Silvina Mariana González - Academia.edu (original) (raw)

Papers by Silvina Mariana González

Research paper thumbnail of In-Situ Determination of the Wall’s Thermal Properties for Energy Retrofit in a Colonial Heritage Building: The Cabildo of Salta, Argentina

The energy retrofit of historic buildings requires identifying the materials and thermal properti... more The energy retrofit of historic buildings requires identifying the materials and thermal properties of the building fabric. This information is essential for building energy simulation, conservation, and restoration, but, unfortunately, it is usually scarce or even non-existent in documentary sources or historical studies. This paper presents the non-destructive thermal characterization of the façade walls of the historic Cabildo of Salta, Argentina. The interdisciplinary methodology includes preliminary historical and morphological studies, identification of the masonry patterns through infrared thermography, characterization of the material thermal properties through non-destructive measurements and novel dynamical computational methods, and the integrated analysis of the results based on a cross-referencing of masonry pattern, materials, and historical data. The obtained results provide scientific support for decision making in future energy retrofit strategies and building resto...

Research paper thumbnail of Comparison of four in-situ methods for the determination of walls thermal resistance in free-running buildings with alternating heat flux in different seasons

Construction and Building Materials, Nov 1, 2019

h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied... more h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied. Free-running buildings with alternating heat flux were analyzed. Data included simulations and experimental data of four wall-types. Effect of the measuring conditions on convergence was studied. The Pentaur dynamic method produces the most accurate results in all cases.

Research paper thumbnail of Study of the energy consumption of a massive free-running building in the Argentinean northwest through monitoring and thermal simulation

Energy and Buildings, Apr 1, 2012

The investigation presented in this paper has three main objectives. The first one is to study, t... more The investigation presented in this paper has three main objectives. The first one is to study, through a case study, if it is possible to acceptably predict the energy consumption of a massive residential freerunning building, when the exact behavior of the occupants is unknown or actual indoor conditions are not monitored, assuming standard use and occupation schedules, for the dry climate of the Argentinean Northwest. The second objective of the paper is to detect the possible causes of differences between actual and predicted energy consumption through an exhaustive thermal monitoring and occupant's behavior, in order to obtain an improved model of the building giving more accurate predictions of the energy consumption. The third objective is to analyze the effect on the annual energy consumption of changing the massive envelope by a lightweight one. The comparison of real and simulated consumptions under comfort conditions defined by ASHRAE Standard 55 shows that simulations overestimated the energy consumption for heating and cooling. The main causes were detected from the experimental monitoring, indicating a lower use of the air conditioning equipment than the supposed initially. Simulations were improved to consider actual use and occupation conditions. Finally, an annual simulation of the improved model performed by changing the envelope material to a lightweight one showed that energy consumption for heating was increased, while energy consumption for cooling was decreased. In an annual balance, the massive walls are preferable over lightweight ones in arid sunny climates as in the Argentinean Northwest, giving energy savings of around 25%.

Research paper thumbnail of Thermal Evaluation and Modeling of a Double-pass Solar Collector for Air Heating

Research paper thumbnail of Modelización y simulación computacional de acumuladores de calor de lecho de piedras para aplicaciones solares térmicas

Avances en Energías Renovables y Medio Ambiente - AVERMA, 2013

Research paper thumbnail of Optimización del área de colección y del flujo de aire de un colector solar de aire de doble flujo mediante simulación con SIMUSOL

Avances en Energías Renovables y Medio Ambiente - AVERMA, 2013

RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colecc... more RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colección de un colector solar de doble flujo en contracorriente previamente estudiado, teniendo en cuenta no sólo los aspectos térmicos de maximización de la eficiencia sino también aspectos económicos y de funcionamiento. El estudio se realiza para condiciones climáticas correspondientes al período invernal de la Ciudad de Salta, en base a un modelo térmico obtenido previamente mediante el software SIMUSOL y validado con datos experimentales. Los resultados obtenidos indican que es térmica y económicamente conveniente trabajar con una longitud de colección de 2.4 metros y una velocidad del aire de 4m/s, lo cual resulta en una eficiencia global del 80% y una temperatura de salida del aire de alrededor de 40ºC, la cual se considera aceptable para su utilización en calefacción de ambientes interiores residenciales de la Ciudad de Salta. Palabras clave: Colector solar, doble flujo, simulación, velocidad de aire, flujo óptimo, longitud óptima. INTRODUCCIÓN La utilización de colectores solares para calefacción de ambientes interiores es una alternativa viable para disminuir el consumo de energía convencional de los edificios. En trabajos previos se avanzó en el estudio de un colector solar de doble flujo en contracorriente. Dicho colector cuenta con un área de colección útil de 2m 2 (0.83m de ancho x 2.40m de largo). El aire proveniente del ambiente exterior ingresa por la boca de entrada ubicada en el lateral superior del colector recorriendo su primer paso entre la cubierta de policarbonato alveolar (6mm) y la placa absorbedora, y retorna en su segundo paso por debajo de la placa absorbedora (Figura 1). El colector se encuentra aislado térmicamente en los laterales y parte baja con lana de vidrio de 5cm de espesor, como así también el circuito de salida por donde circula el aire hasta llegar al ventilador. Toda la estructura del colector, la placa absorbedora, la boca de extensión, la caja del ventilador, están construidos con el mismo material de chapa galvanizada plana calibre 27. La placa absorbedora se encuentra cubierta con esmalte negro resistente a las altas temperaturas.

Research paper thumbnail of Evaluación térmica y de confort en salas del cabildo de Salta en invierno

Avances en Energías Renovables y Medio Ambiente - AVERMA, Aug 5, 2020

En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabi... more En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabildo de Salta, sede actual del Museo Histórico del Norte, con el objeto de estudiar en el futuro las tecnologías aplicables a la envolvente que permitan disminuir el consumo energético y mejorar las condiciones higrotérmicas interiores de edificios con valor patrimonial. En este tipo de edificios la rehabilitación energética debe ser respetuosa y no invasiva. Para un periodo de 15 días de invierno, se recopilaron datos de temperatura y humedad en diferentes espacios del edificio a intervalos de 15 minutos. Los locales relevados funcionan actualmente como salas de exposición del museo, oficinas administrativas y talleres de conservación o reservas del museo. Se incluyó en el análisis una evaluación de las condiciones de confort según ASHRAE-55 (Voto Medio Predicho y Porcentaje de Personas Insatisfechas), como así también las condiciones de conservación de los objetos expuestos, en un grupo de cuatro espacios destinados a salas de exposiciones.Fil: Gea Salim, Camila. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; ArgentinaFil: Hongn, Marcos Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; ArgentinaFil: González, Silvina Mariana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; ArgentinaFil: Flores Larsen, Silvana Elinor. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; Argentin

Research paper thumbnail of Evaluación térmica y de confort en salas del cabildo de Salta en invierno

En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabi... more En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabildo de Salta, sede actual del Museo Histórico del Norte, con el objeto de estudiar en el futuro las tecnologías aplicables a la envolvente que permitan disminuir el consumo energético y mejorar las condiciones higrotérmicas interiores de edificios con valor patrimonial. En este tipo de edificios la rehabilitación energética debe ser respetuosa y no invasiva. Para un periodo de 15 días de invierno, se recopilaron datos de temperatura y humedad en diferentes espacios del edificio a intervalos de 15 minutos. Los locales relevados funcionan actualmente como salas de exposición del museo, oficinas administrativas y talleres de conservación o reservas del museo. Se incluyó en el análisis una evaluación de las condiciones de confort según ASHRAE-55 (Voto Medio Predicho y Porcentaje de Personas Insatisfechas), como así también las condiciones de conservación de los objetos expuestos, en un grupo...

Research paper thumbnail of Determinación in situ de la resistencia térmica de muros en edificios históricos: métodos estacionario y dinámicos

Avances en Energías Renovables y Medio Ambiente - AVERMA, Dec 1, 2019

Research paper thumbnail of Optimización del área de colección y del flujo de aire de un colector solar de aire de doble flujo mediante simulación con SIMUSOL

Avances en Energías Renovables y Medio Ambiente - AVERMA, 2013

RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colecc... more RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colección de un colector solar de doble flujo en contracorriente previamente estudiado, teniendo en cuenta no sólo los aspectos térmicos de maximización de la eficiencia sino también aspectos económicos y de funcionamiento. El estudio se realiza para condiciones climáticas correspondientes al período invernal de la Ciudad de Salta, en base a un modelo térmico obtenido previamente mediante el software SIMUSOL y validado con datos experimentales. Los resultados obtenidos indican que es térmica y económicamente conveniente trabajar con una longitud de colección de 2.4 metros y una velocidad del aire de 4m/s, lo cual resulta en una eficiencia global del 80% y una temperatura de salida del aire de alrededor de 40ºC, la cual se considera aceptable para su utilización en calefacción de ambientes interiores residenciales de la Ciudad de Salta. Palabras clave: Colector solar, doble flujo, simulación, velocidad de aire, flujo óptimo, longitud óptima. INTRODUCCIÓN La utilización de colectores solares para calefacción de ambientes interiores es una alternativa viable para disminuir el consumo de energía convencional de los edificios. En trabajos previos se avanzó en el estudio de un colector solar de doble flujo en contracorriente. Dicho colector cuenta con un área de colección útil de 2m 2 (0.83m de ancho x 2.40m de largo). El aire proveniente del ambiente exterior ingresa por la boca de entrada ubicada en el lateral superior del colector recorriendo su primer paso entre la cubierta de policarbonato alveolar (6mm) y la placa absorbedora, y retorna en su segundo paso por debajo de la placa absorbedora (Figura 1). El colector se encuentra aislado térmicamente en los laterales y parte baja con lana de vidrio de 5cm de espesor, como así también el circuito de salida por donde circula el aire hasta llegar al ventilador. Toda la estructura del colector, la placa absorbedora, la boca de extensión, la caja del ventilador, están construidos con el mismo material de chapa galvanizada plana calibre 27. La placa absorbedora se encuentra cubierta con esmalte negro resistente a las altas temperaturas.

Research paper thumbnail of Comportamiento térmico del Cabildo de Salta en verano

Avances en Energías Renovables y Medio Ambiente, Dec 30, 2020

Research paper thumbnail of Estudio experimental de un colector solar calentador de aire de doble flujo: resultados preliminares

Research paper thumbnail of Cargas Termicas De Edificios en Estado Transitorio: Su Influencia en El Dimensionamiento De Colectores Solares De Aire

Research paper thumbnail of Análisis del comportamiento térmico de una enredadera mediante termografía infrarroja

The objective of this work is to study the thermal behaviour of a climbing plant through infrared... more The objective of this work is to study the thermal behaviour of a climbing plant through infrared thermography and the determination of its dependance on the solar irradiation. For that aim a method was developed to measure the temperature profile in the depth of the climbing plant canopy through a cuantitative analysis of thermographic images, and the temperature distribution was determined for superficial and profound canopy layers. A linear correlation was found between the differences of this temperatures with the ambient temperature and the total incident radiant energy during the hour before solar noon, for winter conditions. The scope of the method was analized and the means to improve it for future applications in the validation of thermal simulation models of the building's envelope.

Research paper thumbnail of Modelizacion numerica de un colector solar calentador de aire con matriz porosa metálica

Fil: Hernandez, Alejandro Luis. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centr... more Fil: Hernandez, Alejandro Luis. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnologico Salta. Instituto de Investigaciones En Energia No Convencional; Argentina. Universidad Nacional de Salta; Argentina

Research paper thumbnail of Ensayo de un colector solar calentador de aire de doble paso con matriz porosa para el calentamiento de edificios

Fil: Gonzalez, Silvina Mariana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centr... more Fil: Gonzalez, Silvina Mariana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnologico Conicet - Salta. Instituto de Investigaciones en Energia No Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Fisica. Instituto de Investigaciones en Energia No Convencional; Argentina

Research paper thumbnail of Comparison of four in-situ methods for the determination of walls thermal resistance in free-running buildings with alternating heat flux in different seasons

Construction and Building Materials, 2019

h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied... more h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied. Free-running buildings with alternating heat flux were analyzed. Data included simulations and experimental data of four wall-types. Effect of the measuring conditions on convergence was studied. The Pentaur dynamic method produces the most accurate results in all cases.

Research paper thumbnail of Preventive treatments for breast cancer: recent developments

Clinical and Translational Oncology, 2014

Breast cancer is a burden for western societies, and an increasing one in emerging economies, bec... more Breast cancer is a burden for western societies, and an increasing one in emerging economies, because of its high incidence and enormous psychological, social, sanitary and economic costs. However, breast cancer is a preventable disease in a significant proportion. Recent developments in the armamentarium of effective drugs for breast cancer prevention (namely exemestane and anastrozole), the new recommendation from the National Institute for Health and Care Excellence to use preventative drugs in women at high risk as well as updated Guidelines from the US Preventive Services Task Force and the American Society of Clinical Oncology should give renewed momentum to the pharmacological prevention of breast cancer. In this article we review recent major developments in the field and examine their ongoing repercussion for breast cancer prevention. As a practical example, the potential impact of preventive measures in Spain is evaluated and a course of practical actions is delineated.

Research paper thumbnail of Study of the energy consumption of a massive free-running building in the Argentinean northwest through monitoring and thermal simulation

Energy and Buildings, 2012

The investigation presented in this paper has three main objectives. The first one is to study, t... more The investigation presented in this paper has three main objectives. The first one is to study, through a case study, if it is possible to acceptably predict the energy consumption of a massive residential freerunning building, when the exact behavior of the occupants is unknown or actual indoor conditions are not monitored, assuming standard use and occupation schedules, for the dry climate of the Argentinean Northwest. The second objective of the paper is to detect the possible causes of differences between actual and predicted energy consumption through an exhaustive thermal monitoring and occupant's behavior, in order to obtain an improved model of the building giving more accurate predictions of the energy consumption. The third objective is to analyze the effect on the annual energy consumption of changing the massive envelope by a lightweight one. The comparison of real and simulated consumptions under comfort conditions defined by ASHRAE Standard 55 shows that simulations overestimated the energy consumption for heating and cooling. The main causes were detected from the experimental monitoring, indicating a lower use of the air conditioning equipment than the supposed initially. Simulations were improved to consider actual use and occupation conditions. Finally, an annual simulation of the improved model performed by changing the envelope material to a lightweight one showed that energy consumption for heating was increased, while energy consumption for cooling was decreased. In an annual balance, the massive walls are preferable over lightweight ones in arid sunny climates as in the Argentinean Northwest, giving energy savings of around 25%.

Research paper thumbnail of Modelización y Simulación Computacional De Acumuladores De Calor De Lecho De Piedras Para Aplicaciones Solares Térmicas

The aim of this paper is to analyze the influence of different parameters on the thermo-energetic... more The aim of this paper is to analyze the influence of different parameters on the thermo-energetic behaviour of a heat storage packed bed through the development of a computational tool based on the mathematical model of Schumann. Starting fromthe local energy balances, algebraic and differential equations that describe the temperature distribution inside it and the amounts of energy stored and extracted from the bed were obtained. These equations were discretized and transformed into computational algorithms with which the PETRA software was developed and the influence of rock type, bed length and the direction of rotation of the fan on the extractable energy from the accumulator were evaluated. The pressure difference along the bed was also evaluated. The results indicate that more energy can be extracted from the accumulator using an invertible rotation fan, being higher the overall efficiency of the collector-accumulator system.

Research paper thumbnail of In-Situ Determination of the Wall’s Thermal Properties for Energy Retrofit in a Colonial Heritage Building: The Cabildo of Salta, Argentina

The energy retrofit of historic buildings requires identifying the materials and thermal properti... more The energy retrofit of historic buildings requires identifying the materials and thermal properties of the building fabric. This information is essential for building energy simulation, conservation, and restoration, but, unfortunately, it is usually scarce or even non-existent in documentary sources or historical studies. This paper presents the non-destructive thermal characterization of the façade walls of the historic Cabildo of Salta, Argentina. The interdisciplinary methodology includes preliminary historical and morphological studies, identification of the masonry patterns through infrared thermography, characterization of the material thermal properties through non-destructive measurements and novel dynamical computational methods, and the integrated analysis of the results based on a cross-referencing of masonry pattern, materials, and historical data. The obtained results provide scientific support for decision making in future energy retrofit strategies and building resto...

Research paper thumbnail of Comparison of four in-situ methods for the determination of walls thermal resistance in free-running buildings with alternating heat flux in different seasons

Construction and Building Materials, Nov 1, 2019

h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied... more h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied. Free-running buildings with alternating heat flux were analyzed. Data included simulations and experimental data of four wall-types. Effect of the measuring conditions on convergence was studied. The Pentaur dynamic method produces the most accurate results in all cases.

Research paper thumbnail of Study of the energy consumption of a massive free-running building in the Argentinean northwest through monitoring and thermal simulation

Energy and Buildings, Apr 1, 2012

The investigation presented in this paper has three main objectives. The first one is to study, t... more The investigation presented in this paper has three main objectives. The first one is to study, through a case study, if it is possible to acceptably predict the energy consumption of a massive residential freerunning building, when the exact behavior of the occupants is unknown or actual indoor conditions are not monitored, assuming standard use and occupation schedules, for the dry climate of the Argentinean Northwest. The second objective of the paper is to detect the possible causes of differences between actual and predicted energy consumption through an exhaustive thermal monitoring and occupant's behavior, in order to obtain an improved model of the building giving more accurate predictions of the energy consumption. The third objective is to analyze the effect on the annual energy consumption of changing the massive envelope by a lightweight one. The comparison of real and simulated consumptions under comfort conditions defined by ASHRAE Standard 55 shows that simulations overestimated the energy consumption for heating and cooling. The main causes were detected from the experimental monitoring, indicating a lower use of the air conditioning equipment than the supposed initially. Simulations were improved to consider actual use and occupation conditions. Finally, an annual simulation of the improved model performed by changing the envelope material to a lightweight one showed that energy consumption for heating was increased, while energy consumption for cooling was decreased. In an annual balance, the massive walls are preferable over lightweight ones in arid sunny climates as in the Argentinean Northwest, giving energy savings of around 25%.

Research paper thumbnail of Thermal Evaluation and Modeling of a Double-pass Solar Collector for Air Heating

Research paper thumbnail of Modelización y simulación computacional de acumuladores de calor de lecho de piedras para aplicaciones solares térmicas

Avances en Energías Renovables y Medio Ambiente - AVERMA, 2013

Research paper thumbnail of Optimización del área de colección y del flujo de aire de un colector solar de aire de doble flujo mediante simulación con SIMUSOL

Avances en Energías Renovables y Medio Ambiente - AVERMA, 2013

RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colecc... more RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colección de un colector solar de doble flujo en contracorriente previamente estudiado, teniendo en cuenta no sólo los aspectos térmicos de maximización de la eficiencia sino también aspectos económicos y de funcionamiento. El estudio se realiza para condiciones climáticas correspondientes al período invernal de la Ciudad de Salta, en base a un modelo térmico obtenido previamente mediante el software SIMUSOL y validado con datos experimentales. Los resultados obtenidos indican que es térmica y económicamente conveniente trabajar con una longitud de colección de 2.4 metros y una velocidad del aire de 4m/s, lo cual resulta en una eficiencia global del 80% y una temperatura de salida del aire de alrededor de 40ºC, la cual se considera aceptable para su utilización en calefacción de ambientes interiores residenciales de la Ciudad de Salta. Palabras clave: Colector solar, doble flujo, simulación, velocidad de aire, flujo óptimo, longitud óptima. INTRODUCCIÓN La utilización de colectores solares para calefacción de ambientes interiores es una alternativa viable para disminuir el consumo de energía convencional de los edificios. En trabajos previos se avanzó en el estudio de un colector solar de doble flujo en contracorriente. Dicho colector cuenta con un área de colección útil de 2m 2 (0.83m de ancho x 2.40m de largo). El aire proveniente del ambiente exterior ingresa por la boca de entrada ubicada en el lateral superior del colector recorriendo su primer paso entre la cubierta de policarbonato alveolar (6mm) y la placa absorbedora, y retorna en su segundo paso por debajo de la placa absorbedora (Figura 1). El colector se encuentra aislado térmicamente en los laterales y parte baja con lana de vidrio de 5cm de espesor, como así también el circuito de salida por donde circula el aire hasta llegar al ventilador. Toda la estructura del colector, la placa absorbedora, la boca de extensión, la caja del ventilador, están construidos con el mismo material de chapa galvanizada plana calibre 27. La placa absorbedora se encuentra cubierta con esmalte negro resistente a las altas temperaturas.

Research paper thumbnail of Evaluación térmica y de confort en salas del cabildo de Salta en invierno

Avances en Energías Renovables y Medio Ambiente - AVERMA, Aug 5, 2020

En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabi... more En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabildo de Salta, sede actual del Museo Histórico del Norte, con el objeto de estudiar en el futuro las tecnologías aplicables a la envolvente que permitan disminuir el consumo energético y mejorar las condiciones higrotérmicas interiores de edificios con valor patrimonial. En este tipo de edificios la rehabilitación energética debe ser respetuosa y no invasiva. Para un periodo de 15 días de invierno, se recopilaron datos de temperatura y humedad en diferentes espacios del edificio a intervalos de 15 minutos. Los locales relevados funcionan actualmente como salas de exposición del museo, oficinas administrativas y talleres de conservación o reservas del museo. Se incluyó en el análisis una evaluación de las condiciones de confort según ASHRAE-55 (Voto Medio Predicho y Porcentaje de Personas Insatisfechas), como así también las condiciones de conservación de los objetos expuestos, en un grupo de cuatro espacios destinados a salas de exposiciones.Fil: Gea Salim, Camila. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; ArgentinaFil: Hongn, Marcos Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; ArgentinaFil: González, Silvina Mariana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; ArgentinaFil: Flores Larsen, Silvana Elinor. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; Argentin

Research paper thumbnail of Evaluación térmica y de confort en salas del cabildo de Salta en invierno

En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabi... more En este trabajo se realizaron estudios de las condiciones térmicas del ambiente interior del Cabildo de Salta, sede actual del Museo Histórico del Norte, con el objeto de estudiar en el futuro las tecnologías aplicables a la envolvente que permitan disminuir el consumo energético y mejorar las condiciones higrotérmicas interiores de edificios con valor patrimonial. En este tipo de edificios la rehabilitación energética debe ser respetuosa y no invasiva. Para un periodo de 15 días de invierno, se recopilaron datos de temperatura y humedad en diferentes espacios del edificio a intervalos de 15 minutos. Los locales relevados funcionan actualmente como salas de exposición del museo, oficinas administrativas y talleres de conservación o reservas del museo. Se incluyó en el análisis una evaluación de las condiciones de confort según ASHRAE-55 (Voto Medio Predicho y Porcentaje de Personas Insatisfechas), como así también las condiciones de conservación de los objetos expuestos, en un grupo...

Research paper thumbnail of Determinación in situ de la resistencia térmica de muros en edificios históricos: métodos estacionario y dinámicos

Avances en Energías Renovables y Medio Ambiente - AVERMA, Dec 1, 2019

Research paper thumbnail of Optimización del área de colección y del flujo de aire de un colector solar de aire de doble flujo mediante simulación con SIMUSOL

Avances en Energías Renovables y Medio Ambiente - AVERMA, 2013

RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colecc... more RESUMEN: En el presente artículo se aborda la optimización del flujo de aire y del área de colección de un colector solar de doble flujo en contracorriente previamente estudiado, teniendo en cuenta no sólo los aspectos térmicos de maximización de la eficiencia sino también aspectos económicos y de funcionamiento. El estudio se realiza para condiciones climáticas correspondientes al período invernal de la Ciudad de Salta, en base a un modelo térmico obtenido previamente mediante el software SIMUSOL y validado con datos experimentales. Los resultados obtenidos indican que es térmica y económicamente conveniente trabajar con una longitud de colección de 2.4 metros y una velocidad del aire de 4m/s, lo cual resulta en una eficiencia global del 80% y una temperatura de salida del aire de alrededor de 40ºC, la cual se considera aceptable para su utilización en calefacción de ambientes interiores residenciales de la Ciudad de Salta. Palabras clave: Colector solar, doble flujo, simulación, velocidad de aire, flujo óptimo, longitud óptima. INTRODUCCIÓN La utilización de colectores solares para calefacción de ambientes interiores es una alternativa viable para disminuir el consumo de energía convencional de los edificios. En trabajos previos se avanzó en el estudio de un colector solar de doble flujo en contracorriente. Dicho colector cuenta con un área de colección útil de 2m 2 (0.83m de ancho x 2.40m de largo). El aire proveniente del ambiente exterior ingresa por la boca de entrada ubicada en el lateral superior del colector recorriendo su primer paso entre la cubierta de policarbonato alveolar (6mm) y la placa absorbedora, y retorna en su segundo paso por debajo de la placa absorbedora (Figura 1). El colector se encuentra aislado térmicamente en los laterales y parte baja con lana de vidrio de 5cm de espesor, como así también el circuito de salida por donde circula el aire hasta llegar al ventilador. Toda la estructura del colector, la placa absorbedora, la boca de extensión, la caja del ventilador, están construidos con el mismo material de chapa galvanizada plana calibre 27. La placa absorbedora se encuentra cubierta con esmalte negro resistente a las altas temperaturas.

Research paper thumbnail of Comportamiento térmico del Cabildo de Salta en verano

Avances en Energías Renovables y Medio Ambiente, Dec 30, 2020

Research paper thumbnail of Estudio experimental de un colector solar calentador de aire de doble flujo: resultados preliminares

Research paper thumbnail of Cargas Termicas De Edificios en Estado Transitorio: Su Influencia en El Dimensionamiento De Colectores Solares De Aire

Research paper thumbnail of Análisis del comportamiento térmico de una enredadera mediante termografía infrarroja

The objective of this work is to study the thermal behaviour of a climbing plant through infrared... more The objective of this work is to study the thermal behaviour of a climbing plant through infrared thermography and the determination of its dependance on the solar irradiation. For that aim a method was developed to measure the temperature profile in the depth of the climbing plant canopy through a cuantitative analysis of thermographic images, and the temperature distribution was determined for superficial and profound canopy layers. A linear correlation was found between the differences of this temperatures with the ambient temperature and the total incident radiant energy during the hour before solar noon, for winter conditions. The scope of the method was analized and the means to improve it for future applications in the validation of thermal simulation models of the building's envelope.

Research paper thumbnail of Modelizacion numerica de un colector solar calentador de aire con matriz porosa metálica

Fil: Hernandez, Alejandro Luis. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centr... more Fil: Hernandez, Alejandro Luis. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnologico Salta. Instituto de Investigaciones En Energia No Convencional; Argentina. Universidad Nacional de Salta; Argentina

Research paper thumbnail of Ensayo de un colector solar calentador de aire de doble paso con matriz porosa para el calentamiento de edificios

Fil: Gonzalez, Silvina Mariana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centr... more Fil: Gonzalez, Silvina Mariana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnologico Conicet - Salta. Instituto de Investigaciones en Energia No Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Fisica. Instituto de Investigaciones en Energia No Convencional; Argentina

Research paper thumbnail of Comparison of four in-situ methods for the determination of walls thermal resistance in free-running buildings with alternating heat flux in different seasons

Construction and Building Materials, 2019

h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied... more h i g h l i g h t s Four in-situ methods for determining thermal resistance of walls were studied. Free-running buildings with alternating heat flux were analyzed. Data included simulations and experimental data of four wall-types. Effect of the measuring conditions on convergence was studied. The Pentaur dynamic method produces the most accurate results in all cases.

Research paper thumbnail of Preventive treatments for breast cancer: recent developments

Clinical and Translational Oncology, 2014

Breast cancer is a burden for western societies, and an increasing one in emerging economies, bec... more Breast cancer is a burden for western societies, and an increasing one in emerging economies, because of its high incidence and enormous psychological, social, sanitary and economic costs. However, breast cancer is a preventable disease in a significant proportion. Recent developments in the armamentarium of effective drugs for breast cancer prevention (namely exemestane and anastrozole), the new recommendation from the National Institute for Health and Care Excellence to use preventative drugs in women at high risk as well as updated Guidelines from the US Preventive Services Task Force and the American Society of Clinical Oncology should give renewed momentum to the pharmacological prevention of breast cancer. In this article we review recent major developments in the field and examine their ongoing repercussion for breast cancer prevention. As a practical example, the potential impact of preventive measures in Spain is evaluated and a course of practical actions is delineated.

Research paper thumbnail of Study of the energy consumption of a massive free-running building in the Argentinean northwest through monitoring and thermal simulation

Energy and Buildings, 2012

The investigation presented in this paper has three main objectives. The first one is to study, t... more The investigation presented in this paper has three main objectives. The first one is to study, through a case study, if it is possible to acceptably predict the energy consumption of a massive residential freerunning building, when the exact behavior of the occupants is unknown or actual indoor conditions are not monitored, assuming standard use and occupation schedules, for the dry climate of the Argentinean Northwest. The second objective of the paper is to detect the possible causes of differences between actual and predicted energy consumption through an exhaustive thermal monitoring and occupant's behavior, in order to obtain an improved model of the building giving more accurate predictions of the energy consumption. The third objective is to analyze the effect on the annual energy consumption of changing the massive envelope by a lightweight one. The comparison of real and simulated consumptions under comfort conditions defined by ASHRAE Standard 55 shows that simulations overestimated the energy consumption for heating and cooling. The main causes were detected from the experimental monitoring, indicating a lower use of the air conditioning equipment than the supposed initially. Simulations were improved to consider actual use and occupation conditions. Finally, an annual simulation of the improved model performed by changing the envelope material to a lightweight one showed that energy consumption for heating was increased, while energy consumption for cooling was decreased. In an annual balance, the massive walls are preferable over lightweight ones in arid sunny climates as in the Argentinean Northwest, giving energy savings of around 25%.

Research paper thumbnail of Modelización y Simulación Computacional De Acumuladores De Calor De Lecho De Piedras Para Aplicaciones Solares Térmicas

The aim of this paper is to analyze the influence of different parameters on the thermo-energetic... more The aim of this paper is to analyze the influence of different parameters on the thermo-energetic behaviour of a heat storage packed bed through the development of a computational tool based on the mathematical model of Schumann. Starting fromthe local energy balances, algebraic and differential equations that describe the temperature distribution inside it and the amounts of energy stored and extracted from the bed were obtained. These equations were discretized and transformed into computational algorithms with which the PETRA software was developed and the influence of rock type, bed length and the direction of rotation of the fan on the extractable energy from the accumulator were evaluated. The pressure difference along the bed was also evaluated. The results indicate that more energy can be extracted from the accumulator using an invertible rotation fan, being higher the overall efficiency of the collector-accumulator system.