Stanislav Bilyk - Academia.edu (original) (raw)

Related Authors

Ahmet Cilingir

Leonid  Solomin

Leonid Solomin

R.R.Vreden Russian Research Institute of Traumatology and Orthopedics

Mine Gülden Polat

Murugaiyan Sivasankar

Antonio Apicella

Wojciech Pepke

Uploads

Papers by Stanislav Bilyk

Research paper thumbnail of Finite-element study of the customized implant for revision hip replacement

This work examines a biomechanical system consisting of the hip endoprosthesis and bones of the p... more This work examines a biomechanical system consisting of the hip endoprosthesis and bones of the pelvic region of a person under a load corresponding to the equilibrium of a person in double-supported state. An assessment of the strength of a customised endoprosthesis has been carried out based on the analysis of the stress-strain state of the finite element model of the “skeleton – hip prosthesis” system when tightening the screws and when the system is subjected the person's weight; dangerous areas of the pelvic bone with high level of stresses have been identified. As recommendations, optimization of the location and number of screws used in order to create a more uniform stress distribution is proposed.

Research paper thumbnail of Standard Versus Custom-Made Acetabular Implants in Revision Total Hip Arthroplasty

The Journal of Arthroplasty

Research paper thumbnail of The experimental study of tissue integration into porous titanium implants

HIP International

Introduction: Due to a lack of uniform shapes and sizes of bone defects in hip and knee joint pat... more Introduction: Due to a lack of uniform shapes and sizes of bone defects in hip and knee joint pathology, their fixing could benefit from using individually manufactured 3D-printed highly porous titanium implants. The objective of this study was to evaluate the extent of bone and muscle tissue integration into porous titanium implants manufactured using additive technology. Materials and methods: Porous and non-porous titanium plates were implanted into the latissimus dorsi muscle and tibia of 9 rabbits. On days 1, 60 and 90 animals were examined with x-rays. On day 60 histological tests were carried out. On day 90 the tensile strength at the implant-tissue interface was tested. Results: Histological analysis of muscle samples with porous titanium implants showed integration of connective tissue and blood vessels into the pores. Bone defect analysis demonstrated bone ingrowth into the pores of titanium with a minimal amount of fibrous tissue. The tensile strength of the muscular tiss...

Research paper thumbnail of Acetabular cup version modelling and its clinical applying on plain radiograms

World journal of orthopedics, Jan 18, 2017

To measure the sensitivity and specificity of the cup version assessment by using only anteropost... more To measure the sensitivity and specificity of the cup version assessment by using only anteroposterior hip and pelvis views, evaluate the incidence of inadequate cup version in patients with repeated dislocations after total hip arthroplasty (THA). Radiographic retrospective analysis of 2 groups of patients, with follow up of 6-60 mo, after undergoing primary THA. First group of 32 patients (20 female, 12 male) with unilateral THA (32 hips) required early revision arthroplasty for reasons of dislocation. The mean age and mode were 59 (from 38 to 83) and 66 ages respectively. The average body mass index (BMI) was 24.2 (from 17.7 to 36.3), mode 23.9. Second group was consisted of 164 patients (101 female, 63 male) without dislocations during the follow-up period (170 hips). Among them 6 patients required bilateral THA. The mean age was 60 (from 38 to 84) and mode 59. BMI was 24.8 (17.2-36.8), mode 25.2. Clinical significance of the cup anteversion sign was estimated with cross tabulat...

Research paper thumbnail of Finite-element study of the customized implant for revision hip replacement

This work examines a biomechanical system consisting of the hip endoprosthesis and bones of the p... more This work examines a biomechanical system consisting of the hip endoprosthesis and bones of the pelvic region of a person under a load corresponding to the equilibrium of a person in double-supported state. An assessment of the strength of a customised endoprosthesis has been carried out based on the analysis of the stress-strain state of the finite element model of the “skeleton – hip prosthesis” system when tightening the screws and when the system is subjected the person's weight; dangerous areas of the pelvic bone with high level of stresses have been identified. As recommendations, optimization of the location and number of screws used in order to create a more uniform stress distribution is proposed.

Research paper thumbnail of Standard Versus Custom-Made Acetabular Implants in Revision Total Hip Arthroplasty

The Journal of Arthroplasty

Research paper thumbnail of The experimental study of tissue integration into porous titanium implants

HIP International

Introduction: Due to a lack of uniform shapes and sizes of bone defects in hip and knee joint pat... more Introduction: Due to a lack of uniform shapes and sizes of bone defects in hip and knee joint pathology, their fixing could benefit from using individually manufactured 3D-printed highly porous titanium implants. The objective of this study was to evaluate the extent of bone and muscle tissue integration into porous titanium implants manufactured using additive technology. Materials and methods: Porous and non-porous titanium plates were implanted into the latissimus dorsi muscle and tibia of 9 rabbits. On days 1, 60 and 90 animals were examined with x-rays. On day 60 histological tests were carried out. On day 90 the tensile strength at the implant-tissue interface was tested. Results: Histological analysis of muscle samples with porous titanium implants showed integration of connective tissue and blood vessels into the pores. Bone defect analysis demonstrated bone ingrowth into the pores of titanium with a minimal amount of fibrous tissue. The tensile strength of the muscular tiss...

Research paper thumbnail of Acetabular cup version modelling and its clinical applying on plain radiograms

World journal of orthopedics, Jan 18, 2017

To measure the sensitivity and specificity of the cup version assessment by using only anteropost... more To measure the sensitivity and specificity of the cup version assessment by using only anteroposterior hip and pelvis views, evaluate the incidence of inadequate cup version in patients with repeated dislocations after total hip arthroplasty (THA). Radiographic retrospective analysis of 2 groups of patients, with follow up of 6-60 mo, after undergoing primary THA. First group of 32 patients (20 female, 12 male) with unilateral THA (32 hips) required early revision arthroplasty for reasons of dislocation. The mean age and mode were 59 (from 38 to 83) and 66 ages respectively. The average body mass index (BMI) was 24.2 (from 17.7 to 36.3), mode 23.9. Second group was consisted of 164 patients (101 female, 63 male) without dislocations during the follow-up period (170 hips). Among them 6 patients required bilateral THA. The mean age was 60 (from 38 to 84) and mode 59. BMI was 24.8 (17.2-36.8), mode 25.2. Clinical significance of the cup anteversion sign was estimated with cross tabulat...

Log In