Yufeng Zhou - Academia.edu (original) (raw)
Papers by Yufeng Zhou
Ultrasound in Medicine & Biology, 2002
Journal of Modern Mechanical Engineering and Technology
Purpose: Surgery is necessary for the treatment of an anal fistula. However, excision of some sph... more Purpose: Surgery is necessary for the treatment of an anal fistula. However, excision of some sphincter muscle would compromise sphincter integrity or function, which is the cause of a reduced success rate in the long term. In order to develop an appropriate surgical plan, a mathematical model that describes the relationship between the internal pressure of the anal canal and the structure of anal sphincters is required. Methods: The anatomical structure of the anal canal and the corresponding sphincter pressure can be measured by endoanal ultrasound (EAUS) imaging and manometry, respectively. Length-tension relationships for skeletal and smooth muscles, two major components of the external and internal anal sphincter, respectively, were reviewed first. Results: Based on the information about the internal and external sphincters, two mathematical models, the thick-wall cylinder model and the two-layer model, have been created, from which the influence of complete or partial excision of the sphincter muscle can be estimated. Conclusions: The proposed thick-wall cylinder and two-layer models could describe the relationship between the internal anal canal pressure and the structure of anal sphincters, from which the influence of complete or partial excision of the sphincter muscle may be estimated.
AIP Conference Proceedings, 2017
Extracorporeal shock wave lithotripsy (ESWL) has been used widely in the noninvasive treatment of... more Extracorporeal shock wave lithotripsy (ESWL) has been used widely in the noninvasive treatment of kidney calculi. The fine fragments less than 2 mm in size can be discharged by urination, which determines the success of ESWL. Although ultrasonic and fluorescent imaging are used to localize the calculi, it's challenging to monitor the stone comminution progress, especially at the late stage of ESWL when fragments spread out as a cloud. The lack of real-time and quantitative evaluation makes this procedure semi-blind, resulting in either under-or over-treatment after the legal number of pulses required by FDA. The time reversal operator (TRO) method has the ability to detect point-like scatterers, and the number of non-zero eigenvalues of TRO is equal to that of the scatterers. In this study, the validation of TRO method to identify stones was illustrated from both numerical and experimental results for one to two stones with various sizes and locations. Furthermore, the parameters affecting the performance of TRO method has also been investigated. Overall, TRO method is effective in identifying the fragments in a stone cluster in real-time. Further development of a detection system and evaluation of its performance both in vitro and in vivo during ESWL is necessary for application.
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, Jan 25, 2017
Low-intensity ultrasound (LIUS) has been shown to enhance bone and cartilage regeneration from st... more Low-intensity ultrasound (LIUS) has been shown to enhance bone and cartilage regeneration from stem cells. The ease of its incorporation makes it an attractive mechanical stimulus for not only osteogenesis and chondrogenesis, but also cardiomyogenesis. However, to date, no study has investigated its effects on cardiomyogenesis from embryonic stem cells. In this study, murine embryonic stem cells were differentiated via embryoid body formation and plating, and after 3 days they were subjected to daily 10 minutes of LIUS treatment with various conditions: (1) low-pulsed (21 mW/cm(2) , 20% duty cycle), (2) low-continuous, (3) high-pulsed (147 mW/cm(2) , 20% duty cycle), and (4) high-continuous LIUS. Low-pulsed and high-continuous LIUS had improved beating rates of contractile areas as well as increased late cardiac gene expressions, such as α- and β-myosin heavy chain and cardiac troponin T, showing its benefits on cardiomyocyte differentiation. Meanwhile, an early endodermal marker, α...
Environmental science and pollution research international, Jan 15, 2016
In this study, a novel chemical-free approach for cleaning oil-contaminated sand with self-collap... more In this study, a novel chemical-free approach for cleaning oil-contaminated sand with self-collapsing air microbubbles (MBs) with diameter less than 50 μm was developed without the use of chemicals, such as surfactants and alkalis. Diesel and rotary-vane pump oil-contaminated fine and medium sands were treated with MBs to study the effect of oil viscosity and sand grain size on oil removal with MBs. About 95 % of diesel removal was achieved for 24 h old 10 % (w/w) diesel-contaminated medium sand in contrast to only 70 % removal from fine sand after 40-min treatment with MBs. While rotary-vane pump oil removal exceeds that of diesel after 40-min treatment with MBs, combination of mechanical stirring with MBs significantly enhanced the oil removal rate, whereby 95 % diesel removal was achieved from fine sand in 30 min in contrast to only 52 % diesel removal with MBs alone. A possible MBs cleaning mechanism for oil-contaminated sand was also proposed. This study provides experimental e...
Proceedings of the 8th International Symposium on Cavitation, 2012
Bubble cavitation plays an important role in the HIFU ablation as well as histotripsy. The charac... more Bubble cavitation plays an important role in the HIFU ablation as well as histotripsy. The characteristics of bubble cavitation were measured and found vary with the progress of histotripsy treatment. Ultrasound parameters (i.e., frequency and pulse duration) have a great effect on the bubble cavitation and the consequent lesion formation.
AIP Conference Proceedings, 2009
High intensity focused ultrasound (HIFU) is emerging as a modality for treatment of solid tumors.... more High intensity focused ultrasound (HIFU) is emerging as a modality for treatment of solid tumors. The temperature at the focus can reach over 65qC denaturing cellular proteins resulting in coagulative necrosis. Typically, HIFU parameters are the same for each treated spot in most HIFU control systems. Because of thermal diffusion from nearby spots, the size of lesions will gradually become larger as the HIFU therapy progresses, which may cause insufficient treatment of initial spots, and over-treatment of later ones. It is found that the produced lesion pattern also depends on the scanning pathway. From the viewpoint of the physician creating uniform lesions and minimizing energy exposure are preferred in tumor ablation. An algorithm has been developed to adaptively determine the treatment parameters for every spot in a theoretical model in order to maintain similar lesion size throughout the HIFU therapy. In addition, the exposure energy needed using the traditional raster scanning is compared with those of two other scanning pathways, spiral scanning from the center to the outside and from the outside to the center. The theoretical prediction and proposed algorithm were further evaluated using transparent gel phantoms as a target. Digital images of the lesions were obtained, quantified, and then compared with each other. Altogether, dynamically changing treatment parameters can improve the efficacy and safety of HIFU ablation.
10th International Symposium on Therapeutic Ultrasound (Istu 2010), 2011
As an effective and noninvasive therapeutic modality for tumor treatment, high-intensity focused ... more As an effective and noninvasive therapeutic modality for tumor treatment, high-intensity focused ultrasound (HIFU) has attracted attention from both physicians and patients. New generations of HIFU systems with the ability to electrically steer the HIFU focus using phased array transducers have been under development. The presence of side and grating lobes may cause undesired thermal accumulation at the interface of the coupling medium (i.e. water) and skin, or in the intervening tissue. Although sparse randomly distributed piston elements could reduce the amplitude of grating lobes, there are theoretically no grating lobes with the use of concave elements in the new phased array HIFU. A new HIFU transmission strategy is proposed in this study, firing a number of but not all elements for a certain period and then changing to another group for the next firing sequence. The advantages are: 1) the asymmetric position of active elements may reduce the side lobes, and 2) each element has some resting time during the entire HIFU ablation (up to several hours for some clinical applications) so that the decreasing efficiency of the transducer due to thermal accumulation is minimized. Genetic algorithm was used for selecting randomly distributed elements in a HIFU array. Amplitudes of the first side lobes at the focal plane were used as the fitness value in the optimization. Overall, it is suggested that the proposed new strategy could reduce the side lobe and the consequent side-effects, and the genetic algorithm is effective in selecting those randomly distributed elements in a HIFU array.
Ultrasound in Medicine & Biology, 2011
Esophageal and gastric varices are associated with significant morbidity and mortality for cirrho... more Esophageal and gastric varices are associated with significant morbidity and mortality for cirrhotic patients. The current modalities available for treating bleeding esophageal and gastric varices, namely endoscopic band ligation and sclerotherapy, require frequent sessions to obtain effective thrombosis and are associated with significant adverse effects. A more effective therapy that results in long-term vascular occlusion has the potential to improve patient outcomes. In this study, we investigated a new potential method for inducing long-term vascular occlusion by targeting segments of a rabbit's auricular vein in vivo with low duty cycle, high peak rarefaction pressure (9 MPa) pulsed high-intensity focused ultrasound in the presence of intravenously administered ultrasound microbubbles followed by local injection of fibrinogen and a proinflammatory agent (ethanol, cyanoacrylate or morrhuate sodium). The novel method introduced in this study resulted in acute and long-term complete vascular occlusions when injecting a proinflammatory agent with fibrinogen. Future investigation and translational studies are needed to assess its clinical applicability.
Journal of Endourology, 2012
Purpose: A new method was devised to suppress the bubble cavitation in the lithotripter focal zon... more Purpose: A new method was devised to suppress the bubble cavitation in the lithotripter focal zone to reduce the propensity of shockwave-induced renal injury. Materials and Methods: An edge extender was designed and fabricated to fit on the outside of the ellipsoidal reflector of an electrohydraulic lithotripter to disturb the generation of diffraction wave at the aperture, but with little effect on the acoustic field inside the reflector. Results: Although the peak negative pressures at the lithotripter focus using the edge extender at 20 kV were similar to that of the original configuration (-11.1-0.9 vs-10.6-0.7 MPa), the duration of the tensile wave was shortened significantly (3.2-0.54 vs 5.83-0.56 ls, P < 0.01). There is no difference, however, in both the amplitude and duration of the compressive shockwaves between these two configurations as well as the-6 dB beam width in the focal plane. The significant suppression effect of bubble cavitation was confirmed by the measured bubble collapse time using passive cavitation detection. At the lithotripter focus, while only about 30 shocks were needed to rupture a blood vessel phantom using the original HM-3 reflector at 20 kV, no damage could be produced after 300 shocks using the edge extender. Meanwhile, the original HM-3 lithotripter at 20 kV can achieve a stone comminution efficiency of 50.4-2.0% on plaster-of-Paris stone phantom after 200 shocks, which is comparable to that of using the edge extender (46.8-4.1%, P = 0.005). Conclusions: Modifying the diffraction wave at the lithotripter aperture can suppress the shockwave-induced bubble cavitation with significant reduced damage potential on the vessel phantom but satisfactory stone comminution ability.
IEEE Transactions on Biomedical Engineering, 2010
Targeted vascular occlusion is desirable for clinical therapies such as in the treatment of esoph... more Targeted vascular occlusion is desirable for clinical therapies such as in the treatment of esophageal and gastric varices and varicose veins. The feasibility of ultrasound-mediated endothelial damage for vascular occlusion was studied. A segment of a rabbit auricular vein was treated in vivo with low duty-cycle, high peak rarefaction pressure (9 MPa) high-intensity focused ultrasound (HIFU) pulses in the presence of intravenously administered circulating microbubbles, followed by fibrinogen injection, which resulted in the formation of an acute occlusive intravascular thrombus. Further investigation and refinements of treatment protocols are necessary for producing durable vascular occlusion.
The Journal of the Acoustical Society of America, 2007
High intensity focused ultrasound (HIFU) is being evaluated for noninvasive treatment of solid tu... more High intensity focused ultrasound (HIFU) is being evaluated for noninvasive treatment of solid tumors. The temperature at the HIFU focus can reach over 65<th>°C, denaturing cellular proteins and resulting in coagulative necrosis and lesion formation. One common method for delivering HIFU therapy clinically is using the spot accumulation method that delivers sequential individual treatment spots. Because of thermal diffusion from nearby treatment spots, the size of subsequent lesions will gradually become larger as the HIFU therapy progresses, which may cause insufficient treatment of the initial spots, and over-treatment of later spots unless parameters are changed during treatment. A new pathway for HIFU treatment is proposed and compared with the conventional sequential path. Modeling, in vitro phantom and ex vivo bovine liver experiments demonstrate that the new treatment path produces more uniform lesions than the conventional treatment path (p<0.05). The relationship b...
Ultrasound in Medicine & Biology, 2016
Chemotherapeutic drug delivery is often ineffective within solid tumors, but increasing the drug ... more Chemotherapeutic drug delivery is often ineffective within solid tumors, but increasing the drug dose would result in systemic toxicity. The use of high-intensity focused ultrasound (HIFU) has the potential to enhance penetration of small molecules. However, operation parameters need to be optimized before the use of chemotherapeutic drug in vivo and translation to clinical trial. In this study, the effects of pulsed-HIFU (pHIFU) parameters (spatial-average pulse-average intensity, duty factor, and pulse repetition frequency) to the penetration as well as content of small molecules were evaluated in ex vivo porcine kidneys. Specific HIFU parameters resulted in over 40 times greater Evans blue content and 3.5 times the penetration depth compared to untreated samples. When selected parameters were applied to porcine kidneys in vivo, a 2.3-fold increase in concentration was obtained after a 2-minute pHIFU exposure. Altogether, pHIFU has shown to be an effective modality to enhance both the concentration and penetration depth of small molecules into tissue using the optimized HIFU parameters. Although, performed in normal tissue, this study has the promise of translation into tumor tissue.
International Journal of Hyperthermia, 2017
Purpose: HIFU has been emerging as an effective and safe modality for the treatment of solid tumo... more Purpose: HIFU has been emerging as an effective and safe modality for the treatment of solid tumours and cancers. The focus shifting range of phased array HIFU transducer is an important safety concern because of the presence of grating lobe in the pre-focal region. However, previous studies were only based on linear acoustic wave model. Materials and methods: The nonlinear wave propagation from a 256-element phased array through multiple layered media was simulated using the angular spectrum approach (ASA) in marching fractional steps with the consideration of diffraction, attenuation and non-linearity effects by a secondorder operator splitting scheme. The distribution of acoustic intensities, temperature elevations, lesion sizes and grating lobe levels were calculated at various axially post-focal shifting distances and driving frequencies. Results: Axially shifting HIFU focus leads to significant increase of the acoustic intensity at the grating lobe, but decrease at the main lobe. The influences on the acoustic field, thermal field and lesion sizes are determined by the shifting distance and driving frequency, and variations can be fit monotonically and linearly. Prediction accuracies by simple regression models are satisfactory. Irreversible tissue coagulation could be generated by the grating lobe at certain conditions. Conclusions: The established nonlinear wave propagation algorithm allows the accurate description of HIFU field and consequently the evaluation of grating lobe and steerability of focus. The influence of focus shifting may be predicted simply. The treatment planning of phased array HIFU ablation could be optimised by setting the appropriate exposure and focus scanning schemes.
International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2016
HIFU becomes an effective and non-invasive modality of solid tumour/cancer ablation. Simulation o... more HIFU becomes an effective and non-invasive modality of solid tumour/cancer ablation. Simulation of the non-linear acoustic wave propagation using a phased-array transducer in multiple layered media using different focusing strategies and the consequent lesion formation are essential in HIFU planning in order to enhance the efficacy and efficiency of treatment. An angular spectrum approach with marching fractional steps was applied in the wave propagation from phased-array HIFU transducer, and diffraction, attenuation, and non-linearity effects were accounted for by a second-order operator splitting scheme. The simulated distributions of the first three harmonics along and transverse to the transducer axis were compared to the hydrophone measurements. The bioheat equation was used to simulate the subsequent temperature elevation using the deposited acoustic energy, and lesion formation was determined by the thermal dose. Better agreement was found between the measured harmonics distr...
Physics Procedia, 2015
Liver ablation is challenging in high-intensity focused ultrasound (HIFU) because of the presence... more Liver ablation is challenging in high-intensity focused ultrasound (HIFU) because of the presence of ribs and great inhomogeneity in multi-layer tissue. In this study, angular spectrum approach (ASA) has been used in the wave propagation from phased-array HIFU transducer, and diffraction, attenuation and the nonlinearity are accounted for by means of second order operator splitting method. Bioheat equation is used to simulate the subsequent temperature elevation and lesion formation with the formation of shifted focus and multiple foci. In summary, our approach could simulate the performance of phased-array HIFU in the clinics and then develop an appropriate treatment plan.
Ultrasonics, 2018
Cavitation histotripsy with the short pulse duration (PD) but high pulse repetition frequency (PR... more Cavitation histotripsy with the short pulse duration (PD) but high pulse repetition frequency (PRF) disintegrates the tissue at a fluid interface. However, longer PD and lower PRF are used in the other focused ultrasound applications, where the acoustic radiation force, streaming, and cavitation are different, and their effects on erosion are unknown. In this study, the erosion at the surface of phantom/ex vivo tissue and the characteristics of induced bubble cloud captured by high-speed photography, passive cavitation detection, and light transmission during histotripsy exposure at varied PDs and PRFs but the same duty cycle were compared. The peak negative pressure of 6.6 MPa at the PD of 20 ms and PRF of 1 Hz began to erode the phantom, which becomes more significant with the increase of peak negative pressure, PD, and interval time between bursts. The increase of the PRF from 1 Hz to 1000 Hz, while the decrease of the PD from 20 ms to 20 s (duty cycle of 2%) at the same energy was delivered to the gel phantom immersed in the degassed water led to the decrease of erosion volume but a slight increase of the erosion area and smoother surface. Low PRF and long PD produce the significant tissue deformation, acoustic wave refocusing, confinement of bubbles in a conical region, and more bubble dissolution after the collapse for the high acoustic scattering and light transmission signals. In comparison, high PRF and low PD produce a wide distribution of bubbles with only little wave refocusing at the beginning of cavitation histotripsy and high inertial cavitation. Acoustic emission dose has a good correlation with the erosion volume. The erosion on the porcine kidney at the varied PRFs and PDs with the same energy output showed similar trends as those in the phantom but at a slow rate. In summary, the PRF and PD are important parameters for the cavitation histotripsy-induced erosion at the interface of fluid and soft material, and they should be optimized for the best outcome.
Journal of The Acoustical Society of America, 2000
Rupture of small blood vessels is often observed in vivo following shock wave lithotripsy (SWL), ... more Rupture of small blood vessels is often observed in vivo following shock wave lithotripsy (SWL), and cavitation has been implicated as a potential mechanism for the injury. To understand more precisely the underlying mechanical process of the injury, the dynamics of SWL‐ ...
Journal of Vibration Engineering & Technologies
Journal of Medical and Biological Engineering
Ultrasound in Medicine & Biology, 2002
Journal of Modern Mechanical Engineering and Technology
Purpose: Surgery is necessary for the treatment of an anal fistula. However, excision of some sph... more Purpose: Surgery is necessary for the treatment of an anal fistula. However, excision of some sphincter muscle would compromise sphincter integrity or function, which is the cause of a reduced success rate in the long term. In order to develop an appropriate surgical plan, a mathematical model that describes the relationship between the internal pressure of the anal canal and the structure of anal sphincters is required. Methods: The anatomical structure of the anal canal and the corresponding sphincter pressure can be measured by endoanal ultrasound (EAUS) imaging and manometry, respectively. Length-tension relationships for skeletal and smooth muscles, two major components of the external and internal anal sphincter, respectively, were reviewed first. Results: Based on the information about the internal and external sphincters, two mathematical models, the thick-wall cylinder model and the two-layer model, have been created, from which the influence of complete or partial excision of the sphincter muscle can be estimated. Conclusions: The proposed thick-wall cylinder and two-layer models could describe the relationship between the internal anal canal pressure and the structure of anal sphincters, from which the influence of complete or partial excision of the sphincter muscle may be estimated.
AIP Conference Proceedings, 2017
Extracorporeal shock wave lithotripsy (ESWL) has been used widely in the noninvasive treatment of... more Extracorporeal shock wave lithotripsy (ESWL) has been used widely in the noninvasive treatment of kidney calculi. The fine fragments less than 2 mm in size can be discharged by urination, which determines the success of ESWL. Although ultrasonic and fluorescent imaging are used to localize the calculi, it's challenging to monitor the stone comminution progress, especially at the late stage of ESWL when fragments spread out as a cloud. The lack of real-time and quantitative evaluation makes this procedure semi-blind, resulting in either under-or over-treatment after the legal number of pulses required by FDA. The time reversal operator (TRO) method has the ability to detect point-like scatterers, and the number of non-zero eigenvalues of TRO is equal to that of the scatterers. In this study, the validation of TRO method to identify stones was illustrated from both numerical and experimental results for one to two stones with various sizes and locations. Furthermore, the parameters affecting the performance of TRO method has also been investigated. Overall, TRO method is effective in identifying the fragments in a stone cluster in real-time. Further development of a detection system and evaluation of its performance both in vitro and in vivo during ESWL is necessary for application.
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, Jan 25, 2017
Low-intensity ultrasound (LIUS) has been shown to enhance bone and cartilage regeneration from st... more Low-intensity ultrasound (LIUS) has been shown to enhance bone and cartilage regeneration from stem cells. The ease of its incorporation makes it an attractive mechanical stimulus for not only osteogenesis and chondrogenesis, but also cardiomyogenesis. However, to date, no study has investigated its effects on cardiomyogenesis from embryonic stem cells. In this study, murine embryonic stem cells were differentiated via embryoid body formation and plating, and after 3 days they were subjected to daily 10 minutes of LIUS treatment with various conditions: (1) low-pulsed (21 mW/cm(2) , 20% duty cycle), (2) low-continuous, (3) high-pulsed (147 mW/cm(2) , 20% duty cycle), and (4) high-continuous LIUS. Low-pulsed and high-continuous LIUS had improved beating rates of contractile areas as well as increased late cardiac gene expressions, such as α- and β-myosin heavy chain and cardiac troponin T, showing its benefits on cardiomyocyte differentiation. Meanwhile, an early endodermal marker, α...
Environmental science and pollution research international, Jan 15, 2016
In this study, a novel chemical-free approach for cleaning oil-contaminated sand with self-collap... more In this study, a novel chemical-free approach for cleaning oil-contaminated sand with self-collapsing air microbubbles (MBs) with diameter less than 50 μm was developed without the use of chemicals, such as surfactants and alkalis. Diesel and rotary-vane pump oil-contaminated fine and medium sands were treated with MBs to study the effect of oil viscosity and sand grain size on oil removal with MBs. About 95 % of diesel removal was achieved for 24 h old 10 % (w/w) diesel-contaminated medium sand in contrast to only 70 % removal from fine sand after 40-min treatment with MBs. While rotary-vane pump oil removal exceeds that of diesel after 40-min treatment with MBs, combination of mechanical stirring with MBs significantly enhanced the oil removal rate, whereby 95 % diesel removal was achieved from fine sand in 30 min in contrast to only 52 % diesel removal with MBs alone. A possible MBs cleaning mechanism for oil-contaminated sand was also proposed. This study provides experimental e...
Proceedings of the 8th International Symposium on Cavitation, 2012
Bubble cavitation plays an important role in the HIFU ablation as well as histotripsy. The charac... more Bubble cavitation plays an important role in the HIFU ablation as well as histotripsy. The characteristics of bubble cavitation were measured and found vary with the progress of histotripsy treatment. Ultrasound parameters (i.e., frequency and pulse duration) have a great effect on the bubble cavitation and the consequent lesion formation.
AIP Conference Proceedings, 2009
High intensity focused ultrasound (HIFU) is emerging as a modality for treatment of solid tumors.... more High intensity focused ultrasound (HIFU) is emerging as a modality for treatment of solid tumors. The temperature at the focus can reach over 65qC denaturing cellular proteins resulting in coagulative necrosis. Typically, HIFU parameters are the same for each treated spot in most HIFU control systems. Because of thermal diffusion from nearby spots, the size of lesions will gradually become larger as the HIFU therapy progresses, which may cause insufficient treatment of initial spots, and over-treatment of later ones. It is found that the produced lesion pattern also depends on the scanning pathway. From the viewpoint of the physician creating uniform lesions and minimizing energy exposure are preferred in tumor ablation. An algorithm has been developed to adaptively determine the treatment parameters for every spot in a theoretical model in order to maintain similar lesion size throughout the HIFU therapy. In addition, the exposure energy needed using the traditional raster scanning is compared with those of two other scanning pathways, spiral scanning from the center to the outside and from the outside to the center. The theoretical prediction and proposed algorithm were further evaluated using transparent gel phantoms as a target. Digital images of the lesions were obtained, quantified, and then compared with each other. Altogether, dynamically changing treatment parameters can improve the efficacy and safety of HIFU ablation.
10th International Symposium on Therapeutic Ultrasound (Istu 2010), 2011
As an effective and noninvasive therapeutic modality for tumor treatment, high-intensity focused ... more As an effective and noninvasive therapeutic modality for tumor treatment, high-intensity focused ultrasound (HIFU) has attracted attention from both physicians and patients. New generations of HIFU systems with the ability to electrically steer the HIFU focus using phased array transducers have been under development. The presence of side and grating lobes may cause undesired thermal accumulation at the interface of the coupling medium (i.e. water) and skin, or in the intervening tissue. Although sparse randomly distributed piston elements could reduce the amplitude of grating lobes, there are theoretically no grating lobes with the use of concave elements in the new phased array HIFU. A new HIFU transmission strategy is proposed in this study, firing a number of but not all elements for a certain period and then changing to another group for the next firing sequence. The advantages are: 1) the asymmetric position of active elements may reduce the side lobes, and 2) each element has some resting time during the entire HIFU ablation (up to several hours for some clinical applications) so that the decreasing efficiency of the transducer due to thermal accumulation is minimized. Genetic algorithm was used for selecting randomly distributed elements in a HIFU array. Amplitudes of the first side lobes at the focal plane were used as the fitness value in the optimization. Overall, it is suggested that the proposed new strategy could reduce the side lobe and the consequent side-effects, and the genetic algorithm is effective in selecting those randomly distributed elements in a HIFU array.
Ultrasound in Medicine & Biology, 2011
Esophageal and gastric varices are associated with significant morbidity and mortality for cirrho... more Esophageal and gastric varices are associated with significant morbidity and mortality for cirrhotic patients. The current modalities available for treating bleeding esophageal and gastric varices, namely endoscopic band ligation and sclerotherapy, require frequent sessions to obtain effective thrombosis and are associated with significant adverse effects. A more effective therapy that results in long-term vascular occlusion has the potential to improve patient outcomes. In this study, we investigated a new potential method for inducing long-term vascular occlusion by targeting segments of a rabbit's auricular vein in vivo with low duty cycle, high peak rarefaction pressure (9 MPa) pulsed high-intensity focused ultrasound in the presence of intravenously administered ultrasound microbubbles followed by local injection of fibrinogen and a proinflammatory agent (ethanol, cyanoacrylate or morrhuate sodium). The novel method introduced in this study resulted in acute and long-term complete vascular occlusions when injecting a proinflammatory agent with fibrinogen. Future investigation and translational studies are needed to assess its clinical applicability.
Journal of Endourology, 2012
Purpose: A new method was devised to suppress the bubble cavitation in the lithotripter focal zon... more Purpose: A new method was devised to suppress the bubble cavitation in the lithotripter focal zone to reduce the propensity of shockwave-induced renal injury. Materials and Methods: An edge extender was designed and fabricated to fit on the outside of the ellipsoidal reflector of an electrohydraulic lithotripter to disturb the generation of diffraction wave at the aperture, but with little effect on the acoustic field inside the reflector. Results: Although the peak negative pressures at the lithotripter focus using the edge extender at 20 kV were similar to that of the original configuration (-11.1-0.9 vs-10.6-0.7 MPa), the duration of the tensile wave was shortened significantly (3.2-0.54 vs 5.83-0.56 ls, P < 0.01). There is no difference, however, in both the amplitude and duration of the compressive shockwaves between these two configurations as well as the-6 dB beam width in the focal plane. The significant suppression effect of bubble cavitation was confirmed by the measured bubble collapse time using passive cavitation detection. At the lithotripter focus, while only about 30 shocks were needed to rupture a blood vessel phantom using the original HM-3 reflector at 20 kV, no damage could be produced after 300 shocks using the edge extender. Meanwhile, the original HM-3 lithotripter at 20 kV can achieve a stone comminution efficiency of 50.4-2.0% on plaster-of-Paris stone phantom after 200 shocks, which is comparable to that of using the edge extender (46.8-4.1%, P = 0.005). Conclusions: Modifying the diffraction wave at the lithotripter aperture can suppress the shockwave-induced bubble cavitation with significant reduced damage potential on the vessel phantom but satisfactory stone comminution ability.
IEEE Transactions on Biomedical Engineering, 2010
Targeted vascular occlusion is desirable for clinical therapies such as in the treatment of esoph... more Targeted vascular occlusion is desirable for clinical therapies such as in the treatment of esophageal and gastric varices and varicose veins. The feasibility of ultrasound-mediated endothelial damage for vascular occlusion was studied. A segment of a rabbit auricular vein was treated in vivo with low duty-cycle, high peak rarefaction pressure (9 MPa) high-intensity focused ultrasound (HIFU) pulses in the presence of intravenously administered circulating microbubbles, followed by fibrinogen injection, which resulted in the formation of an acute occlusive intravascular thrombus. Further investigation and refinements of treatment protocols are necessary for producing durable vascular occlusion.
The Journal of the Acoustical Society of America, 2007
High intensity focused ultrasound (HIFU) is being evaluated for noninvasive treatment of solid tu... more High intensity focused ultrasound (HIFU) is being evaluated for noninvasive treatment of solid tumors. The temperature at the HIFU focus can reach over 65<th>°C, denaturing cellular proteins and resulting in coagulative necrosis and lesion formation. One common method for delivering HIFU therapy clinically is using the spot accumulation method that delivers sequential individual treatment spots. Because of thermal diffusion from nearby treatment spots, the size of subsequent lesions will gradually become larger as the HIFU therapy progresses, which may cause insufficient treatment of the initial spots, and over-treatment of later spots unless parameters are changed during treatment. A new pathway for HIFU treatment is proposed and compared with the conventional sequential path. Modeling, in vitro phantom and ex vivo bovine liver experiments demonstrate that the new treatment path produces more uniform lesions than the conventional treatment path (p<0.05). The relationship b...
Ultrasound in Medicine & Biology, 2016
Chemotherapeutic drug delivery is often ineffective within solid tumors, but increasing the drug ... more Chemotherapeutic drug delivery is often ineffective within solid tumors, but increasing the drug dose would result in systemic toxicity. The use of high-intensity focused ultrasound (HIFU) has the potential to enhance penetration of small molecules. However, operation parameters need to be optimized before the use of chemotherapeutic drug in vivo and translation to clinical trial. In this study, the effects of pulsed-HIFU (pHIFU) parameters (spatial-average pulse-average intensity, duty factor, and pulse repetition frequency) to the penetration as well as content of small molecules were evaluated in ex vivo porcine kidneys. Specific HIFU parameters resulted in over 40 times greater Evans blue content and 3.5 times the penetration depth compared to untreated samples. When selected parameters were applied to porcine kidneys in vivo, a 2.3-fold increase in concentration was obtained after a 2-minute pHIFU exposure. Altogether, pHIFU has shown to be an effective modality to enhance both the concentration and penetration depth of small molecules into tissue using the optimized HIFU parameters. Although, performed in normal tissue, this study has the promise of translation into tumor tissue.
International Journal of Hyperthermia, 2017
Purpose: HIFU has been emerging as an effective and safe modality for the treatment of solid tumo... more Purpose: HIFU has been emerging as an effective and safe modality for the treatment of solid tumours and cancers. The focus shifting range of phased array HIFU transducer is an important safety concern because of the presence of grating lobe in the pre-focal region. However, previous studies were only based on linear acoustic wave model. Materials and methods: The nonlinear wave propagation from a 256-element phased array through multiple layered media was simulated using the angular spectrum approach (ASA) in marching fractional steps with the consideration of diffraction, attenuation and non-linearity effects by a secondorder operator splitting scheme. The distribution of acoustic intensities, temperature elevations, lesion sizes and grating lobe levels were calculated at various axially post-focal shifting distances and driving frequencies. Results: Axially shifting HIFU focus leads to significant increase of the acoustic intensity at the grating lobe, but decrease at the main lobe. The influences on the acoustic field, thermal field and lesion sizes are determined by the shifting distance and driving frequency, and variations can be fit monotonically and linearly. Prediction accuracies by simple regression models are satisfactory. Irreversible tissue coagulation could be generated by the grating lobe at certain conditions. Conclusions: The established nonlinear wave propagation algorithm allows the accurate description of HIFU field and consequently the evaluation of grating lobe and steerability of focus. The influence of focus shifting may be predicted simply. The treatment planning of phased array HIFU ablation could be optimised by setting the appropriate exposure and focus scanning schemes.
International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2016
HIFU becomes an effective and non-invasive modality of solid tumour/cancer ablation. Simulation o... more HIFU becomes an effective and non-invasive modality of solid tumour/cancer ablation. Simulation of the non-linear acoustic wave propagation using a phased-array transducer in multiple layered media using different focusing strategies and the consequent lesion formation are essential in HIFU planning in order to enhance the efficacy and efficiency of treatment. An angular spectrum approach with marching fractional steps was applied in the wave propagation from phased-array HIFU transducer, and diffraction, attenuation, and non-linearity effects were accounted for by a second-order operator splitting scheme. The simulated distributions of the first three harmonics along and transverse to the transducer axis were compared to the hydrophone measurements. The bioheat equation was used to simulate the subsequent temperature elevation using the deposited acoustic energy, and lesion formation was determined by the thermal dose. Better agreement was found between the measured harmonics distr...
Physics Procedia, 2015
Liver ablation is challenging in high-intensity focused ultrasound (HIFU) because of the presence... more Liver ablation is challenging in high-intensity focused ultrasound (HIFU) because of the presence of ribs and great inhomogeneity in multi-layer tissue. In this study, angular spectrum approach (ASA) has been used in the wave propagation from phased-array HIFU transducer, and diffraction, attenuation and the nonlinearity are accounted for by means of second order operator splitting method. Bioheat equation is used to simulate the subsequent temperature elevation and lesion formation with the formation of shifted focus and multiple foci. In summary, our approach could simulate the performance of phased-array HIFU in the clinics and then develop an appropriate treatment plan.
Ultrasonics, 2018
Cavitation histotripsy with the short pulse duration (PD) but high pulse repetition frequency (PR... more Cavitation histotripsy with the short pulse duration (PD) but high pulse repetition frequency (PRF) disintegrates the tissue at a fluid interface. However, longer PD and lower PRF are used in the other focused ultrasound applications, where the acoustic radiation force, streaming, and cavitation are different, and their effects on erosion are unknown. In this study, the erosion at the surface of phantom/ex vivo tissue and the characteristics of induced bubble cloud captured by high-speed photography, passive cavitation detection, and light transmission during histotripsy exposure at varied PDs and PRFs but the same duty cycle were compared. The peak negative pressure of 6.6 MPa at the PD of 20 ms and PRF of 1 Hz began to erode the phantom, which becomes more significant with the increase of peak negative pressure, PD, and interval time between bursts. The increase of the PRF from 1 Hz to 1000 Hz, while the decrease of the PD from 20 ms to 20 s (duty cycle of 2%) at the same energy was delivered to the gel phantom immersed in the degassed water led to the decrease of erosion volume but a slight increase of the erosion area and smoother surface. Low PRF and long PD produce the significant tissue deformation, acoustic wave refocusing, confinement of bubbles in a conical region, and more bubble dissolution after the collapse for the high acoustic scattering and light transmission signals. In comparison, high PRF and low PD produce a wide distribution of bubbles with only little wave refocusing at the beginning of cavitation histotripsy and high inertial cavitation. Acoustic emission dose has a good correlation with the erosion volume. The erosion on the porcine kidney at the varied PRFs and PDs with the same energy output showed similar trends as those in the phantom but at a slow rate. In summary, the PRF and PD are important parameters for the cavitation histotripsy-induced erosion at the interface of fluid and soft material, and they should be optimized for the best outcome.
Journal of The Acoustical Society of America, 2000
Rupture of small blood vessels is often observed in vivo following shock wave lithotripsy (SWL), ... more Rupture of small blood vessels is often observed in vivo following shock wave lithotripsy (SWL), and cavitation has been implicated as a potential mechanism for the injury. To understand more precisely the underlying mechanical process of the injury, the dynamics of SWL‐ ...
Journal of Vibration Engineering & Technologies
Journal of Medical and Biological Engineering