IOP conference series, Dec 1, 2019
This Research is focusing to design technical and financial viability of Net Zero Energy Building... more This Research is focusing to design technical and financial viability of Net Zero Energy Building (NZEB) from a study case of existing building in Jakarta, first by reduce Building's energy consumption and employing renewable energy sources. The results showed that energy savings from implementing green building concept could reduce electricity usage by 18%and Return on Investment (ROI) 3.86 years, the utilization of the working scheme of the condenser pump to be used as a micro hydro power plant will generate Electric Power of 733.83 kW and have the potential to replace electricity supply from Grid/PLN by 26% and ROI 3.5 years, the installation of Building Integrated Photovoltaic (BIPV) has Potential to generated electricity 802,344 MWh/Year or 3% to replace electricity supply from Grid/PLN and ROI 137 Years. In general, the NZEB potential is 47% to replace electricity supply from Grid/PLN.
IOP Conference Series: Earth and Environmental Science, 2019
This Research is focusing to design technical and financial viability of Net Zero Energy Building... more This Research is focusing to design technical and financial viability of Net Zero Energy Building (NZEB) from a study case of existing building in Jakarta, first by reduce Building’s energy consumption and employing renewable energy sources. The results showed that energy savings from implementing green building concept could reduce electricity usage by 18%and Return on Investment (ROI) 3.86 years, the utilization of the working scheme of the condenser pump to be used as a micro hydro power plant will generate Electric Power of 733.83 kW and have the potential to replace electricity supply from Grid/PLN by 26% and ROI 3.5 years, the installation of Building Integrated Photovoltaic (BIPV) has Potential to generated electricity 802,344 MWh/Year or 3% to replace electricity supply from Grid/PLN and ROI 137 Years. In general, the NZEB potential is 47% to replace electricity supply from Grid/PLN.
Project Management Journal, 2009
IOP Conference Series: Materials Science and Engineering, 2020
In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH ... more In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH (Council on tall building and urban habitat) in 2018 there are 85 buildings and those that are under construction are 26 buildings, Super tall buildings with a height above 300 meters are 4 buildings and proposed mega tall building with a height of more than 600 meters is 1 building. All these buildings have very large electrical loads. The percentage of electricity consumption in the building that is the object of research is 30-50% coming from the Ventilation & Air Condition (VAC) system, 20% - 30% lighting systems, 10% computers and the rest from other utilities. Several papers and journals discussing the simulation or feasibility study of micro-hydropower plants in high-rise buildings have not yet been discussed how to utilized kinetic energy from the working scheme of the water condenser pump in the VAC system. in general, the existing papers discuss how to utilized gravity potentia...
Journal of Physics: Conference Series, 2019
Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficien... more Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficiency Index (EEI) and Water Consumption Index (WCI). The purpose of this study was to determine how extent the implementation of green building principles in Office Buildings. The results show that the implementation of the Energy Management Concept could also made energy performance more efficient. After Implementing through Retrofitting of the Chiller System, Recycle Waste Water, Replacement of Conventional lamp to Energy Saving LED, and also Conduct Training as well as workshop to all employees and tenants so we can get the optimization of energy saving as well as the saving cost. Based on the comparing data before and after the implementation of Energy Management Concept, it is found that Energy Efficiency Index (EEI) decreased from 238.8 kWh/m2/year to 134,04 kWh/m2/year and the Water Consumption Index (WCI) from 50 liter/person/day to 27.18 Liter/person/day, the saving cost from elect...
Jurnal Bakti Masyarakat Indonesia
Konsep Bangunan hijau / Green Building yang sedang menjadi tren secara global apabila diterapkan ... more Konsep Bangunan hijau / Green Building yang sedang menjadi tren secara global apabila diterapkan makabukan saja akan memperkuat brand image dari bangunan itu sendiri tetapi juga bisa menghemat biayaoperasional pengelolaan gedung, Metode penelitian yang digunakan adalah kualitatif dan kuantitatif. Metodekualitatif dilakukan melalui wawancara dengan pengelola gedung dan kamimteam konsultan perencana dariFakultas Teknik Universitas Atmajaya, studi kepustakaan, observasi/pengamatan, dan dokumentasi.. dalamstudi kasus gedung sampoerna strategic square setelah melakukan pekerjaan retrofit sistem Ventilation AirCondition (VAC) dengan mengganti chiller, Recycle air buangan, penggantian lampu konvensional denganlampu Hemat Energi dan juga sosialisasi kepada seluruh karyawan dan penyewa, maka didapatkan penghematandari pembayaran tagihan listrik saja sebesar Rp 477.932.856,43 / bulan (18%) dan secara kasar akan kembalimodal selama 3,77 Tahun.
Jurnal TIARSIE
Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficien... more Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficiency Index (EEI) and Water Consumption Index (WCI). The Implementation Energy Management Concept in an office buildings of this study based on the management system model of continual improvement ISO 50001:2011. The purpose of this study was to determine the extent to which the implementation of green building principles in Office Buildings. This study took the case study in an office building in Jakarta Indonesia that has two towers, each tower has 32 floors and 3 basement floors. The method used is descriptive with respect to GREENSHIP Rating Tools for existing building which consists of six categories; Appropriate Site Development (ASD), Energy Efficiency & Conservation (EEC), Water Conservation (WAC), Material Resources & Cycle (MRC), Indoor Air Health & Comfort (IHC) and Building & Environments Management (BEM). The results show that implementation the Energy Management Concept could ...
Jurnal TIARSIE
Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficien... more Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficiency Index (EEI) and Water Consumption Index (WCI). The Implementation Energy Management Concept in an office buildings of this study based on the management system model of continual improvement ISO 50001:2011. The purpose of this study was to determine the extent to which the implementation of green building principles in Office Buildings. This study took the case study in an office building in Jakarta Indonesia that has two towers, each tower has 32 floors and 3 basement floors. The method used is descriptive with respect to GREENSHIP Rating Tools for existing building which consists of six categories; Appropriate Site Development (ASD), Energy Efficiency & Conservation (EEC), Water Conservation (WAC), Material Resources & Cycle (MRC), Indoor Air Health & Comfort (IHC) and Building & Environments Management (BEM). The results show that implementation the Energy Management Concept could ...
https://iopscience.iop.org/, 2019
Green Building Concept has become popular in Indonesia. The purpose of this study was to determin... more Green Building Concept has become popular in Indonesia. The purpose of this study was to determine the extent to which the implementation of green building principles in Office Buildings. Research Method using a GREENSHIP Rating Tools for existing building which consists of six categories; Appropriate Site Development (ASD), Energy Efficiency &
Conservation (EEC), Water Conservation (WAC), Material Resources & Cycle (MRC), Indoor
Air Health & Comfort (IHC) and Building & Environments Management (BEM). The results show that implementation the Green Building Concept could also made energy performance more efficient, after Implementing through Retrofitting of the Chiller System, Recycle Waste Water, Replacement of Conventional lamp to Energy Saving LED and also Training and Education to all employees and tenants. From comparing Data research before implementation of Green Building
concept in 2014 and after Implementation and retrofitting in 2017 & 2018, found that Savings Cost from electricity bill payments is IDR. 466,803,325.67/month (18%) and roughly will Break Event Point (BEP) for 3.86 Years and Energy Efficiency Index (EEI) from 238.8 kwh/m2/Years to 123.65 kwh/m2/Year
https://iopscience.iop.org/, 2019
This Research is focusing to design technical and financial viability of Net Zero Energy Building... more This Research is focusing to design technical and financial viability of Net Zero Energy Building (NZEB) from a study case of existing building in Jakarta, first by reduce Building's energy consumption and employing renewable energy sources. The results showed that energy savings from implementing green building concept could reduce electricity usage by 18%and Return on Investment (ROI) 3.86 years, the utilization of the working scheme of the condenser pump to be used as a micro hydro power plant will generate Electric Power of 733.83 kW and have the potential to replace electricity supply from Grid/PLN by 26% and ROI 3.5 years, the installation of Building Integrated Photovoltaic (BIPV) has Potential to generated electricity 802,344 MWh/Year or 3% to replace electricity supply from Grid/PLN and ROI 137 Years. In general, the NZEB potential is 47% to replace electricity supply from Grid/PLN. 1. Introduction At the current condition when the issue of energy security and environmental sustainability become a concern of many countries [1,2,3,4], buildings sector are important as they could create significant impacts on its. In Indonesia building sector consume of the primary energy almost 20% [5] This study aims to make designs for commercial buildings especially existing high-rise buildings to be as efficient as possible in energy use by retrofitting to reduce energy consumption and employing Renewable Energy Sources (RES) by utilizing the potential building heights and cooling water systems to be utilized as micro hydro plant and the application of Building Integrated Photovoltaic (BIPV) on roofs and building facades. This research uses the concept of the Net Zero Energy Building (NZEB) which has several definitions for example according European Union through Energy performance of buildings directive (EPBD) states that "nearly net zero energy buildings mean buildings with very high energy performance (very efficient) [3], the amount of energy required from the Grid is almost zero or very low than needed and can significantly generate energy from renewable energy sources (RES). The definition of NZEB can be found in various literatures [6,7,8,9]. The basic elements in definition of NZEB and their relationship are shown in figure.1. The basic elements are building system, energy grid and weighting system. In order to make a clear balance calculation for the net zero goal, a boundary need to be clarified for the building system with on-site renewable. Inside this boundary, building system consumes delivered energy, such as electricity, natural gas, from on-site renewable and energy grids, and output energy back to the grid when the REP (renewable energy power) system generates excess
• Visualisasi merupakan gambaran serangan dunia maya seperti yang sesungguhnya terjadi. Mulai dar... more • Visualisasi merupakan gambaran serangan dunia maya seperti yang sesungguhnya terjadi. Mulai dari pelaku dan target, metode yang di lakukan, asal negara mana yang melakukan serangan dan tujuan serangan. • Visualisasi bisa didasarkan pada data yang tidak terlihat, visualisasi ini menggunakan gambar sebagai sarana komunikasi utama, dan menyediakan cara untuk mempelajari sesuatu tentang data. • Dalam data visualisasi ada juga banyak jenis, termasuk grafik, peta, jaringan, animasi, dan infografis Gambar 12-2. Visualisasi yang menunjukkan dua keluarga malware, baris pertama milik keluarga Fakerean dan barisan kedua milik keluarga Dontovo.
Percobaan dalam desain dan kegunaan mengikuti variasi pada formula umum: peserta (evaluator dan p... more Percobaan dalam desain dan kegunaan mengikuti variasi pada formula umum: peserta (evaluator dan pengguna), prosedur evaluasi, dan pengaturan lingkungan dan sistem. Salah satu jenis percobaan adalah uji kegunaan, menyelesaikan tugas tertentu secara terkendali. Jenis percobaan lainnya mengharuskan pengguna merespons pertanyaan spesifik. Namun lain membandingkan desain alternatif, mungkin menggunakan pemodelan dan simulasi analitis. Dalam buku pegangan klasik tentang kegunaan, Usability Engineering, Jakob Nielsen merekomendasikan agar Anda melakukan uji coba selama fase ini, terutama jika diperlukan keterlibatan pengguna.
Teaching Documents by firma purbantoro
Conference Presentations by firma purbantoro
IOP Conf. Series: Materials Science and Engineering, 2020
In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH ... more In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH (Council on tall building and urban habitat) in 2018 there are 85 buildings and those that are under construction are 26 buildings, Super tall buildings with a height above 300 meters are 4 buildings and proposed mega tall building with a height of more than 600 meters is 1 building. All these buildings have very large electrical loads. The percentage of electricity consumption in the building that is the object of research is 30-50% coming from the Ventilation & Air Condition (VAC) system, 20%-30% lighting systems, 10% computers and the rest from other utilities. Several papers and journals discussing the simulation or feasibility study of micro-hydropower plants in high-rise buildings have not yet been discussed how to utilized kinetic energy from the working scheme of the water condenser pump in the VAC system. in general, the existing papers discuss how to utilized gravity potential energy through the working scheme of the building's clean water tank which is on the roof (rooftop) when distributing water which is not optimal because of the flow of water from the clean water system is not continuous or steady-state. Research Object by taking a case study of a high-rise building in Jakarta with a height of 157 meters. The data was taken from the report on utility use for the 2018 period in the building. From the simulation, the potential of water flow rate (Q) is 0.499 m3 / sec and the electrical power that can be generated (P) is 733.83 kW and this is a Micro-hydro Power Generation category. Economic analysis for building energy savings of Rp. 541,765,714.29 / month and finally roughly Return on Investment (ROI) can be achieved in 3 years and 6 months.
IOP conference series, Dec 1, 2019
This Research is focusing to design technical and financial viability of Net Zero Energy Building... more This Research is focusing to design technical and financial viability of Net Zero Energy Building (NZEB) from a study case of existing building in Jakarta, first by reduce Building's energy consumption and employing renewable energy sources. The results showed that energy savings from implementing green building concept could reduce electricity usage by 18%and Return on Investment (ROI) 3.86 years, the utilization of the working scheme of the condenser pump to be used as a micro hydro power plant will generate Electric Power of 733.83 kW and have the potential to replace electricity supply from Grid/PLN by 26% and ROI 3.5 years, the installation of Building Integrated Photovoltaic (BIPV) has Potential to generated electricity 802,344 MWh/Year or 3% to replace electricity supply from Grid/PLN and ROI 137 Years. In general, the NZEB potential is 47% to replace electricity supply from Grid/PLN.
IOP Conference Series: Earth and Environmental Science, 2019
This Research is focusing to design technical and financial viability of Net Zero Energy Building... more This Research is focusing to design technical and financial viability of Net Zero Energy Building (NZEB) from a study case of existing building in Jakarta, first by reduce Building’s energy consumption and employing renewable energy sources. The results showed that energy savings from implementing green building concept could reduce electricity usage by 18%and Return on Investment (ROI) 3.86 years, the utilization of the working scheme of the condenser pump to be used as a micro hydro power plant will generate Electric Power of 733.83 kW and have the potential to replace electricity supply from Grid/PLN by 26% and ROI 3.5 years, the installation of Building Integrated Photovoltaic (BIPV) has Potential to generated electricity 802,344 MWh/Year or 3% to replace electricity supply from Grid/PLN and ROI 137 Years. In general, the NZEB potential is 47% to replace electricity supply from Grid/PLN.
Project Management Journal, 2009
IOP Conference Series: Materials Science and Engineering, 2020
In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH ... more In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH (Council on tall building and urban habitat) in 2018 there are 85 buildings and those that are under construction are 26 buildings, Super tall buildings with a height above 300 meters are 4 buildings and proposed mega tall building with a height of more than 600 meters is 1 building. All these buildings have very large electrical loads. The percentage of electricity consumption in the building that is the object of research is 30-50% coming from the Ventilation & Air Condition (VAC) system, 20% - 30% lighting systems, 10% computers and the rest from other utilities. Several papers and journals discussing the simulation or feasibility study of micro-hydropower plants in high-rise buildings have not yet been discussed how to utilized kinetic energy from the working scheme of the water condenser pump in the VAC system. in general, the existing papers discuss how to utilized gravity potentia...
Journal of Physics: Conference Series, 2019
Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficien... more Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficiency Index (EEI) and Water Consumption Index (WCI). The purpose of this study was to determine how extent the implementation of green building principles in Office Buildings. The results show that the implementation of the Energy Management Concept could also made energy performance more efficient. After Implementing through Retrofitting of the Chiller System, Recycle Waste Water, Replacement of Conventional lamp to Energy Saving LED, and also Conduct Training as well as workshop to all employees and tenants so we can get the optimization of energy saving as well as the saving cost. Based on the comparing data before and after the implementation of Energy Management Concept, it is found that Energy Efficiency Index (EEI) decreased from 238.8 kWh/m2/year to 134,04 kWh/m2/year and the Water Consumption Index (WCI) from 50 liter/person/day to 27.18 Liter/person/day, the saving cost from elect...
Jurnal Bakti Masyarakat Indonesia
Konsep Bangunan hijau / Green Building yang sedang menjadi tren secara global apabila diterapkan ... more Konsep Bangunan hijau / Green Building yang sedang menjadi tren secara global apabila diterapkan makabukan saja akan memperkuat brand image dari bangunan itu sendiri tetapi juga bisa menghemat biayaoperasional pengelolaan gedung, Metode penelitian yang digunakan adalah kualitatif dan kuantitatif. Metodekualitatif dilakukan melalui wawancara dengan pengelola gedung dan kamimteam konsultan perencana dariFakultas Teknik Universitas Atmajaya, studi kepustakaan, observasi/pengamatan, dan dokumentasi.. dalamstudi kasus gedung sampoerna strategic square setelah melakukan pekerjaan retrofit sistem Ventilation AirCondition (VAC) dengan mengganti chiller, Recycle air buangan, penggantian lampu konvensional denganlampu Hemat Energi dan juga sosialisasi kepada seluruh karyawan dan penyewa, maka didapatkan penghematandari pembayaran tagihan listrik saja sebesar Rp 477.932.856,43 / bulan (18%) dan secara kasar akan kembalimodal selama 3,77 Tahun.
Jurnal TIARSIE
Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficien... more Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficiency Index (EEI) and Water Consumption Index (WCI). The Implementation Energy Management Concept in an office buildings of this study based on the management system model of continual improvement ISO 50001:2011. The purpose of this study was to determine the extent to which the implementation of green building principles in Office Buildings. This study took the case study in an office building in Jakarta Indonesia that has two towers, each tower has 32 floors and 3 basement floors. The method used is descriptive with respect to GREENSHIP Rating Tools for existing building which consists of six categories; Appropriate Site Development (ASD), Energy Efficiency & Conservation (EEC), Water Conservation (WAC), Material Resources & Cycle (MRC), Indoor Air Health & Comfort (IHC) and Building & Environments Management (BEM). The results show that implementation the Energy Management Concept could ...
Jurnal TIARSIE
Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficien... more Energy Management Concept as part of Green Building Concept is focused to Improve Energy Efficiency Index (EEI) and Water Consumption Index (WCI). The Implementation Energy Management Concept in an office buildings of this study based on the management system model of continual improvement ISO 50001:2011. The purpose of this study was to determine the extent to which the implementation of green building principles in Office Buildings. This study took the case study in an office building in Jakarta Indonesia that has two towers, each tower has 32 floors and 3 basement floors. The method used is descriptive with respect to GREENSHIP Rating Tools for existing building which consists of six categories; Appropriate Site Development (ASD), Energy Efficiency & Conservation (EEC), Water Conservation (WAC), Material Resources & Cycle (MRC), Indoor Air Health & Comfort (IHC) and Building & Environments Management (BEM). The results show that implementation the Energy Management Concept could ...
https://iopscience.iop.org/, 2019
Green Building Concept has become popular in Indonesia. The purpose of this study was to determin... more Green Building Concept has become popular in Indonesia. The purpose of this study was to determine the extent to which the implementation of green building principles in Office Buildings. Research Method using a GREENSHIP Rating Tools for existing building which consists of six categories; Appropriate Site Development (ASD), Energy Efficiency &
Conservation (EEC), Water Conservation (WAC), Material Resources & Cycle (MRC), Indoor
Air Health & Comfort (IHC) and Building & Environments Management (BEM). The results show that implementation the Green Building Concept could also made energy performance more efficient, after Implementing through Retrofitting of the Chiller System, Recycle Waste Water, Replacement of Conventional lamp to Energy Saving LED and also Training and Education to all employees and tenants. From comparing Data research before implementation of Green Building
concept in 2014 and after Implementation and retrofitting in 2017 & 2018, found that Savings Cost from electricity bill payments is IDR. 466,803,325.67/month (18%) and roughly will Break Event Point (BEP) for 3.86 Years and Energy Efficiency Index (EEI) from 238.8 kwh/m2/Years to 123.65 kwh/m2/Year
https://iopscience.iop.org/, 2019
This Research is focusing to design technical and financial viability of Net Zero Energy Building... more This Research is focusing to design technical and financial viability of Net Zero Energy Building (NZEB) from a study case of existing building in Jakarta, first by reduce Building's energy consumption and employing renewable energy sources. The results showed that energy savings from implementing green building concept could reduce electricity usage by 18%and Return on Investment (ROI) 3.86 years, the utilization of the working scheme of the condenser pump to be used as a micro hydro power plant will generate Electric Power of 733.83 kW and have the potential to replace electricity supply from Grid/PLN by 26% and ROI 3.5 years, the installation of Building Integrated Photovoltaic (BIPV) has Potential to generated electricity 802,344 MWh/Year or 3% to replace electricity supply from Grid/PLN and ROI 137 Years. In general, the NZEB potential is 47% to replace electricity supply from Grid/PLN. 1. Introduction At the current condition when the issue of energy security and environmental sustainability become a concern of many countries [1,2,3,4], buildings sector are important as they could create significant impacts on its. In Indonesia building sector consume of the primary energy almost 20% [5] This study aims to make designs for commercial buildings especially existing high-rise buildings to be as efficient as possible in energy use by retrofitting to reduce energy consumption and employing Renewable Energy Sources (RES) by utilizing the potential building heights and cooling water systems to be utilized as micro hydro plant and the application of Building Integrated Photovoltaic (BIPV) on roofs and building facades. This research uses the concept of the Net Zero Energy Building (NZEB) which has several definitions for example according European Union through Energy performance of buildings directive (EPBD) states that "nearly net zero energy buildings mean buildings with very high energy performance (very efficient) [3], the amount of energy required from the Grid is almost zero or very low than needed and can significantly generate energy from renewable energy sources (RES). The definition of NZEB can be found in various literatures [6,7,8,9]. The basic elements in definition of NZEB and their relationship are shown in figure.1. The basic elements are building system, energy grid and weighting system. In order to make a clear balance calculation for the net zero goal, a boundary need to be clarified for the building system with on-site renewable. Inside this boundary, building system consumes delivered energy, such as electricity, natural gas, from on-site renewable and energy grids, and output energy back to the grid when the REP (renewable energy power) system generates excess
• Visualisasi merupakan gambaran serangan dunia maya seperti yang sesungguhnya terjadi. Mulai dar... more • Visualisasi merupakan gambaran serangan dunia maya seperti yang sesungguhnya terjadi. Mulai dari pelaku dan target, metode yang di lakukan, asal negara mana yang melakukan serangan dan tujuan serangan. • Visualisasi bisa didasarkan pada data yang tidak terlihat, visualisasi ini menggunakan gambar sebagai sarana komunikasi utama, dan menyediakan cara untuk mempelajari sesuatu tentang data. • Dalam data visualisasi ada juga banyak jenis, termasuk grafik, peta, jaringan, animasi, dan infografis Gambar 12-2. Visualisasi yang menunjukkan dua keluarga malware, baris pertama milik keluarga Fakerean dan barisan kedua milik keluarga Dontovo.
Percobaan dalam desain dan kegunaan mengikuti variasi pada formula umum: peserta (evaluator dan p... more Percobaan dalam desain dan kegunaan mengikuti variasi pada formula umum: peserta (evaluator dan pengguna), prosedur evaluasi, dan pengaturan lingkungan dan sistem. Salah satu jenis percobaan adalah uji kegunaan, menyelesaikan tugas tertentu secara terkendali. Jenis percobaan lainnya mengharuskan pengguna merespons pertanyaan spesifik. Namun lain membandingkan desain alternatif, mungkin menggunakan pemodelan dan simulasi analitis. Dalam buku pegangan klasik tentang kegunaan, Usability Engineering, Jakob Nielsen merekomendasikan agar Anda melakukan uji coba selama fase ini, terutama jika diperlukan keterlibatan pengguna.
IOP Conf. Series: Materials Science and Engineering, 2020
In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH ... more In Indonesia the number of high-rise buildings above 150 m tends to increase, according to CTBUH (Council on tall building and urban habitat) in 2018 there are 85 buildings and those that are under construction are 26 buildings, Super tall buildings with a height above 300 meters are 4 buildings and proposed mega tall building with a height of more than 600 meters is 1 building. All these buildings have very large electrical loads. The percentage of electricity consumption in the building that is the object of research is 30-50% coming from the Ventilation & Air Condition (VAC) system, 20%-30% lighting systems, 10% computers and the rest from other utilities. Several papers and journals discussing the simulation or feasibility study of micro-hydropower plants in high-rise buildings have not yet been discussed how to utilized kinetic energy from the working scheme of the water condenser pump in the VAC system. in general, the existing papers discuss how to utilized gravity potential energy through the working scheme of the building's clean water tank which is on the roof (rooftop) when distributing water which is not optimal because of the flow of water from the clean water system is not continuous or steady-state. Research Object by taking a case study of a high-rise building in Jakarta with a height of 157 meters. The data was taken from the report on utility use for the 2018 period in the building. From the simulation, the potential of water flow rate (Q) is 0.499 m3 / sec and the electrical power that can be generated (P) is 733.83 kW and this is a Micro-hydro Power Generation category. Economic analysis for building energy savings of Rp. 541,765,714.29 / month and finally roughly Return on Investment (ROI) can be achieved in 3 years and 6 months.