mobile CBCT scanner. MSCT images of the head were acquired in a supine position. Two radiologists graded the CBCT and MSCT images at ten different anatomical sites according to their image quality using a six-point scale. The CNR and FOM values were calculated at two different anatomical sites on the CBCT and MSCT images. The best image quality was achieved in the prone imaging position for sinus, mandible and maxilla, followed by the supine and oblique imaging positions. 12-mA prone images presented high delineation scores for all anatomical landmarks, except for the ear region (carotid cana...
International Journal of Computer Assisted Radiology and Surgery, 2016
Purpose Medical additive manufacturing requires standard tessellation language (STL) models. Such... more Purpose Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. Method One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). Results The intra-and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients >0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-B Maureen van Eijnatten
Journal of foot and ankle research, 2015
The aim of this study was to assess and compare the effective doses (ICRP 103) in the ankle regio... more The aim of this study was to assess and compare the effective doses (ICRP 103) in the ankle region of X-ray imaging resulting from a multi slice computed tomography (MSCT) device, two cone beam CT (CBCT) devices and one conventional x-ray device. Organ dose measurements were performed using 20 metal oxide field effect transistor (MOSFET) dosimeters that were placed in a custom made anthropomorphic RANDO ankle phantom. The following scanners were assessed in this study: Siemens Sensation Open 24-slice MSCT-scanner (120 kVp, 54 mAs), NewTom 5G CBCT scanner (110 kVp, 2.3 - 59 mAs), Planmed Verity CBCT-scanner (90 kVp, 48 mAs), Shimadzu FH-21 HR direct radiography equipment (AP + LAT), (57 kVp, 16 mAs). Measurements of the MSCT device resulted in 21.4 μSv effective dose. The effective doses of CBCTs were between 1.9 μSv and 14.3 μSv for NewTom 5G and 6.0 μSv for Planmed Verity. Effective doses for the Shimadzu FH-21 HR conventional radiography were 1.0 μSv (LAT) and 0.5 μSv (AP), respec...
Oral surgery, oral medicine, oral pathology and oral radiology, 2014
The objectives of this study were to assess the organ and effective doses (International Commissi... more The objectives of this study were to assess the organ and effective doses (International Commission on Radiological Protection [ICRP] 103 standard) resulting from supine, prone, and oblique phantom positions in the maxillofacial region using a novel cone beam computed tomography (CBCT) device and to compare the results with conventional dental CBCT and multislice computed tomography (MSCT) devices. Measurements were performed using an anthropomorphic RANDO head phantom (Radiation Analogue Dosimetry System) with 20 MOSFET (metal-oxide-semiconductor field-effect transistor) dosimeters placed in the most radiosensitive maxillofacial organs. Effective doses were measured in 3 phantom positions using a combined extremity and maxillofacial CBCT device: the Planmed Verity CBCT scanner. Reference values were measured in the upright position with 2 CBCT devices and in the prone position with one MSCT scanner. The Planmed Verity CBCT scanner effective doses were 247 μSv in supine, 192 μSv in ...
Dento maxillo facial radiology, 2014
The objective of this study was to compare the performance of metal oxide semiconductor field-eff... more The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth...
Acta Oto-Laryngologica, 2015
Conclusions: The present experimental setup of high spatial resolution cone-beam computed tomogra... more Conclusions: The present experimental setup of high spatial resolution cone-beam computed tomography (CBCT) showed advantages of demonstrating the critical landmarks of the cochlea in identifying the position of intracochlear electrode contacts and has the potential for clinical application in cochlear implant (CI) surgery. Objective: To evaluate a newly developed CBCT system in defining CI electrode array in human temporal bone and cochlear morphological variation. Methods: Standard electrode, flexible tip electrode (Flex28), and an experimental electrode array with 36 contacts from MED-EL were implanted into the cochleae of six human temporal bones through an atraumatic round window membrane insertion. The cochleae were imaged with 900 frames using an experimental setup based on a CBCT scanner installed with Superior SXR 130-15-0.5 X-ray tube in combination with filtration of copper and aluminum. Results: In all temporal bones, the landmarks of the cochlea, modiolus, osseous spiral lamina, round window niche, and stapes were demonstrated at an average level of 3.4-4.5. The contacts of electrode arrays were clearly shown to locate in the scala tympani. There was a linear correlation between the 'A' value and cochlea height, and between the A value and actual electrode insertion length for the first 360 insertion depth.
Radiation Protection Dosimetry, 2013
The objective of this study was to assess and compare the organ and effective doses in the knee a... more The objective of this study was to assess and compare the organ and effective doses in the knee area resulting from different commercially available multislice computed tomography devices (MSCT), one cone beam computed tomography device (CBCT) and one conventional X-ray radiography device using MOSFET dosemeters and an anthropomorphic RANDO knee phantom. Measurements of the MSCT devices resulted in effective doses ranging between 27 and 48 Sv. The CBCT measurements resulted in an effective dose of 12.6 Sv. The effective doses attained using the conventional radiography device were 1.8 Sv for lateral and 1.2 Sv for anterior-posterior projections. The effective dose resulting from conventional radiography was considerably lower than those recorded for the CBCT and MSCT devices. The MSCT effective dose results were two to four times higher than those measured on the CBCT device. This study demonstrates that CBCT can be regarded as a potential low-dose 3D imaging technique for knee examinations.
Journal of Applied Clinical Medical Physics, 2021
The aim of the study was to estimate and to compare effective doses in the elbow region resulting... more The aim of the study was to estimate and to compare effective doses in the elbow region resulting from four different x‐ray imaging modalities. Absorbed organ doses were measured using 11 metal oxide field effect transistor (MOSFET) dosimeters that were placed in a custom‐made anthropomorphic elbow RANDO phantom. Examinations were performed using Shimadzu FH‐21 HR radiography device, Siemens Sensation Open 24‐slice MSCT‐device, NewTom 5G CBCT device, and Planmed Verity CBCT device, and the effective doses were calculated according to ICRP 103 recommendations. The effective dose for the conventional radiographic device was 1.5 µSv. The effective dose for the NewTom 5G CBCT ranged between 2.0 and 6.7 µSv, for the Planmed Verity CBCT device 2.6 µSv and for the Siemens Sensation MSCT device 37.4 µSv. Compared with conventional 2D radiography, this study demonstrated a 1.4–4.6 fold increase in effective dose for CBCT and 25‐fold dose for standard MSCT protocols. When compared with 3D CBC...
Journal of Radiation Research, 2013
When performing dose measurements on an X-ray device with multiple angles of irradiation, it is n... more When performing dose measurements on an X-ray device with multiple angles of irradiation, it is necessary to take the angular dependence of metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters into account. The objective of this study was to investigate the angular sensitivity dependence of MOSFET dosimeters in three rotational axes measured free-in-air and in soft-tissue equivalent material using dental photon energy. Free-in-air dose measurements were performed with three MOSFET dosimeters attached to a carbon fibre holder. Soft tissue measurements were performed with three MOSFET dosimeters placed in a polymethylmethacrylate (PMMA) phantom. All measurements were made in the isocenter of a dental conebeam computed tomography (CBCT) scanner using 5º angular increments in the three rotational axes: axial, normal-to-axial and tangent-to-axial. The measurements were referenced to a RADCAL 1015 dosimeter. The angular sensitivity free-in-air (1 SD) was 3.7 ± 0.5 mV/mGy for axial, 3.8 ± 0.6 mV/mGy for normalto-axial and 3.6 ± 0.6 mV/mGy for tangent-to-axial rotation. The angular sensitivity in the PMMA phantom was 3.1 ± 0.1 mV/mGy for axial, 3.3 ± 0.2 mV/mGy for normal-to-axial and 3.4 ± 0.2 mV/mGy for tangentto-axial rotation. The angular sensitivity variations are considerably smaller in PMMA due to the smoothing effect of the scattered radiation. The largest decreases from the isotropic response were observed free-in-air at 90°(distal tip) and 270°(wire base) in the normal-to-axial and tangent-to-axial rotations, respectively. MOSFET dosimeters provide us with a versatile dosimetric method for dental radiology. However, due to the observed variation in angular sensitivity, MOSFET dosimeters should always be calibrated in the actual clinical settings for the beam geometry and angular range of the CBCT exposure.
BMC Medical Imaging
Background Multi slice computed tomography (MSCT) is the most common used method in middle ear im... more Background Multi slice computed tomography (MSCT) is the most common used method in middle ear imaging. However, MSCT lacks the ability to distinguish the ossicular chain microstructures in detail resulting in poorer diagnostic outcomes. Novel cone beam computed tomography (CBCT) devices’ image resolution is, on the other hand, better than MSCT resolution. The aim of this study was to optimize imaging parameters of a novel full body CBCT device to obtain optimal contrast to noise ratio (CNR) with low effective dose, and to optimize its clinical usability. Methods Imaging of five anonymous excised human cadaver temporal bones, the acquisition of the effective doses and the CNR measurements were performed for images acquired on using Planmed XFI® full body CBCT device (Planmed Oy, Helsinki, Finland) with a voxel size of 75 µm. All images acquired from the specimens using 10 different imaging protocols varying from their tube current exposure time product (mAs) and tube voltage (kVp) w...
Dento maxillo facial radiology, Jan 3, 2018
The primary aim was to evaluate the effective dose for a full size panoramic image and nine diffe... more The primary aim was to evaluate the effective dose for a full size panoramic image and nine different panoramic protocols using collimation. The secondary aim was to estimate possible reduction of effective dose in clinical situations. Effective dose, according to International Commission on Radiological Protection (ICRP) 2007, were determined for a full size panoramic image and nine different panoramic protocols applying collimation on an anthropomorphic Rando phantom, using metal-oxide semiconductor field-effect transistor (MOSFET) dosimeters. The collimation protocols were chosen based on common diagnostic questions. Ten exposures were made for each protocol using a Planmeca ProMax 2D (Helsinki, Finland). The mean effective doses were calculated according to clinical default exposure settings and compared for all protocols. A retrospective analysis of 252 referrals to a specialist clinic in dentomaxillofacial radiology assessed usability and dose reduction applying nine different...
Journal of applied clinical medical physics, Jul 8, 2015
The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect tra... more The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomo...
Dento maxillo facial radiology, Jan 7, 2017
To assess the impact of supine, prone and oblique patient imaging positions on the image quality,... more To assess the impact of supine, prone and oblique patient imaging positions on the image quality, contrast-to-noise ratio (CNR) and figure of merit (FOM) value in the maxillofacial region using a CBCT scanner. Furthermore, the CBCT supine images were compared with supine multislice CT (MSCT) images. One fresh frozen cadaver head was scanned in prone, supine and oblique imaging positions using a mobile CBCT scanner. MSCT images of the head were acquired in a supine position. Two radiologists graded the CBCT and MSCT images at ten different anatomical sites according to their image quality using a six-point scale. The CNR and FOM values were calculated at two different anatomical sites on the CBCT and MSCT images. The best image quality was achieved in the prone imaging position for sinus, mandible and maxilla, followed by the supine and oblique imaging positions. 12-mA prone images presented high delineation scores for all anatomical landmarks, except for the ear region (carotid cana...
International Journal of Computer Assisted Radiology and Surgery, 2016
Purpose Medical additive manufacturing requires standard tessellation language (STL) models. Such... more Purpose Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. Method One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). Results The intra-and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients >0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-B Maureen van Eijnatten
Journal of foot and ankle research, 2015
The aim of this study was to assess and compare the effective doses (ICRP 103) in the ankle regio... more The aim of this study was to assess and compare the effective doses (ICRP 103) in the ankle region of X-ray imaging resulting from a multi slice computed tomography (MSCT) device, two cone beam CT (CBCT) devices and one conventional x-ray device. Organ dose measurements were performed using 20 metal oxide field effect transistor (MOSFET) dosimeters that were placed in a custom made anthropomorphic RANDO ankle phantom. The following scanners were assessed in this study: Siemens Sensation Open 24-slice MSCT-scanner (120 kVp, 54 mAs), NewTom 5G CBCT scanner (110 kVp, 2.3 - 59 mAs), Planmed Verity CBCT-scanner (90 kVp, 48 mAs), Shimadzu FH-21 HR direct radiography equipment (AP + LAT), (57 kVp, 16 mAs). Measurements of the MSCT device resulted in 21.4 μSv effective dose. The effective doses of CBCTs were between 1.9 μSv and 14.3 μSv for NewTom 5G and 6.0 μSv for Planmed Verity. Effective doses for the Shimadzu FH-21 HR conventional radiography were 1.0 μSv (LAT) and 0.5 μSv (AP), respec...
Oral surgery, oral medicine, oral pathology and oral radiology, 2014
The objectives of this study were to assess the organ and effective doses (International Commissi... more The objectives of this study were to assess the organ and effective doses (International Commission on Radiological Protection [ICRP] 103 standard) resulting from supine, prone, and oblique phantom positions in the maxillofacial region using a novel cone beam computed tomography (CBCT) device and to compare the results with conventional dental CBCT and multislice computed tomography (MSCT) devices. Measurements were performed using an anthropomorphic RANDO head phantom (Radiation Analogue Dosimetry System) with 20 MOSFET (metal-oxide-semiconductor field-effect transistor) dosimeters placed in the most radiosensitive maxillofacial organs. Effective doses were measured in 3 phantom positions using a combined extremity and maxillofacial CBCT device: the Planmed Verity CBCT scanner. Reference values were measured in the upright position with 2 CBCT devices and in the prone position with one MSCT scanner. The Planmed Verity CBCT scanner effective doses were 247 μSv in supine, 192 μSv in ...
Dento maxillo facial radiology, 2014
The objective of this study was to compare the performance of metal oxide semiconductor field-eff... more The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth...
Acta Oto-Laryngologica, 2015
Conclusions: The present experimental setup of high spatial resolution cone-beam computed tomogra... more Conclusions: The present experimental setup of high spatial resolution cone-beam computed tomography (CBCT) showed advantages of demonstrating the critical landmarks of the cochlea in identifying the position of intracochlear electrode contacts and has the potential for clinical application in cochlear implant (CI) surgery. Objective: To evaluate a newly developed CBCT system in defining CI electrode array in human temporal bone and cochlear morphological variation. Methods: Standard electrode, flexible tip electrode (Flex28), and an experimental electrode array with 36 contacts from MED-EL were implanted into the cochleae of six human temporal bones through an atraumatic round window membrane insertion. The cochleae were imaged with 900 frames using an experimental setup based on a CBCT scanner installed with Superior SXR 130-15-0.5 X-ray tube in combination with filtration of copper and aluminum. Results: In all temporal bones, the landmarks of the cochlea, modiolus, osseous spiral lamina, round window niche, and stapes were demonstrated at an average level of 3.4-4.5. The contacts of electrode arrays were clearly shown to locate in the scala tympani. There was a linear correlation between the 'A' value and cochlea height, and between the A value and actual electrode insertion length for the first 360 insertion depth.
Radiation Protection Dosimetry, 2013
The objective of this study was to assess and compare the organ and effective doses in the knee a... more The objective of this study was to assess and compare the organ and effective doses in the knee area resulting from different commercially available multislice computed tomography devices (MSCT), one cone beam computed tomography device (CBCT) and one conventional X-ray radiography device using MOSFET dosemeters and an anthropomorphic RANDO knee phantom. Measurements of the MSCT devices resulted in effective doses ranging between 27 and 48 Sv. The CBCT measurements resulted in an effective dose of 12.6 Sv. The effective doses attained using the conventional radiography device were 1.8 Sv for lateral and 1.2 Sv for anterior-posterior projections. The effective dose resulting from conventional radiography was considerably lower than those recorded for the CBCT and MSCT devices. The MSCT effective dose results were two to four times higher than those measured on the CBCT device. This study demonstrates that CBCT can be regarded as a potential low-dose 3D imaging technique for knee examinations.
Journal of Applied Clinical Medical Physics, 2021
The aim of the study was to estimate and to compare effective doses in the elbow region resulting... more The aim of the study was to estimate and to compare effective doses in the elbow region resulting from four different x‐ray imaging modalities. Absorbed organ doses were measured using 11 metal oxide field effect transistor (MOSFET) dosimeters that were placed in a custom‐made anthropomorphic elbow RANDO phantom. Examinations were performed using Shimadzu FH‐21 HR radiography device, Siemens Sensation Open 24‐slice MSCT‐device, NewTom 5G CBCT device, and Planmed Verity CBCT device, and the effective doses were calculated according to ICRP 103 recommendations. The effective dose for the conventional radiographic device was 1.5 µSv. The effective dose for the NewTom 5G CBCT ranged between 2.0 and 6.7 µSv, for the Planmed Verity CBCT device 2.6 µSv and for the Siemens Sensation MSCT device 37.4 µSv. Compared with conventional 2D radiography, this study demonstrated a 1.4–4.6 fold increase in effective dose for CBCT and 25‐fold dose for standard MSCT protocols. When compared with 3D CBC...
Journal of Radiation Research, 2013
When performing dose measurements on an X-ray device with multiple angles of irradiation, it is n... more When performing dose measurements on an X-ray device with multiple angles of irradiation, it is necessary to take the angular dependence of metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters into account. The objective of this study was to investigate the angular sensitivity dependence of MOSFET dosimeters in three rotational axes measured free-in-air and in soft-tissue equivalent material using dental photon energy. Free-in-air dose measurements were performed with three MOSFET dosimeters attached to a carbon fibre holder. Soft tissue measurements were performed with three MOSFET dosimeters placed in a polymethylmethacrylate (PMMA) phantom. All measurements were made in the isocenter of a dental conebeam computed tomography (CBCT) scanner using 5º angular increments in the three rotational axes: axial, normal-to-axial and tangent-to-axial. The measurements were referenced to a RADCAL 1015 dosimeter. The angular sensitivity free-in-air (1 SD) was 3.7 ± 0.5 mV/mGy for axial, 3.8 ± 0.6 mV/mGy for normalto-axial and 3.6 ± 0.6 mV/mGy for tangent-to-axial rotation. The angular sensitivity in the PMMA phantom was 3.1 ± 0.1 mV/mGy for axial, 3.3 ± 0.2 mV/mGy for normal-to-axial and 3.4 ± 0.2 mV/mGy for tangentto-axial rotation. The angular sensitivity variations are considerably smaller in PMMA due to the smoothing effect of the scattered radiation. The largest decreases from the isotropic response were observed free-in-air at 90°(distal tip) and 270°(wire base) in the normal-to-axial and tangent-to-axial rotations, respectively. MOSFET dosimeters provide us with a versatile dosimetric method for dental radiology. However, due to the observed variation in angular sensitivity, MOSFET dosimeters should always be calibrated in the actual clinical settings for the beam geometry and angular range of the CBCT exposure.