Kenneth Hoffer - Academia.edu (original) (raw)

Uploads

Papers by Kenneth Hoffer

Research paper thumbnail of Preliminary report of independent testing of intraocular lenses

American Intra-Ocular Implant Society Journal, 1977

Research paper thumbnail of Selection of Lens Power for Implantation in Infants and Children

American Intra-Ocular Implant Society Newsletter, 1975

Research paper thumbnail of Accidental Suture Engagement by Posterior Loop While Inserting a Medallion® Lens

American Intra-Ocular Implant Society Newsletter, 1975

Research paper thumbnail of Programs

American Intra-Ocular Implant Society Journal, 1977

Research paper thumbnail of Obtaining the Facts

American Intra-Ocular Implant Society Newsletter, 1975

Research paper thumbnail of Scientific Advisory Board Meeting

American Intra-Ocular Implant Society Journal, 1978

Research paper thumbnail of Errors in IOL power study methodology

European Journal of Ophthalmology, 2015

Research paper thumbnail of Chapter-04 My Preferential Approach for IOL Power Calculation after Previous Refractive Surgery

Lens Surgery after Previous Refractive Surgery, 2011

Research paper thumbnail of Chapter-14 IOL Power Calculations

Manual of Eye Examination and Diagnosis-An Elaborated Ophthalmology, 2008

Research paper thumbnail of Cataract surgical problem: response #7

J Cataract Refract Surg, 2000

Research paper thumbnail of Chapter-08 Intraocular Lens Power Calculation

Phaco Without The Phaco, 2005

Research paper thumbnail of Chapter-04 Intraocular Lens Power Calculation and Ocular Biometry

Phacoemulsification Surgery, 2005

Research paper thumbnail of Chapter-52 Intraocular Lens Calculation after Prior Refractive Surgery

Manual of Eye Examination and Diagnosis-An Elaborated Ophthalmology, 2008

Research paper thumbnail of A simple lens power calculation program for the HP-67 and HP-97 calculators

Journal - American Intra-Ocular Implant Society, 1978

Research paper thumbnail of Programs

Research paper thumbnail of The Evolution of the Intraocular Lens

Cataract Surgery, 2010

... Ebitzweg, Germany). He first presented this lens publicly in Middelburg on the Isle of Walche... more ... Ebitzweg, Germany). He first presented this lens publicly in Middelburg on the Isle of Walcheren on October 3, 1958. The term" pseudophakia" to indicate the presence of an IOL was inaugurated by Binkhorst at Oxford in 1959. The ...

Research paper thumbnail of Rapid Fibrosis of ORC Stableflex Haptics

American Intra-Ocular Implant Society Journal, 1984

Research paper thumbnail of Preoperative evaluation of the cataractous patient

Survey of Ophthalmology, 1984

The author reviews the methods and considerations involved in evaluating the cataractous patient.... more The author reviews the methods and considerations involved in evaluating the cataractous patient. A well documented work-up is essential both to determine the need for surgery and to be able to inform the patient of possible outcomes. Many subjective factors influencing the decision to operate are also taken into account. The decision must be made on the basis of the work-up, a complete evaluation of the patient's complaints, lifestyle, and needs, and consideration of the risk factors involved. Indications and contraindications for intraocular lens implantation are examined. The subject of calculating lens power is covered in detail. The use of endothelial cell counts is also examined.

Research paper thumbnail of Triple Procedure for Intraocular Lens Exchange

Archives of Ophthalmology, 1987

Research paper thumbnail of A Review of the Sonometrics DBR Unit and the Binkhorst Formula

Archives of Ophthalmology, 1982

Research paper thumbnail of Preliminary report of independent testing of intraocular lenses

American Intra-Ocular Implant Society Journal, 1977

Research paper thumbnail of Selection of Lens Power for Implantation in Infants and Children

American Intra-Ocular Implant Society Newsletter, 1975

Research paper thumbnail of Accidental Suture Engagement by Posterior Loop While Inserting a Medallion® Lens

American Intra-Ocular Implant Society Newsletter, 1975

Research paper thumbnail of Programs

American Intra-Ocular Implant Society Journal, 1977

Research paper thumbnail of Obtaining the Facts

American Intra-Ocular Implant Society Newsletter, 1975

Research paper thumbnail of Scientific Advisory Board Meeting

American Intra-Ocular Implant Society Journal, 1978

Research paper thumbnail of Errors in IOL power study methodology

European Journal of Ophthalmology, 2015

Research paper thumbnail of Chapter-04 My Preferential Approach for IOL Power Calculation after Previous Refractive Surgery

Lens Surgery after Previous Refractive Surgery, 2011

Research paper thumbnail of Chapter-14 IOL Power Calculations

Manual of Eye Examination and Diagnosis-An Elaborated Ophthalmology, 2008

Research paper thumbnail of Cataract surgical problem: response #7

J Cataract Refract Surg, 2000

Research paper thumbnail of Chapter-08 Intraocular Lens Power Calculation

Phaco Without The Phaco, 2005

Research paper thumbnail of Chapter-04 Intraocular Lens Power Calculation and Ocular Biometry

Phacoemulsification Surgery, 2005

Research paper thumbnail of Chapter-52 Intraocular Lens Calculation after Prior Refractive Surgery

Manual of Eye Examination and Diagnosis-An Elaborated Ophthalmology, 2008

Research paper thumbnail of A simple lens power calculation program for the HP-67 and HP-97 calculators

Journal - American Intra-Ocular Implant Society, 1978

Research paper thumbnail of Programs

Research paper thumbnail of The Evolution of the Intraocular Lens

Cataract Surgery, 2010

... Ebitzweg, Germany). He first presented this lens publicly in Middelburg on the Isle of Walche... more ... Ebitzweg, Germany). He first presented this lens publicly in Middelburg on the Isle of Walcheren on October 3, 1958. The term" pseudophakia" to indicate the presence of an IOL was inaugurated by Binkhorst at Oxford in 1959. The ...

Research paper thumbnail of Rapid Fibrosis of ORC Stableflex Haptics

American Intra-Ocular Implant Society Journal, 1984

Research paper thumbnail of Preoperative evaluation of the cataractous patient

Survey of Ophthalmology, 1984

The author reviews the methods and considerations involved in evaluating the cataractous patient.... more The author reviews the methods and considerations involved in evaluating the cataractous patient. A well documented work-up is essential both to determine the need for surgery and to be able to inform the patient of possible outcomes. Many subjective factors influencing the decision to operate are also taken into account. The decision must be made on the basis of the work-up, a complete evaluation of the patient's complaints, lifestyle, and needs, and consideration of the risk factors involved. Indications and contraindications for intraocular lens implantation are examined. The subject of calculating lens power is covered in detail. The use of endothelial cell counts is also examined.

Research paper thumbnail of Triple Procedure for Intraocular Lens Exchange

Archives of Ophthalmology, 1987

Research paper thumbnail of A Review of the Sonometrics DBR Unit and the Binkhorst Formula

Archives of Ophthalmology, 1982

Log In