Pietro Romano - Academia.edu (original) (raw)
Papers by Pietro Romano
IEEE Transactions on Industry Applications, 2016
Article CITATIONS 0 READS 8 7 authors, including: Some of the authors of this publication are als... more Article CITATIONS 0 READS 8 7 authors, including: Some of the authors of this publication are also working on these related projects: Simultaneous measurements of space charges and partial discharges View project R. Candela Prysmian Group
IEEE Transactions on Industry Applications, 2015
In this paper the performances of rainfall energy harvesting by means of piezoelectric transducer... more In this paper the performances of rainfall energy harvesting by means of piezoelectric transducers is presented. Diverse studies agree on the level of suitable generated voltage on the electrodes of a piezoelectric transducer subjected to rainfall, but a complete characterization on the supplied power is still missing. This work, in order to limit optimistic forecasts, takes into account the behavior of the transducers subjected to real and also artificial rainfall, condition that has shown promising behavior in laboratory. In order to increase the energy harvesting and also define its limits different loads have been taken into account. Only commercial transducers have been considered: a lead zirconate titanate and polyvinylidene difluoride transducer.
1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319), 1999
2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225), 2001
The failure probability of the insulation in H V components can be studied through Partial Discha... more The failure probability of the insulation in H V components can be studied through Partial Discharge (PD) measurements to detect defects. In this paper a numerical model, previously developed by the authors for the simulation of PD activity in a spherical void embedded in epoxy resin, is implemented to a flat cavity under divergent electric field. This situation simulates very well the real working conditions encountered in the insulation of electrical machines. The model is developed taking into account all the geometric and electrical parameters, indeed it is carried out a fine examination on physical parameters playing a fundamental role on the PD phenomenon. In particular, a more accurate formulation of the work function and a Finite Elements Analysis (FEA) of electric field inside the cavity has been applied. Indeed a new approach is investigated to reproduce the uncertainty of the discharge phenomenon. A probability fimction distribution, obtained by Weibull analysis, gains the best results. In order to obtain the best fitting o f the model output to the experimental PD data, a strong procedure based on an heuristic algorithm has been performed. This algorithm detects the minimum of a quality function that evaluates the distance between the PD patterns of the numerical model and of the experimental data. After a description of the numerical model adopted, a comparison between the experimental and the simulated data are presented together with comments and remarks.
Wiley Encyclopedia of Management, 2015
Wiley Encyclopedia of Management, 2015
Wiley Encyclopedia of Management, 2015
2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225), 2001
Il nuovo metodo di riconoscimento proposto, sfruttando le conoscenze acquisite nel campo dell'ela... more Il nuovo metodo di riconoscimento proposto, sfruttando le conoscenze acquisite nel campo dell'elaborazione di immagini, si basa sull'applicazione della decomposizione wavelet multirisoluzione (MWD) per l'identificazione di fenomeni di scarica sovrapposti.
This work presents a preliminary study on the implementation of a new system for power output max... more This work presents a preliminary study on the implementation of a new system for power output maximization of photovoltaic generators under non-homogeneous conditions. The study evaluates the performance of an efficient switching matrix and the relevant automatic reconfiguration control algorithms. The switching matrix is installed between the PV generator and the inverter, allowing a large number of possible module configurations. PV generator, switching matrix and the intelligent controller have been simulated in Simulink. The proposed reconfiguration system improved the energy extracted by the PV generator under non-uniform solar irradiation conditions. Short calculation times of the proposed control algorithms allow its use in real time applications even where a higher number of PV modules is required.
2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225), 2001
The problem of how 50Hz power supply voltage distortions affect PD activity and the lifetime of e... more The problem of how 50Hz power supply voltage distortions affect PD activity and the lifetime of epoxy resin insulation systems, is addressed in this paper. In this aim, harmonics up to the 5'h were summed up to the voltage fundamental component changing the waveform from the sinusoidal into its peaked or flattened resulting shape. In a previous paper, life tests were performed using a sphere-plane electrode configuration, now the experimental research has been carried out in progress, and an analysis of the PD aging phenomena was carried out in both sinusoidal and non-sinusoidal life tests by a digital PD system. A good agreement has been found between the physical phenomena involved during -the aging and the obtained new related lifetimes. Finally, a life model is proposed to establish a functional relationship between the shape characteristics of the applied voltage and the failure times, thus providing a useful tool to evaluate the epoxy life changes due to the presence of voltage harmonics with respect to the sinusoidal supply.
IEEE Transactions on Industry Applications, 2016
Article CITATIONS 0 READS 8 7 authors, including: Some of the authors of this publication are als... more Article CITATIONS 0 READS 8 7 authors, including: Some of the authors of this publication are also working on these related projects: Simultaneous measurements of space charges and partial discharges View project R. Candela Prysmian Group
IEEE Transactions on Industry Applications, 2015
In this paper the performances of rainfall energy harvesting by means of piezoelectric transducer... more In this paper the performances of rainfall energy harvesting by means of piezoelectric transducers is presented. Diverse studies agree on the level of suitable generated voltage on the electrodes of a piezoelectric transducer subjected to rainfall, but a complete characterization on the supplied power is still missing. This work, in order to limit optimistic forecasts, takes into account the behavior of the transducers subjected to real and also artificial rainfall, condition that has shown promising behavior in laboratory. In order to increase the energy harvesting and also define its limits different loads have been taken into account. Only commercial transducers have been considered: a lead zirconate titanate and polyvinylidene difluoride transducer.
1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319), 1999
2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225), 2001
The failure probability of the insulation in H V components can be studied through Partial Discha... more The failure probability of the insulation in H V components can be studied through Partial Discharge (PD) measurements to detect defects. In this paper a numerical model, previously developed by the authors for the simulation of PD activity in a spherical void embedded in epoxy resin, is implemented to a flat cavity under divergent electric field. This situation simulates very well the real working conditions encountered in the insulation of electrical machines. The model is developed taking into account all the geometric and electrical parameters, indeed it is carried out a fine examination on physical parameters playing a fundamental role on the PD phenomenon. In particular, a more accurate formulation of the work function and a Finite Elements Analysis (FEA) of electric field inside the cavity has been applied. Indeed a new approach is investigated to reproduce the uncertainty of the discharge phenomenon. A probability fimction distribution, obtained by Weibull analysis, gains the best results. In order to obtain the best fitting o f the model output to the experimental PD data, a strong procedure based on an heuristic algorithm has been performed. This algorithm detects the minimum of a quality function that evaluates the distance between the PD patterns of the numerical model and of the experimental data. After a description of the numerical model adopted, a comparison between the experimental and the simulated data are presented together with comments and remarks.
Wiley Encyclopedia of Management, 2015
Wiley Encyclopedia of Management, 2015
Wiley Encyclopedia of Management, 2015
2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225), 2001
Il nuovo metodo di riconoscimento proposto, sfruttando le conoscenze acquisite nel campo dell'ela... more Il nuovo metodo di riconoscimento proposto, sfruttando le conoscenze acquisite nel campo dell'elaborazione di immagini, si basa sull'applicazione della decomposizione wavelet multirisoluzione (MWD) per l'identificazione di fenomeni di scarica sovrapposti.
This work presents a preliminary study on the implementation of a new system for power output max... more This work presents a preliminary study on the implementation of a new system for power output maximization of photovoltaic generators under non-homogeneous conditions. The study evaluates the performance of an efficient switching matrix and the relevant automatic reconfiguration control algorithms. The switching matrix is installed between the PV generator and the inverter, allowing a large number of possible module configurations. PV generator, switching matrix and the intelligent controller have been simulated in Simulink. The proposed reconfiguration system improved the energy extracted by the PV generator under non-uniform solar irradiation conditions. Short calculation times of the proposed control algorithms allow its use in real time applications even where a higher number of PV modules is required.
2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225), 2001
The problem of how 50Hz power supply voltage distortions affect PD activity and the lifetime of e... more The problem of how 50Hz power supply voltage distortions affect PD activity and the lifetime of epoxy resin insulation systems, is addressed in this paper. In this aim, harmonics up to the 5'h were summed up to the voltage fundamental component changing the waveform from the sinusoidal into its peaked or flattened resulting shape. In a previous paper, life tests were performed using a sphere-plane electrode configuration, now the experimental research has been carried out in progress, and an analysis of the PD aging phenomena was carried out in both sinusoidal and non-sinusoidal life tests by a digital PD system. A good agreement has been found between the physical phenomena involved during -the aging and the obtained new related lifetimes. Finally, a life model is proposed to establish a functional relationship between the shape characteristics of the applied voltage and the failure times, thus providing a useful tool to evaluate the epoxy life changes due to the presence of voltage harmonics with respect to the sinusoidal supply.