Robbie Elbertse - Academia.edu (original) (raw)

Related Authors

Franz  Giessibl

Young Jae Song

Yande Que

Mark Gubrud

rami dana

rami dana

Massachusetts Institute of Technology (MIT)

Uploads

Papers by Robbie Elbertse

Research paper thumbnail of Development of a scanning tunneling microscope for variable temperature electron spin resonance

Review of Scientific Instruments

Recent advances in improving the spectroscopic energy resolution in scanning tunneling microscopy... more Recent advances in improving the spectroscopic energy resolution in scanning tunneling microscopy (STM) have been achieved by integrating electron spin resonance (ESR) with STM. Here, we demonstrate the design and performance of a homebuilt STM capable of ESR at temperatures ranging from 1 to 10 K. The STM is incorporated with a homebuilt Joule–Thomson refrigerator and a two-axis vector magnet. Our STM design allows for the deposition of atoms and molecules directly into the cold STM, eliminating the need to extract the sample for deposition. In addition, we adopt two methods to apply radio-frequency (RF) voltages to the tunnel junction: the early design of wiring to the STM tip directly and a more recent idea to use an RF antenna. Direct comparisons of ESR results measured using the two methods and simulations of electric field distribution around the tunnel junction show that, despite their different designs and capacitive coupling to the tunnel junction, there is no discernible d...

Research paper thumbnail of Development of a scanning tunneling microscope for variable temperature electron spin resonance

Review of Scientific Instruments

Recent advances in improving the spectroscopic energy resolution in scanning tunneling microscopy... more Recent advances in improving the spectroscopic energy resolution in scanning tunneling microscopy (STM) have been achieved by integrating electron spin resonance (ESR) with STM. Here, we demonstrate the design and performance of a homebuilt STM capable of ESR at temperatures ranging from 1 to 10 K. The STM is incorporated with a homebuilt Joule–Thomson refrigerator and a two-axis vector magnet. Our STM design allows for the deposition of atoms and molecules directly into the cold STM, eliminating the need to extract the sample for deposition. In addition, we adopt two methods to apply radio-frequency (RF) voltages to the tunnel junction: the early design of wiring to the STM tip directly and a more recent idea to use an RF antenna. Direct comparisons of ESR results measured using the two methods and simulations of electric field distribution around the tunnel junction show that, despite their different designs and capacitive coupling to the tunnel junction, there is no discernible d...

Log In