Nola Fridayanti - Academia.edu (original) (raw)

Uploads

Papers by Nola Fridayanti

Research paper thumbnail of Effect of nanoparticle geometry on sensitivity of metal nanoparticle based sensor

IOP conference series, Sep 1, 2019

Bio chemical detection using metal nanoparticles has been intensively investigated due to availab... more Bio chemical detection using metal nanoparticles has been intensively investigated due to availability of robust nanoparticle synthesis methods whether chemically or using lithographic approach. SPR based sensor employs the shift of plasmonic resonance wavelength when local surrounding medium of metal nanoparticles change even slightly. The shift of the resonance wavelength depends sensitively on geometry and size of nanoparticle. The resonance wavelength and its shift were calculated numerically using boundary element method. Here, we compare the sensitivity of gold and silver nanoparticles to sense small change in refractive index of medium. Four different geometries (spherical, ellipsoidal, cylindrical, and donut-like nanoparticles) of different size were investigated to find the highest sensor sensitivity.

Research paper thumbnail of Size and aspect ratio dependency of sensitivity of ellipsoidal metal nanoparticle based liquid sensor

IOP conference series, Oct 4, 2019

Detection of bio chemical species in a liquid is very important for research and technical purpos... more Detection of bio chemical species in a liquid is very important for research and technical purposes. In the last decade, metallic nanoparticles have been shown to be potential for such measurement. Resonance wavelength (or frequency) of free electron oscillation on metallic nanoparticle surface is very sensitive to tiny changes of its surrounding environment. Change in surrounding medium shifts the resonance wavelength with a slope determined mainly by the size and geometry of nanoparticle. We numerically optimized size and aspect ratio of silver and gold nanoparticles to obtain the highest sensing sensitivity. Here, sensitivity is defined as the slope of resonance wavelength on refractive index of liquid. We found that size, aspect ratio, and material of metal affect sensing sensitivity of metal nanoparticle based sensor significantly.

Research paper thumbnail of Aplikasi Sensor Serat Optik untuk Pengukuran Kadar Bakteri E-Coli Dalam Air

Jurnal Ilmu Fisika (JIF), Jul 15, 2019

Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi al... more Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi alat untuk mengukur kadar bakteri e-coli. Serat optik digunakan sebagai pemandu cahaya dari sumber laser dioda merah (λ=650 nm) ke fotodioda. Interaksi antara gelombang evanescent dan bakteriecoli dalam air mengakibatkan pelemahan cahaya terpandu dalam serat optik. Panjang pengupasan cladding serat optik divariasikan yaitu 1 cm, 3 cm, dan 5 cm. Konsentrasi OTS (Oktadecyl Trichloro Silane) dan panjang pengupasan serat optik mempengaruhi sensitivitas dan akurasi sensor kadar bakteri e-coli. Sensitivitas meningkat dengan semakin besarnya konsentrasi OTS dan panjang pengupasan 1 cm. Pengukuran konsentrasi bakteri e-coli oleh sensor memiliki akurasi diatas 95%. Sensitivitas tertinggi yaitu 6,25 mV/(CFU/mL) yang diperoleh dari sensor dengan konsentrasi OTS 20 mL pada panjang pengupasan 1cm.

Research paper thumbnail of Aplikasi Sensor Serat Optik untuk Pengukuran Kadar Bakteri E-Coli Dalam Air

JURNAL ILMU FISIKA | UNIVERSITAS ANDALAS, 2019

Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi al... more Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi alat untuk mengukur kadar bakteri e-coli. Serat optik digunakan sebagai pemandu cahaya dari sumber laser dioda merah (λ=650 nm) ke fotodioda. Interaksi antara gelombang evanescent dan bakterie-coli dalam air mengakibatkan pelemahan cahaya terpandu dalam serat optik. Panjang pengupasan cladding serat optik divariasikan yaitu 1 cm, 3 cm, dan 5 cm. Konsentrasi OTS (Oktadecyl Trichloro Silane) dan panjang pengupasan serat optik mempengaruhi sensitivitas dan akurasi sensor kadar bakteri e-coli. Sensitivitas meningkat dengan semakin besarnya konsentrasi OTS dan panjang pengupasan 1 cm. Pengukuran konsentrasi bakteri e-coli oleh sensor memiliki akurasi diatas 95%. Sensitivitas tertinggi yaitu 6,25 mV/(CFU/mL) yang diperoleh dari sensor dengan konsentrasi OTS 20 mL pada panjang pengupasan 1cm. Kata kunci: serat optik, gelombang evanescent, bakteri e-coli, OTS, sensitivitas, akurasi.

Research paper thumbnail of Rancang Bangun Alat Ukur Kadar Gula Darah pada Urin dengan Metode Evanescent

POSITRON, 2018

Telah dilakukan rancang bangun alat ukur kadar gula darah secara non-invasive menggunakan sampel ... more Telah dilakukan rancang bangun alat ukur kadar gula darah secara non-invasive menggunakan sampel urin dengan memanfaatkan pelemahan gelombang evanescent. Alat ukur kadar gula darah yang didesain berbasis Arduino UNO, laser dioda, serat optik, dan fotodioda. Intensitas cahaya terpandu mengalami atenuasi akibat terjadinya interaksi antara molekul glukosa dalam urin dengan gelombang evanescent pada bidang batas core-cladding serat optik. Interaksi tersebut diperkuat dengan mengupas sebagian cladding serat optik. Panjang pengupasan cladding serat optik divariasikan sebesar 1 cm, 2 cm, 3 cm, 4 cm, dan 5 cm. Penurunan intensitas cahaya terukur sebagai perubahan tegangan keluaran fotodioda yang berkorelasi dengan nilai kosentrasi glukosa. Alat ukur gula darah yang didesain dapat menampilkan hasil pengukuran kadar gula darah pada layar LCD. Hasil pengukuran menunjukkan bahwa tegangan keluaran dari sensor berkurang secara linier terhadap kadar gula darah dengan sensitivitas dan ketepatan ra...

Research paper thumbnail of Analisis Pengaruh Macrobending Serat Optik Pada Sensor Glukosa Dengan Metode Evanescent

Telah dilakukan analisis pengaruh macrobending serat optik yang telah dikupas cladding nya sepanj... more Telah dilakukan analisis pengaruh macrobending serat optik yang telah dikupas cladding nya sepanjang 1 cm pada sensor glukosa dengan memanfaatkan interaksi gelombang evanescent pada serat optik dengan molekul glukosa. Cahaya dari laser dioda dengan panjang gelombang 650 nm ditransmisikan pada serat optik multimode . Pengupasan sebagian cladding serat mengakibatkan pelemahan intensitas terukur pada detektor akibat interaksi gelombang evanescent dengan molekul glukosa dalam urine . Penurunan intensitas cahaya terukur sebagai perubahan tegangan pada fotodioda yang mengindikasikan kosentrasi glukosa. Perbedaan konsentrasi glukosa berkaitan dengan indeks bias larutan glukosa (n 2 ) yang menentukan kuat interaksi dan pelemahan gelombang evanescent . Intensitas cahaya yang sampai ke detektor meluruh secara eksponensial sebagai fungsi dari panjang pengupasan cladding serat optik. Hasil pengukuran menunjukkan bahwa tegangan keluaran dari sensor berkurang secara linear terhadap konsentrasi g...

Research paper thumbnail of Otomatisasi Rotary Sample Collector Dengan Motor Stepper Berbasis Mikrokontroller ATMEGA8535 Dan Sensor Fotodioda

Abstrak Telah dirancang suatu sistem otomasi rotary sample collector berbasis mikrokontroler ATme... more Abstrak Telah dirancang suatu sistem otomasi rotary sample collector berbasis mikrokontroler ATmega8535 untuk pengisian tabung reaksi secara otomatis. Rak tabung reaksi dirancang berbentuk piringan dari bahan karton tebal dengan diameter 22,7 cm dan massa 145 g, sedangkan poros pemutar piringan terbuat dari pipa PVC ( polyvinyl chloride ) berdiamter 2,2 cm dan massa 49,05 g. Sistem dirancang untuk mengisi dan merotasi 4 tabung reaksi. Pengisian tabung dengan zat cair dilakukan melalui kran elektrik ( electric valve ) yang katupnya dikontrol berdasarkan sinyal keluaran fotodioda. LED ( light emitting diode ) dan fotodioda berfungsi sebagai sistem sensor ketinggian zat cair dalam tabung. Ketika zat cair dalam tabung telah mencapai ketinggian tertentu, mikrokontroler mengirimkan sinyal untuk menutup katup kran, dan kemudian mengirim sinyal untuk menggerakkan motor stepper sejauh 90° (untuk 4 tabung). Ketika rotasi telah mencapai 90°, mikrokontroler mengirim sinyal untuk menghentikan mo...

Research paper thumbnail of The Effect of Laser Wavelength on Sensitivity and Accuracy of the Evanescent-Based Blood Glucose Sensor

KnE Engineering

We have developed bent fiber optic based sensors for non-invasive glucose level measurement. The ... more We have developed bent fiber optic based sensors for non-invasive glucose level measurement. The developed sensor employs the attenuation of evanescent wave in the optical fiber due to its interaction with glucose molecules in urine samples. The attenuation is proportional to the concentration of the glucose molecules. We investigated dependence of the sensitivity and the accuracy of the sensor on the wavelength of diode laser source. Three diode lasers (i.e. red laser = 650 nm, green laser = 532 nm, and violet laser = 400 nm) were used for measurements. The attenuated light in the fiber optic was detected by a photodiode and then converted to electrical signal. The interaction of evanescent wave interaction with glucose molecules was enhanced by partial removing of fiber optic cladding. The length of cladding removal was varied between 1 cm and 4 cm while bending radius was kept constant at 3.5 cm. We found that the diode laser wavelength influences the sensitivity and the accuracy of blood glucose sensor significantly. The highest sensitivity of 0.9 mV/(mg/dL) is obtained for sensor using red laser with the length of cladding removal of 2 cm. The sensitivity of the sensor using green and violet laser are 0.78 mV/(mg/dL) and 0.72 mV/(mg/dL), respectively. The highest accuracy is obtained for sensor with green laser. The accuracy of sensor with red, green, and violet laser are respectively 96.9%, 85.5%, and 84.1%.The accuracy of the developed sensor fulfills the requirement to be used by diabetic patients.

Research paper thumbnail of Effect of nanoparticle geometry on sensitivity of metal nanoparticle based sensor

IOP conference series, Sep 1, 2019

Bio chemical detection using metal nanoparticles has been intensively investigated due to availab... more Bio chemical detection using metal nanoparticles has been intensively investigated due to availability of robust nanoparticle synthesis methods whether chemically or using lithographic approach. SPR based sensor employs the shift of plasmonic resonance wavelength when local surrounding medium of metal nanoparticles change even slightly. The shift of the resonance wavelength depends sensitively on geometry and size of nanoparticle. The resonance wavelength and its shift were calculated numerically using boundary element method. Here, we compare the sensitivity of gold and silver nanoparticles to sense small change in refractive index of medium. Four different geometries (spherical, ellipsoidal, cylindrical, and donut-like nanoparticles) of different size were investigated to find the highest sensor sensitivity.

Research paper thumbnail of Size and aspect ratio dependency of sensitivity of ellipsoidal metal nanoparticle based liquid sensor

IOP conference series, Oct 4, 2019

Detection of bio chemical species in a liquid is very important for research and technical purpos... more Detection of bio chemical species in a liquid is very important for research and technical purposes. In the last decade, metallic nanoparticles have been shown to be potential for such measurement. Resonance wavelength (or frequency) of free electron oscillation on metallic nanoparticle surface is very sensitive to tiny changes of its surrounding environment. Change in surrounding medium shifts the resonance wavelength with a slope determined mainly by the size and geometry of nanoparticle. We numerically optimized size and aspect ratio of silver and gold nanoparticles to obtain the highest sensing sensitivity. Here, sensitivity is defined as the slope of resonance wavelength on refractive index of liquid. We found that size, aspect ratio, and material of metal affect sensing sensitivity of metal nanoparticle based sensor significantly.

Research paper thumbnail of Aplikasi Sensor Serat Optik untuk Pengukuran Kadar Bakteri E-Coli Dalam Air

Jurnal Ilmu Fisika (JIF), Jul 15, 2019

Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi al... more Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi alat untuk mengukur kadar bakteri e-coli. Serat optik digunakan sebagai pemandu cahaya dari sumber laser dioda merah (λ=650 nm) ke fotodioda. Interaksi antara gelombang evanescent dan bakteriecoli dalam air mengakibatkan pelemahan cahaya terpandu dalam serat optik. Panjang pengupasan cladding serat optik divariasikan yaitu 1 cm, 3 cm, dan 5 cm. Konsentrasi OTS (Oktadecyl Trichloro Silane) dan panjang pengupasan serat optik mempengaruhi sensitivitas dan akurasi sensor kadar bakteri e-coli. Sensitivitas meningkat dengan semakin besarnya konsentrasi OTS dan panjang pengupasan 1 cm. Pengukuran konsentrasi bakteri e-coli oleh sensor memiliki akurasi diatas 95%. Sensitivitas tertinggi yaitu 6,25 mV/(CFU/mL) yang diperoleh dari sensor dengan konsentrasi OTS 20 mL pada panjang pengupasan 1cm.

Research paper thumbnail of Aplikasi Sensor Serat Optik untuk Pengukuran Kadar Bakteri E-Coli Dalam Air

JURNAL ILMU FISIKA | UNIVERSITAS ANDALAS, 2019

Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi al... more Telah dilakukan fungsionalisasi sensor serat optik untuk meningkatkan sensitivitas dan akurasi alat untuk mengukur kadar bakteri e-coli. Serat optik digunakan sebagai pemandu cahaya dari sumber laser dioda merah (λ=650 nm) ke fotodioda. Interaksi antara gelombang evanescent dan bakterie-coli dalam air mengakibatkan pelemahan cahaya terpandu dalam serat optik. Panjang pengupasan cladding serat optik divariasikan yaitu 1 cm, 3 cm, dan 5 cm. Konsentrasi OTS (Oktadecyl Trichloro Silane) dan panjang pengupasan serat optik mempengaruhi sensitivitas dan akurasi sensor kadar bakteri e-coli. Sensitivitas meningkat dengan semakin besarnya konsentrasi OTS dan panjang pengupasan 1 cm. Pengukuran konsentrasi bakteri e-coli oleh sensor memiliki akurasi diatas 95%. Sensitivitas tertinggi yaitu 6,25 mV/(CFU/mL) yang diperoleh dari sensor dengan konsentrasi OTS 20 mL pada panjang pengupasan 1cm. Kata kunci: serat optik, gelombang evanescent, bakteri e-coli, OTS, sensitivitas, akurasi.

Research paper thumbnail of Rancang Bangun Alat Ukur Kadar Gula Darah pada Urin dengan Metode Evanescent

POSITRON, 2018

Telah dilakukan rancang bangun alat ukur kadar gula darah secara non-invasive menggunakan sampel ... more Telah dilakukan rancang bangun alat ukur kadar gula darah secara non-invasive menggunakan sampel urin dengan memanfaatkan pelemahan gelombang evanescent. Alat ukur kadar gula darah yang didesain berbasis Arduino UNO, laser dioda, serat optik, dan fotodioda. Intensitas cahaya terpandu mengalami atenuasi akibat terjadinya interaksi antara molekul glukosa dalam urin dengan gelombang evanescent pada bidang batas core-cladding serat optik. Interaksi tersebut diperkuat dengan mengupas sebagian cladding serat optik. Panjang pengupasan cladding serat optik divariasikan sebesar 1 cm, 2 cm, 3 cm, 4 cm, dan 5 cm. Penurunan intensitas cahaya terukur sebagai perubahan tegangan keluaran fotodioda yang berkorelasi dengan nilai kosentrasi glukosa. Alat ukur gula darah yang didesain dapat menampilkan hasil pengukuran kadar gula darah pada layar LCD. Hasil pengukuran menunjukkan bahwa tegangan keluaran dari sensor berkurang secara linier terhadap kadar gula darah dengan sensitivitas dan ketepatan ra...

Research paper thumbnail of Analisis Pengaruh Macrobending Serat Optik Pada Sensor Glukosa Dengan Metode Evanescent

Telah dilakukan analisis pengaruh macrobending serat optik yang telah dikupas cladding nya sepanj... more Telah dilakukan analisis pengaruh macrobending serat optik yang telah dikupas cladding nya sepanjang 1 cm pada sensor glukosa dengan memanfaatkan interaksi gelombang evanescent pada serat optik dengan molekul glukosa. Cahaya dari laser dioda dengan panjang gelombang 650 nm ditransmisikan pada serat optik multimode . Pengupasan sebagian cladding serat mengakibatkan pelemahan intensitas terukur pada detektor akibat interaksi gelombang evanescent dengan molekul glukosa dalam urine . Penurunan intensitas cahaya terukur sebagai perubahan tegangan pada fotodioda yang mengindikasikan kosentrasi glukosa. Perbedaan konsentrasi glukosa berkaitan dengan indeks bias larutan glukosa (n 2 ) yang menentukan kuat interaksi dan pelemahan gelombang evanescent . Intensitas cahaya yang sampai ke detektor meluruh secara eksponensial sebagai fungsi dari panjang pengupasan cladding serat optik. Hasil pengukuran menunjukkan bahwa tegangan keluaran dari sensor berkurang secara linear terhadap konsentrasi g...

Research paper thumbnail of Otomatisasi Rotary Sample Collector Dengan Motor Stepper Berbasis Mikrokontroller ATMEGA8535 Dan Sensor Fotodioda

Abstrak Telah dirancang suatu sistem otomasi rotary sample collector berbasis mikrokontroler ATme... more Abstrak Telah dirancang suatu sistem otomasi rotary sample collector berbasis mikrokontroler ATmega8535 untuk pengisian tabung reaksi secara otomatis. Rak tabung reaksi dirancang berbentuk piringan dari bahan karton tebal dengan diameter 22,7 cm dan massa 145 g, sedangkan poros pemutar piringan terbuat dari pipa PVC ( polyvinyl chloride ) berdiamter 2,2 cm dan massa 49,05 g. Sistem dirancang untuk mengisi dan merotasi 4 tabung reaksi. Pengisian tabung dengan zat cair dilakukan melalui kran elektrik ( electric valve ) yang katupnya dikontrol berdasarkan sinyal keluaran fotodioda. LED ( light emitting diode ) dan fotodioda berfungsi sebagai sistem sensor ketinggian zat cair dalam tabung. Ketika zat cair dalam tabung telah mencapai ketinggian tertentu, mikrokontroler mengirimkan sinyal untuk menutup katup kran, dan kemudian mengirim sinyal untuk menggerakkan motor stepper sejauh 90° (untuk 4 tabung). Ketika rotasi telah mencapai 90°, mikrokontroler mengirim sinyal untuk menghentikan mo...

Research paper thumbnail of The Effect of Laser Wavelength on Sensitivity and Accuracy of the Evanescent-Based Blood Glucose Sensor

KnE Engineering

We have developed bent fiber optic based sensors for non-invasive glucose level measurement. The ... more We have developed bent fiber optic based sensors for non-invasive glucose level measurement. The developed sensor employs the attenuation of evanescent wave in the optical fiber due to its interaction with glucose molecules in urine samples. The attenuation is proportional to the concentration of the glucose molecules. We investigated dependence of the sensitivity and the accuracy of the sensor on the wavelength of diode laser source. Three diode lasers (i.e. red laser = 650 nm, green laser = 532 nm, and violet laser = 400 nm) were used for measurements. The attenuated light in the fiber optic was detected by a photodiode and then converted to electrical signal. The interaction of evanescent wave interaction with glucose molecules was enhanced by partial removing of fiber optic cladding. The length of cladding removal was varied between 1 cm and 4 cm while bending radius was kept constant at 3.5 cm. We found that the diode laser wavelength influences the sensitivity and the accuracy of blood glucose sensor significantly. The highest sensitivity of 0.9 mV/(mg/dL) is obtained for sensor using red laser with the length of cladding removal of 2 cm. The sensitivity of the sensor using green and violet laser are 0.78 mV/(mg/dL) and 0.72 mV/(mg/dL), respectively. The highest accuracy is obtained for sensor with green laser. The accuracy of sensor with red, green, and violet laser are respectively 96.9%, 85.5%, and 84.1%.The accuracy of the developed sensor fulfills the requirement to be used by diabetic patients.