Michelangelo Morrone - Academia.edu (original) (raw)

Papers by Michelangelo Morrone

Research paper thumbnail of The Effectiveness of Extracorporeal Shock Wave Therapy on Breast Cancer-Related Lymphedema: A Literature Review

Lymphology, Jan 19, 2021

Lymphedema is one of the most dreaded complications related to breast cancer surgery, commonly re... more Lymphedema is one of the most dreaded complications related to breast cancer surgery, commonly resulting in upper limb functional, esthetic, and psychological impairment. The necessity to improve the efficacy of conventional treatments and the promising effect of extracorporeal shock wave therapy (ESWT) on lymphangiogenesis in vitro and animal models, has prompted studies involving women affected by breast cancer-related lymphedema. Since intervention modalities and treatment protocols used are different, a review is necessary to verify the effectiveness of ESWT, evaluating the quality of existing studies and the eventual need for further research. Data were obtained from PubMed, Scopus, Google Scholar, Cochrane Library and PEDro, including articles published until January 2019. Five studies met the inclusion criteria. Evident heterogeneity emerged among selected studies permitting only a purely descriptive analysis of their data and strongly limiting their comparison. When compared to other treatment modalities, ESWT showed a significant effect on measured outcomes. It is clear that further high quality research is necessary to assert with confidence the effects and possible superiority of ESWT over other conservative therapies in the management of breast cancer-related lymphedema.

Research paper thumbnail of A Wearable System Composed of FBG-Based Soft Sensors for Trunk Compensatory Movements Detection in Post-Stroke Hemiplegic Patients

Sensors, 2022

In this study, a novel wearable system for the identification of compensatory trunk movements (CT... more In this study, a novel wearable system for the identification of compensatory trunk movements (CTMs) in post-stroke hemiplegic patients is presented. The device is composed of seven soft sensing elements (SSEs) based on fiber Bragg grating (FBG) technology. Each SSE consists of a single FBG encapsulated into a flexible matrix to enhance the sensor’s robustness and improve its compliance with the human body. The FBG’s small size, light weight, multiplexing capability, and biocompatibility make the proposed wearable system suitable for multi-point measurements without any movement restriction. Firstly, its manufacturing process is presented, together with the SSEs’ mechanical characterization to strain. Results of the metrological characterization showed a linear response of each SSE in the operating range. Then, the feasibility assessment of the proposed system is described. In particular, the device’s capability of detecting CTMs was assessed on 10 healthy volunteers and eight hemip...

Research paper thumbnail of Robotic hand treatment of patients affected by chronic stroke: a monocentric longitudinal pilot study

Journal of biological regulators and homeostatic agents, 2020

Few studies investigated the effects of a robotic treatment in hand motor recovery after stroke. ... more Few studies investigated the effects of a robotic treatment in hand motor recovery after stroke. Aim of the present study was to evaluate the efficacy of treatment by means of Gloreha Sinfonia® robotic glove in hand motor recovery of a chronic stroke sample of patients with different impairment severity. Thirteen chronic stroke subjects were assigned to either active-assisted robotic treatment or passive robotic treatment according to their ability to actively extend wrist for at least 20 degrees. All subjects underwent 20 sessions of treatment with Gloreha Sinfonia® and were evaluated before (T0), after treatment (T1) and after one month (T2) with clinical scales testing motor performance [Motor Power (MP); Fugl Meyer Upper-Extremity (FMUE)] and spasticity [Modified Ashworth Scale (MAS)]. Both groups showed significant motor recovery and spasticity reduction. Further randomized controlled trials with larger samples are needed to confirm our results.

Research paper thumbnail of Perceptive rehabilitation improves postural control in patients with Parkinson’s disease: a single-blind, randomized controlled trial

Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson ... more Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson Disease reporting promising preliminary results for postural balance and pain symptoms. To date, no randomized controlled trial was carried out to compare the effects of perceptive rehabilitation and conventional treatment in patients with Parkinson Disease. AIM: To evaluate whether a perceptive rehabilitation treatment could be more effective than a conventional physical therapy program in improving postural control and gait pattern in patients with Parkinson Disease. DESIGN: Single blind, randomized controlled trial. SETTING: Department of Physical and Rehabilitation Medicine of a University Hospital. POPULATION: Twenty outpatients affected by idiopathic Parkinson Disease at Hoehn and Yahr stage 64 3. METHODS: Recruited patients were divided into two groups: the first one underwent individual treatment with Surfaces for Perceptive Rehabilitation (Su-Per), consisting of rigid wood surfaces supporting deformable latex cones of various dimensions, and the second one received conventional group physical therapy treatment. Each patient underwent a training program consisting of ten, 45-minute sessions, three days a week for 4 consecutive weeks. Each subject was evaluated before treatment, immediately after treatment and at one month of follow-up, by an optoelectronic stereophotogrammetric system for gait and posture analysis, and by a computerized platform for stabilometric assessment. RESULTS: Kyphosis angle decreased after ten sessions of perceptive rehabilitation, thus showing a substantial difference with respect to the control group. No significant differences were found as for gait parameters (cadence, gait speed and stride length) within Su-Per group and between groups. Parameters of static and dynamic evaluation on stabilometric platform failed to demonstrate any statistically relevant difference both within-groups and between-groups. CONCLUSIONS: Perceptive training may help patients affected by Parkinson Disease into restoring a correct midline perception and, in turn, to improve postural control. CLINICAL REHABILITATION IMPACT: Perceptive surfaces represent an alternative to conventional rehabilitation of postural disorders in Parkinson Disease. Further studies are needed to determine if the association of perceptive treatment and active motor training would be useful in improving also gait dexterity

Research paper thumbnail of Validation and Assessment of a Posture Measurement System with Magneto-Inertial Measurement Units

Sensors, 2021

Inappropriate posture and the presence of spinal disorders require specific monitoring systems. I... more Inappropriate posture and the presence of spinal disorders require specific monitoring systems. In clinical settings, posture evaluation is commonly performed with visual observation, electrogoniometers or motion capture systems (MoCaps). Developing a measurement system that can be easily used also in non-structured environments would be highly beneficial for accurate posture monitoring. This work proposes a system based on three magneto-inertial measurement units (MIMU), placed on the backs of seventeen volunteers on the T3, T12 and S1 vertebrae. The reference system used for validation is a stereophotogrammetric motion capture system. The volunteers performed forward bending and sit-to-stand tests. The measured variables for identifying the posture were the kyphosis and the lordosis angles, as well as the range of movement (ROM) of the body segments. The comparison between MIMU and MoCap provided a maximum RMSE of 5.6° for the kyphosis and the lordosis angles. The average lumbo-pe...

Research paper thumbnail of Concurrent validity and inter trial reliability of a single inertial measurement unit for spatial-temporal gait parameter analysis in patients with recent total hip or total knee arthroplasty

Gait & Posture, 2020

Background: Osteoarthritis (OA) is one of the main causes of disability and its frequent hip and ... more Background: Osteoarthritis (OA) is one of the main causes of disability and its frequent hip and knee joint localization requires surgical joint replacement treatment. Patients after total hip (THA) or knee (TKA) arthroplasty often show gait abnormalities, whose comprehension is crucial in order to plan an appropriate rehabilitative treatment. Wearable sensor devices can be a valid tool for gait assessment in clinical practice, being relatively inexpensive and easy to use. Research question: Does the use of crutches influence the ability of a single inertial measurement unit (IMU), placed on the lower trunk, to correctly record the spatial-temporal gait parameters in patients after recent THA or TKA? Methods: 20 patients walking with crutches after recent THA or TKA and 10 healthy subjects were recruited. Each participant was recorded simultaneously with an IMU and with an optoelectronic motion capture system during 5 consecutive walking tests. Results: Intraclass correlation index of spatial-temporal parameters recorded with the IMU showed moderate to excellent reliability results both for healthy subjects (ICC range 0.626-0.897) and for patients (ICC range 0.596-0.951). In terms of concurrent validity, Pearson's r coefficient of healthy subjects, showed strong to very strong levels of correlations for some spatial-temporal parameters (speed, mean cadence, left and right stride length and stride duration) (r range 0.646-0.977) and very week to moderately week levels of correlation for gait cycle phases (swing, stance, single support and double support) (r range 0.390-0.633). Patients' data analysis showed similar results for general spatial-temporal parameters (r range 0.704-0.986) and slightly lower values for gait cycle phases (r range 0.077-0.464). Significance: We can consider the single IMU as a reliable tool for the detection of some spatial-temporal gait parameters. Crutches seem to interfere with the detection of the gait cycle phases.

Research paper thumbnail of A Triple Application of Kinesio Taping Supports Rehabilitation Program for Rotator Cuff Tendinopathy: a Randomized Controlled Trial

Ortopedia Traumatologia Rehabilitacja, 2018

Background. Rotator cuff tendinopathy (RoCT) is a common pathology among adults. Kinesio-taping (... more Background. Rotator cuff tendinopathy (RoCT) is a common pathology among adults. Kinesio-taping (KT) represents a possible rehabilitative treatment. The aim of the present study is to investigate the efficacy of a combination of three different applications of KT combined with a standardized protocol of rehabilitative exercises in reducing pain and in functional recovery in patients affected by RoCT. Materials and methods. 21 patients were enrolled in a real group (RG) and 19 in a sham group (SG). RG received a real KT application and SG received a sham KT application. Both groups received the same rehabilitative protocol. A Numeric Rating Scale (NRS) for shoulder pain, Medical Research Council (MRC) Scales for shoulder strength assessment and Costant Murley Score (CMS) were administered before (T0) and at the end of treatment (T1). Results. Within-group analysis for RG at T1 showed significant improvement in: NRS at-rest (p=0.002), during-movement (p<0.001); CMS (p<0.001); MR...

Research paper thumbnail of The efficacy and safety of using CartiJoint Forte (a combination of glucosamine hydrochloride, chondroitin sulfate and bio-curcumin) with exercise in the treatment of knee osteoarthritis: a randomized, double blind, placebo-controlled study

European journal of physical and rehabilitation medicine, Jan 3, 2016

Knee osteoarthritis (OA) conservative treatment aims to delay cartilage degeneration; chondroprot... more Knee osteoarthritis (OA) conservative treatment aims to delay cartilage degeneration; chondroprotectives represent one approach. A commercially available dietary supplement, CartiJoint Forte, based on glucosamine hydrochloride (GH), chondroitin sulfate (CS) and Bio-Curcumin BCM-95®, was used in this trial. To assess efficacy and safety of CartiJoint Forte combined with physical therapy in treating subjects with knee OA. A multicenter, prospective, randomized, double blind, placebo-controlled clinical trial. Outpatients referred to the Rehabilitation Departments of two University Hospitals. Fifty-three patients were randomly assigned to an experimental group (N=26) or a control group (N=27). Experimental subjects received two tablets of CartiJoint Forte each day for 8 weeks, while those in the control group were provided with a placebo. Three subjects dropped out during the course of the study. The two groups both received 20 sessions of physical therapy during the course of the tria...

Research paper thumbnail of Evaluation of optoelectronic Plethysmography accuracy and precision in recording displacements during quiet breathing simulation

2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2015

Opto-electronic Plethysmography (OEP) is a motion analysis system used to measure chest wall kine... more Opto-electronic Plethysmography (OEP) is a motion analysis system used to measure chest wall kinematics and to indirectly evaluate respiratory volumes during breathing. Its working principle is based on the computation of marker displacements placed on the chest wall. This work aims at evaluating the accuracy and precision of OEP in measuring displacement in the range of human chest wall displacement during quiet breathing. OEP performances were investigated by the use of a fully programmable chest wall simulator (CWS). CWS was programmed to move 10 times its eight shafts in the range of physiological displacement (i.e., between 1 mm and 8 mm) at three different frequencies (i.e., 0.17 Hz, 0.25 Hz, 0.33 Hz). Experiments were performed with the aim to: (i) evaluate OEP accuracy and precision error in recording displacement in the overall calibrated volume and in three sub-volumes, (ii) evaluate the OEP volume measurement accuracy due to the measurement accuracy of linear displacements. OEP showed an accuracy better than 0.08 mm in all trials, considering the whole 2m3 calibrated volume. The mean measurement discrepancy was 0.017 mm. The precision error, expressed as the ratio between measurement uncertainty and the recorded displacement by OEP, was always lower than 0.55%. Volume overestimation due to OEP linear measurement accuracy was always <; 12 mL (<; 3.2% of total volume), considering all settings.

Research paper thumbnail of Optoelectronic plethysmography to evaluate the effect of posture on breathing kinematics in spinal cord injury: a cross sectional study

European journal of physical and rehabilitation medicine, Jan 22, 2015

Spinal cord injured patients often suffer from respiratory muscles impairment. Spirometry studies... more Spinal cord injured patients often suffer from respiratory muscles impairment. Spirometry studies showed that in supine position Vital Capacity increases in such patients since diaphragm increases its inspiratory excursion. To our opinion, however, respiratory kinematics in spinal cord injured patients is disadvantaged in supine position. To evaluate the effect of posture (sitting and supine) on respiratory kinematics in chronic spinal cord injured patients using optoelectronic plethysmography. Cross-sectional study. Outpatients referring to the Movement Analysis Laboratory of a Physical and Rehabilitation Medicine Unit. Twenty chronic spinal cord injured patients (9 tetraplegics, with lesional level ranging from C3 to C7 and 11 paraplegics with lesional level ranging from T1 to T8) and twenty healthy subjects matched for gender, age and smoking habits. All subjects underwent optoelectronic evaluation in sitting and supine position during quiet breathing and hyperventilation. Additi...

Research paper thumbnail of Effectiveness And Feasibility Of A Home-Based Pulmonary Rehabilitation Programme In Postsurgical Lung Cancer Patients

A107. ASSESSMENT, EXERCISE TRAINING AND OUTCOMES, 2012

Research paper thumbnail of Disfunzione respiratoria dei pazienti con mielolesione: dati preliminari della valutazione con pletismografia optoelettronica

Research paper thumbnail of Optoelectronic Plethysmography in Clinical Practice and Research: A Review

Respiration; international review of thoracic diseases, 2017

Optoelectronic plethysmography (OEP) is a non-invasive motion capture method to measure chest wal... more Optoelectronic plethysmography (OEP) is a non-invasive motion capture method to measure chest wall movements and estimate lung volumes. To provide an overview of the clinical findings and research applications of OEP in the assessment of breathing mechanics across populations of healthy and diseased individuals. A bibliographic research was performed with the terms "opto-electronic plethysmography," "optoelectronic plethysmography," and "optoelectronic plethysmograph" in 50 digital library and bibliographic search databases resulting in the selection of 170 studies. OEP has been extensively employed in studies looking at chest wall kinematics and volume changes in chest wall compartments in healthy subjects in relation to age, gender, weight, posture, and different physiological conditions. In infants, OEP has been demonstrated to be a tool to assess disease severity and the response to pharmacological interventions. In chronic obstructive pulmonary dis...

Research paper thumbnail of Perceptive rehabilitation and trunk posture alignment in patients with Parkinson disease: a single blind randomized controlled trial

European journal of physical and rehabilitation medicine, 2016

Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson ... more Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson Disease reporting promising preliminary results for postural balance and pain symptoms. To date, no randomized controlled trial was carried out to compare the effects of perceptive rehabilitation and conventional treatment in patients with Parkinson Disease. To evaluate whether a perceptive rehabilitation treatment could be more effective than a conventional physical therapy program in improving postural control and gait pattern in patients with Parkinson Disease. Single blind, randomized controlled trial. Department of Physical and Rehabilitation Medicine of a University Hospital. Twenty outpatients affected by idiopathic Parkinson Disease at Hoehn and Yahr stage ≤3. Recruited patients were divided into two groups: the first one underwent individual treatment with Surfaces for Perceptive Rehabilitation (Su-Per), consisting of rigid wood surfaces supporting deformable latex cones of vari...

Research paper thumbnail of The Effectiveness of Extracorporeal Shock Wave Therapy on Breast Cancer-Related Lymphedema: A Literature Review

Lymphology, Jan 19, 2021

Lymphedema is one of the most dreaded complications related to breast cancer surgery, commonly re... more Lymphedema is one of the most dreaded complications related to breast cancer surgery, commonly resulting in upper limb functional, esthetic, and psychological impairment. The necessity to improve the efficacy of conventional treatments and the promising effect of extracorporeal shock wave therapy (ESWT) on lymphangiogenesis in vitro and animal models, has prompted studies involving women affected by breast cancer-related lymphedema. Since intervention modalities and treatment protocols used are different, a review is necessary to verify the effectiveness of ESWT, evaluating the quality of existing studies and the eventual need for further research. Data were obtained from PubMed, Scopus, Google Scholar, Cochrane Library and PEDro, including articles published until January 2019. Five studies met the inclusion criteria. Evident heterogeneity emerged among selected studies permitting only a purely descriptive analysis of their data and strongly limiting their comparison. When compared to other treatment modalities, ESWT showed a significant effect on measured outcomes. It is clear that further high quality research is necessary to assert with confidence the effects and possible superiority of ESWT over other conservative therapies in the management of breast cancer-related lymphedema.

Research paper thumbnail of A Wearable System Composed of FBG-Based Soft Sensors for Trunk Compensatory Movements Detection in Post-Stroke Hemiplegic Patients

Sensors, 2022

In this study, a novel wearable system for the identification of compensatory trunk movements (CT... more In this study, a novel wearable system for the identification of compensatory trunk movements (CTMs) in post-stroke hemiplegic patients is presented. The device is composed of seven soft sensing elements (SSEs) based on fiber Bragg grating (FBG) technology. Each SSE consists of a single FBG encapsulated into a flexible matrix to enhance the sensor’s robustness and improve its compliance with the human body. The FBG’s small size, light weight, multiplexing capability, and biocompatibility make the proposed wearable system suitable for multi-point measurements without any movement restriction. Firstly, its manufacturing process is presented, together with the SSEs’ mechanical characterization to strain. Results of the metrological characterization showed a linear response of each SSE in the operating range. Then, the feasibility assessment of the proposed system is described. In particular, the device’s capability of detecting CTMs was assessed on 10 healthy volunteers and eight hemip...

Research paper thumbnail of Robotic hand treatment of patients affected by chronic stroke: a monocentric longitudinal pilot study

Journal of biological regulators and homeostatic agents, 2020

Few studies investigated the effects of a robotic treatment in hand motor recovery after stroke. ... more Few studies investigated the effects of a robotic treatment in hand motor recovery after stroke. Aim of the present study was to evaluate the efficacy of treatment by means of Gloreha Sinfonia® robotic glove in hand motor recovery of a chronic stroke sample of patients with different impairment severity. Thirteen chronic stroke subjects were assigned to either active-assisted robotic treatment or passive robotic treatment according to their ability to actively extend wrist for at least 20 degrees. All subjects underwent 20 sessions of treatment with Gloreha Sinfonia® and were evaluated before (T0), after treatment (T1) and after one month (T2) with clinical scales testing motor performance [Motor Power (MP); Fugl Meyer Upper-Extremity (FMUE)] and spasticity [Modified Ashworth Scale (MAS)]. Both groups showed significant motor recovery and spasticity reduction. Further randomized controlled trials with larger samples are needed to confirm our results.

Research paper thumbnail of Perceptive rehabilitation improves postural control in patients with Parkinson’s disease: a single-blind, randomized controlled trial

Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson ... more Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson Disease reporting promising preliminary results for postural balance and pain symptoms. To date, no randomized controlled trial was carried out to compare the effects of perceptive rehabilitation and conventional treatment in patients with Parkinson Disease. AIM: To evaluate whether a perceptive rehabilitation treatment could be more effective than a conventional physical therapy program in improving postural control and gait pattern in patients with Parkinson Disease. DESIGN: Single blind, randomized controlled trial. SETTING: Department of Physical and Rehabilitation Medicine of a University Hospital. POPULATION: Twenty outpatients affected by idiopathic Parkinson Disease at Hoehn and Yahr stage 64 3. METHODS: Recruited patients were divided into two groups: the first one underwent individual treatment with Surfaces for Perceptive Rehabilitation (Su-Per), consisting of rigid wood surfaces supporting deformable latex cones of various dimensions, and the second one received conventional group physical therapy treatment. Each patient underwent a training program consisting of ten, 45-minute sessions, three days a week for 4 consecutive weeks. Each subject was evaluated before treatment, immediately after treatment and at one month of follow-up, by an optoelectronic stereophotogrammetric system for gait and posture analysis, and by a computerized platform for stabilometric assessment. RESULTS: Kyphosis angle decreased after ten sessions of perceptive rehabilitation, thus showing a substantial difference with respect to the control group. No significant differences were found as for gait parameters (cadence, gait speed and stride length) within Su-Per group and between groups. Parameters of static and dynamic evaluation on stabilometric platform failed to demonstrate any statistically relevant difference both within-groups and between-groups. CONCLUSIONS: Perceptive training may help patients affected by Parkinson Disease into restoring a correct midline perception and, in turn, to improve postural control. CLINICAL REHABILITATION IMPACT: Perceptive surfaces represent an alternative to conventional rehabilitation of postural disorders in Parkinson Disease. Further studies are needed to determine if the association of perceptive treatment and active motor training would be useful in improving also gait dexterity

Research paper thumbnail of Validation and Assessment of a Posture Measurement System with Magneto-Inertial Measurement Units

Sensors, 2021

Inappropriate posture and the presence of spinal disorders require specific monitoring systems. I... more Inappropriate posture and the presence of spinal disorders require specific monitoring systems. In clinical settings, posture evaluation is commonly performed with visual observation, electrogoniometers or motion capture systems (MoCaps). Developing a measurement system that can be easily used also in non-structured environments would be highly beneficial for accurate posture monitoring. This work proposes a system based on three magneto-inertial measurement units (MIMU), placed on the backs of seventeen volunteers on the T3, T12 and S1 vertebrae. The reference system used for validation is a stereophotogrammetric motion capture system. The volunteers performed forward bending and sit-to-stand tests. The measured variables for identifying the posture were the kyphosis and the lordosis angles, as well as the range of movement (ROM) of the body segments. The comparison between MIMU and MoCap provided a maximum RMSE of 5.6° for the kyphosis and the lordosis angles. The average lumbo-pe...

Research paper thumbnail of Concurrent validity and inter trial reliability of a single inertial measurement unit for spatial-temporal gait parameter analysis in patients with recent total hip or total knee arthroplasty

Gait & Posture, 2020

Background: Osteoarthritis (OA) is one of the main causes of disability and its frequent hip and ... more Background: Osteoarthritis (OA) is one of the main causes of disability and its frequent hip and knee joint localization requires surgical joint replacement treatment. Patients after total hip (THA) or knee (TKA) arthroplasty often show gait abnormalities, whose comprehension is crucial in order to plan an appropriate rehabilitative treatment. Wearable sensor devices can be a valid tool for gait assessment in clinical practice, being relatively inexpensive and easy to use. Research question: Does the use of crutches influence the ability of a single inertial measurement unit (IMU), placed on the lower trunk, to correctly record the spatial-temporal gait parameters in patients after recent THA or TKA? Methods: 20 patients walking with crutches after recent THA or TKA and 10 healthy subjects were recruited. Each participant was recorded simultaneously with an IMU and with an optoelectronic motion capture system during 5 consecutive walking tests. Results: Intraclass correlation index of spatial-temporal parameters recorded with the IMU showed moderate to excellent reliability results both for healthy subjects (ICC range 0.626-0.897) and for patients (ICC range 0.596-0.951). In terms of concurrent validity, Pearson's r coefficient of healthy subjects, showed strong to very strong levels of correlations for some spatial-temporal parameters (speed, mean cadence, left and right stride length and stride duration) (r range 0.646-0.977) and very week to moderately week levels of correlation for gait cycle phases (swing, stance, single support and double support) (r range 0.390-0.633). Patients' data analysis showed similar results for general spatial-temporal parameters (r range 0.704-0.986) and slightly lower values for gait cycle phases (r range 0.077-0.464). Significance: We can consider the single IMU as a reliable tool for the detection of some spatial-temporal gait parameters. Crutches seem to interfere with the detection of the gait cycle phases.

Research paper thumbnail of A Triple Application of Kinesio Taping Supports Rehabilitation Program for Rotator Cuff Tendinopathy: a Randomized Controlled Trial

Ortopedia Traumatologia Rehabilitacja, 2018

Background. Rotator cuff tendinopathy (RoCT) is a common pathology among adults. Kinesio-taping (... more Background. Rotator cuff tendinopathy (RoCT) is a common pathology among adults. Kinesio-taping (KT) represents a possible rehabilitative treatment. The aim of the present study is to investigate the efficacy of a combination of three different applications of KT combined with a standardized protocol of rehabilitative exercises in reducing pain and in functional recovery in patients affected by RoCT. Materials and methods. 21 patients were enrolled in a real group (RG) and 19 in a sham group (SG). RG received a real KT application and SG received a sham KT application. Both groups received the same rehabilitative protocol. A Numeric Rating Scale (NRS) for shoulder pain, Medical Research Council (MRC) Scales for shoulder strength assessment and Costant Murley Score (CMS) were administered before (T0) and at the end of treatment (T1). Results. Within-group analysis for RG at T1 showed significant improvement in: NRS at-rest (p=0.002), during-movement (p<0.001); CMS (p<0.001); MR...

Research paper thumbnail of The efficacy and safety of using CartiJoint Forte (a combination of glucosamine hydrochloride, chondroitin sulfate and bio-curcumin) with exercise in the treatment of knee osteoarthritis: a randomized, double blind, placebo-controlled study

European journal of physical and rehabilitation medicine, Jan 3, 2016

Knee osteoarthritis (OA) conservative treatment aims to delay cartilage degeneration; chondroprot... more Knee osteoarthritis (OA) conservative treatment aims to delay cartilage degeneration; chondroprotectives represent one approach. A commercially available dietary supplement, CartiJoint Forte, based on glucosamine hydrochloride (GH), chondroitin sulfate (CS) and Bio-Curcumin BCM-95®, was used in this trial. To assess efficacy and safety of CartiJoint Forte combined with physical therapy in treating subjects with knee OA. A multicenter, prospective, randomized, double blind, placebo-controlled clinical trial. Outpatients referred to the Rehabilitation Departments of two University Hospitals. Fifty-three patients were randomly assigned to an experimental group (N=26) or a control group (N=27). Experimental subjects received two tablets of CartiJoint Forte each day for 8 weeks, while those in the control group were provided with a placebo. Three subjects dropped out during the course of the study. The two groups both received 20 sessions of physical therapy during the course of the tria...

Research paper thumbnail of Evaluation of optoelectronic Plethysmography accuracy and precision in recording displacements during quiet breathing simulation

2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2015

Opto-electronic Plethysmography (OEP) is a motion analysis system used to measure chest wall kine... more Opto-electronic Plethysmography (OEP) is a motion analysis system used to measure chest wall kinematics and to indirectly evaluate respiratory volumes during breathing. Its working principle is based on the computation of marker displacements placed on the chest wall. This work aims at evaluating the accuracy and precision of OEP in measuring displacement in the range of human chest wall displacement during quiet breathing. OEP performances were investigated by the use of a fully programmable chest wall simulator (CWS). CWS was programmed to move 10 times its eight shafts in the range of physiological displacement (i.e., between 1 mm and 8 mm) at three different frequencies (i.e., 0.17 Hz, 0.25 Hz, 0.33 Hz). Experiments were performed with the aim to: (i) evaluate OEP accuracy and precision error in recording displacement in the overall calibrated volume and in three sub-volumes, (ii) evaluate the OEP volume measurement accuracy due to the measurement accuracy of linear displacements. OEP showed an accuracy better than 0.08 mm in all trials, considering the whole 2m3 calibrated volume. The mean measurement discrepancy was 0.017 mm. The precision error, expressed as the ratio between measurement uncertainty and the recorded displacement by OEP, was always lower than 0.55%. Volume overestimation due to OEP linear measurement accuracy was always <; 12 mL (<; 3.2% of total volume), considering all settings.

Research paper thumbnail of Optoelectronic plethysmography to evaluate the effect of posture on breathing kinematics in spinal cord injury: a cross sectional study

European journal of physical and rehabilitation medicine, Jan 22, 2015

Spinal cord injured patients often suffer from respiratory muscles impairment. Spirometry studies... more Spinal cord injured patients often suffer from respiratory muscles impairment. Spirometry studies showed that in supine position Vital Capacity increases in such patients since diaphragm increases its inspiratory excursion. To our opinion, however, respiratory kinematics in spinal cord injured patients is disadvantaged in supine position. To evaluate the effect of posture (sitting and supine) on respiratory kinematics in chronic spinal cord injured patients using optoelectronic plethysmography. Cross-sectional study. Outpatients referring to the Movement Analysis Laboratory of a Physical and Rehabilitation Medicine Unit. Twenty chronic spinal cord injured patients (9 tetraplegics, with lesional level ranging from C3 to C7 and 11 paraplegics with lesional level ranging from T1 to T8) and twenty healthy subjects matched for gender, age and smoking habits. All subjects underwent optoelectronic evaluation in sitting and supine position during quiet breathing and hyperventilation. Additi...

Research paper thumbnail of Effectiveness And Feasibility Of A Home-Based Pulmonary Rehabilitation Programme In Postsurgical Lung Cancer Patients

A107. ASSESSMENT, EXERCISE TRAINING AND OUTCOMES, 2012

Research paper thumbnail of Disfunzione respiratoria dei pazienti con mielolesione: dati preliminari della valutazione con pletismografia optoelettronica

Research paper thumbnail of Optoelectronic Plethysmography in Clinical Practice and Research: A Review

Respiration; international review of thoracic diseases, 2017

Optoelectronic plethysmography (OEP) is a non-invasive motion capture method to measure chest wal... more Optoelectronic plethysmography (OEP) is a non-invasive motion capture method to measure chest wall movements and estimate lung volumes. To provide an overview of the clinical findings and research applications of OEP in the assessment of breathing mechanics across populations of healthy and diseased individuals. A bibliographic research was performed with the terms "opto-electronic plethysmography," "optoelectronic plethysmography," and "optoelectronic plethysmograph" in 50 digital library and bibliographic search databases resulting in the selection of 170 studies. OEP has been extensively employed in studies looking at chest wall kinematics and volume changes in chest wall compartments in healthy subjects in relation to age, gender, weight, posture, and different physiological conditions. In infants, OEP has been demonstrated to be a tool to assess disease severity and the response to pharmacological interventions. In chronic obstructive pulmonary dis...

Research paper thumbnail of Perceptive rehabilitation and trunk posture alignment in patients with Parkinson disease: a single blind randomized controlled trial

European journal of physical and rehabilitation medicine, 2016

Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson ... more Recent studies aimed to evaluate the potential effects of perceptive rehabilitation in Parkinson Disease reporting promising preliminary results for postural balance and pain symptoms. To date, no randomized controlled trial was carried out to compare the effects of perceptive rehabilitation and conventional treatment in patients with Parkinson Disease. To evaluate whether a perceptive rehabilitation treatment could be more effective than a conventional physical therapy program in improving postural control and gait pattern in patients with Parkinson Disease. Single blind, randomized controlled trial. Department of Physical and Rehabilitation Medicine of a University Hospital. Twenty outpatients affected by idiopathic Parkinson Disease at Hoehn and Yahr stage ≤3. Recruited patients were divided into two groups: the first one underwent individual treatment with Surfaces for Perceptive Rehabilitation (Su-Per), consisting of rigid wood surfaces supporting deformable latex cones of vari...