Nguyen Huu Nam - Academia.edu (original) (raw)

Papers by Nguyen Huu Nam

Research paper thumbnail of Improvement of Inverter Efficiency of Three-phase Induction Motor Control System by Space Vector Pulse-width Modulation Method

2018 10th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT), 2018

The algorithms of space vector pulse-width modulation (SVPWM) with the use of additional referenc... more The algorithms of space vector pulse-width modulation (SVPWM) with the use of additional reference vectors are proposed in this article. The proposed algorithms increase the efficiency of the frequency converter, which will eliminate the through currents in the voltage source inverter (VSI) and reduce amount of calculation in the microcontroller. In this paper the simulation model of the induction motor (IM) with SVPWM control constructed in MATLAB is studies. The results of simulation modeling of the proposed algorithms are presented using different trajectories of the voltage space vector. Comparative analysis of the results is provided based on the type of trajectories and on the number of voltage space vectors being generated for the fluctuations speed, torque, and current of the IM's stator. Result analysis showed that the proposed algorithms using additional reference vectors, not only eliminate the through currents in a three-phase VSI, but also reduce the variations in fluctuations speed, motor torque and stator current, and improve the speed of the electric drive.

Research paper thumbnail of Information Bases of Learning Modeling on the Example of a Double Fed Induction Generator

2018 IV International Conference on Information Technologies in Engineering Education (Inforino), 2018

Doubly-fed induction generators (DFIG) is designed to generate the constant value amplitude and f... more Doubly-fed induction generators (DFIG) is designed to generate the constant value amplitude and frequency of their output voltages, when frequency rotor is variable. The purpose of paper is present two structures model of DFIG-DFIG with shunt converters and DFIG with series converters. Create model and computer simulation results of DFIG in program Orcad for mode generator machine. The information of results can use for education and research activities.

Research paper thumbnail of Computer Simulation and Analysis of A Doubly Fed Induction Generator with A One Side Directly Connected to The Grid

2020 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT), 2020

Doubly fed induction generator (DFIG) is one of the most complex electrical structures for a powe... more Doubly fed induction generator (DFIG) is one of the most complex electrical structures for a power generating system (such as wind turbine and small hydro power). This paper proposes theory calculations, computer simulation and analysis structure of a DFIG with only one side connected to the grid. The stator of wound rotor induction generator (WRIG) is connected directly to the grid, and the rotor is controlled by a converter connected to an ideal battery. The theory calculation results provide the fundamental information for the initial stages of engineering design both in term of separate components (electrical machine, electronic converter) as well as the whole entire generating system. These properties and calculations determine the composition, technical implementation of the components in the system and the interaction between them. The theory and computer simulation results of a 160 kW WRIG system is also presented to prove the feasibility of the proposed system and method.

Research paper thumbnail of Modeling, Algorithm Control And Simulation Of Variable-Speed Doubly-Fed Induction Generator In Grid Connected Operation

2019 26th International Workshop on Electric Drives: Improvement in Efficiency of Electric Drives (IWED), 2019

The paper presents the modeling, computer simulation’s results of a grid connected to a doubly fe... more The paper presents the modeling, computer simulation’s results of a grid connected to a doubly fed induction generator (DFIG) at variable speed (higher, lower and synchronous speed) and give to the grid only active power. The stator windings machine is directly connected to the grid, the rotor winding machine is connected to the grid via slip-rings to a three-phase converter and made in the form of two back-to-back inverter and DC-link. The problems of synthesis of control systems that implement the principle of vector control are considered. A model of these control systems in the program MATLAB/Simulink is created. The models developed and results obtained provide information and method control for the development of DFIG generating systems.

Research paper thumbnail of Algorithmic Structure of Wind Turbines System based on an Induction Machine Directly Connected to the Grid

MATEC Web of Conferences

One of the relatively simple (comparatively cheap) and promising solutions of the wind power plan... more One of the relatively simple (comparatively cheap) and promising solutions of the wind power plant - the wind turbine system (WTS) with variable speed on the shaft of the wind wheel - is to execute it on the basic of an induction machine - IM. Today, the problem of self-excited induction machine is solved in two ways - by using either capacitors, or electronic converters. As a generating system (based on IM), several WTS are often used, working parallel or directly connected to the grid. For induction machine: squirrel-cage induction generator (SCIG) and doubly-fed induction generator (DFIG) are used, several possible types of them are systematized, evaluated and compared on functional features and properties. Based on computer simulations, the ability of DFIG with back to back converters (in the form of two serially connected 2 level voltage source converters - converter-1 and converter-2) is determined in the rotor circuit at a variable speed of the drive shaft (in modes sub-synch...

Research paper thumbnail of Имитационная модель асинхронизированного синхронного генератора при автономной работе

Research paper thumbnail of ВЕСТИ ВЫСШИХ УЧЕБНЫХ ЗАВЕДЕНИЙ ЧЕРНОЗЕМЬЯ

Research paper thumbnail of Автономная система электроснабжения на основе асинхронизированного синхронного генератора

Research paper thumbnail of ИССЛЕДОВАНИЕ ЭФФЕКТИВНОСТИ ИСПОЛЬЗОВАНИЯ ПРОМЕЖУТОЧНОГО ВЫСОКОЧАСТОТНОГО ПРЕОБРАЗОВАНИЯ ПРИ ПОСТРОЕНИИ СТАТИЧЕСКИХ ПРЕОБРАЗОВАТЕЛЕЙ   И СИСТЕМ НА ИХ ОСНОВЕ

Research paper thumbnail of Improvement of Inverter Efficiency of Three-phase Induction Motor Control System by Space Vector Pulse-width Modulation Method

2018 10th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT), 2018

The algorithms of space vector pulse-width modulation (SVPWM) with the use of additional referenc... more The algorithms of space vector pulse-width modulation (SVPWM) with the use of additional reference vectors are proposed in this article. The proposed algorithms increase the efficiency of the frequency converter, which will eliminate the through currents in the voltage source inverter (VSI) and reduce amount of calculation in the microcontroller. In this paper the simulation model of the induction motor (IM) with SVPWM control constructed in MATLAB is studies. The results of simulation modeling of the proposed algorithms are presented using different trajectories of the voltage space vector. Comparative analysis of the results is provided based on the type of trajectories and on the number of voltage space vectors being generated for the fluctuations speed, torque, and current of the IM's stator. Result analysis showed that the proposed algorithms using additional reference vectors, not only eliminate the through currents in a three-phase VSI, but also reduce the variations in fluctuations speed, motor torque and stator current, and improve the speed of the electric drive.

Research paper thumbnail of Information Bases of Learning Modeling on the Example of a Double Fed Induction Generator

2018 IV International Conference on Information Technologies in Engineering Education (Inforino), 2018

Doubly-fed induction generators (DFIG) is designed to generate the constant value amplitude and f... more Doubly-fed induction generators (DFIG) is designed to generate the constant value amplitude and frequency of their output voltages, when frequency rotor is variable. The purpose of paper is present two structures model of DFIG-DFIG with shunt converters and DFIG with series converters. Create model and computer simulation results of DFIG in program Orcad for mode generator machine. The information of results can use for education and research activities.

Research paper thumbnail of Computer Simulation and Analysis of A Doubly Fed Induction Generator with A One Side Directly Connected to The Grid

2020 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT), 2020

Doubly fed induction generator (DFIG) is one of the most complex electrical structures for a powe... more Doubly fed induction generator (DFIG) is one of the most complex electrical structures for a power generating system (such as wind turbine and small hydro power). This paper proposes theory calculations, computer simulation and analysis structure of a DFIG with only one side connected to the grid. The stator of wound rotor induction generator (WRIG) is connected directly to the grid, and the rotor is controlled by a converter connected to an ideal battery. The theory calculation results provide the fundamental information for the initial stages of engineering design both in term of separate components (electrical machine, electronic converter) as well as the whole entire generating system. These properties and calculations determine the composition, technical implementation of the components in the system and the interaction between them. The theory and computer simulation results of a 160 kW WRIG system is also presented to prove the feasibility of the proposed system and method.

Research paper thumbnail of Modeling, Algorithm Control And Simulation Of Variable-Speed Doubly-Fed Induction Generator In Grid Connected Operation

2019 26th International Workshop on Electric Drives: Improvement in Efficiency of Electric Drives (IWED), 2019

The paper presents the modeling, computer simulation’s results of a grid connected to a doubly fe... more The paper presents the modeling, computer simulation’s results of a grid connected to a doubly fed induction generator (DFIG) at variable speed (higher, lower and synchronous speed) and give to the grid only active power. The stator windings machine is directly connected to the grid, the rotor winding machine is connected to the grid via slip-rings to a three-phase converter and made in the form of two back-to-back inverter and DC-link. The problems of synthesis of control systems that implement the principle of vector control are considered. A model of these control systems in the program MATLAB/Simulink is created. The models developed and results obtained provide information and method control for the development of DFIG generating systems.

Research paper thumbnail of Algorithmic Structure of Wind Turbines System based on an Induction Machine Directly Connected to the Grid

MATEC Web of Conferences

One of the relatively simple (comparatively cheap) and promising solutions of the wind power plan... more One of the relatively simple (comparatively cheap) and promising solutions of the wind power plant - the wind turbine system (WTS) with variable speed on the shaft of the wind wheel - is to execute it on the basic of an induction machine - IM. Today, the problem of self-excited induction machine is solved in two ways - by using either capacitors, or electronic converters. As a generating system (based on IM), several WTS are often used, working parallel or directly connected to the grid. For induction machine: squirrel-cage induction generator (SCIG) and doubly-fed induction generator (DFIG) are used, several possible types of them are systematized, evaluated and compared on functional features and properties. Based on computer simulations, the ability of DFIG with back to back converters (in the form of two serially connected 2 level voltage source converters - converter-1 and converter-2) is determined in the rotor circuit at a variable speed of the drive shaft (in modes sub-synch...

Research paper thumbnail of Имитационная модель асинхронизированного синхронного генератора при автономной работе

Research paper thumbnail of ВЕСТИ ВЫСШИХ УЧЕБНЫХ ЗАВЕДЕНИЙ ЧЕРНОЗЕМЬЯ

Research paper thumbnail of Автономная система электроснабжения на основе асинхронизированного синхронного генератора

Research paper thumbnail of ИССЛЕДОВАНИЕ ЭФФЕКТИВНОСТИ ИСПОЛЬЗОВАНИЯ ПРОМЕЖУТОЧНОГО ВЫСОКОЧАСТОТНОГО ПРЕОБРАЗОВАНИЯ ПРИ ПОСТРОЕНИИ СТАТИЧЕСКИХ ПРЕОБРАЗОВАТЕЛЕЙ   И СИСТЕМ НА ИХ ОСНОВЕ