mark baumert - Academia.edu (original) (raw)
Papers by mark baumert
MedChemComm, 2014
ABSTRACT A combination of conventional organic synthesis, remotely monitored flow synthesis and b... more ABSTRACT A combination of conventional organic synthesis, remotely monitored flow synthesis and bioassay platforms, were used for the evaluation of novel inhibitors targeting bromodomains outside the well-studied bromodomain and extra terminal (BET) family, here exemplified by activity measurements on the bromodomain of BRD9 protein, a component of some tissue-specific SWi/SNF chromatin remodelling complexes. The Frontal Affinity Chromatography combined with Mass Spectrometry (FAC-MS) method proved to be reliable and results correlated well with an independent thermal shift assay.
Analytical Chemistry, 2010
Rapid Communications in Mass Spectrometry, 2014
Non-covalent mass spectrometry (MS) offers considerable potential for protein-ligand screening in... more Non-covalent mass spectrometry (MS) offers considerable potential for protein-ligand screening in drug discovery programmes. However, there are some limitations with the time-of-flight (TOF) instrumentation typically employed that restrict the application of non-covalent MS in industrial laboratories. An Exactive Plus EMR mass spectrometer was investigated for its ability to characterise non-covalent protein-small molecule interactions. Nano-electrospray ionisation (nanoESI) infusion was achieved with a TriVersa NanoMate. The transport multipole and ion lens voltages, dissociation energies and pressure in the Orbitrap™ were optimised. Native MS was performed, with ligand titrations to judge retention of protein-ligand interactions, serial dilutions of native proteins as an indication of sensitivity, and a heterogeneous protein analysed for spectral resolution. Interactions between native proteins and ligands are preserved during analysis on the Exactive Plus EMR, with the binding affinities determined in good agreement with expected values. High spectral resolution allows baseline separation of adduct ions, which should improve the accuracy and limit of detection for measuring ligand interactions. Data are also presented showing baseline resolution of glycoforms of a highly glycosylated protein, allowing binding of a fragment molecule to be detected. The high sensitivity and spectral resolution achievable with the Orbitrap technology confer significant advantages over TOF mass spectrometers, and offer a solution to current limitations regarding throughput, data analysis and sample requirements. A further benefit of improved spectral resolution is the possibility of using heterogeneous protein samples such as glycoproteins for fragment screening. This would significantly expand the scope of applicability of non-covalent MS in the pharmaceutical and other industries.
Circulation Cardiovascular Genetics
by modifying GCH1 may regulate excessive NO production and therefore represent a novel therapeuti... more by modifying GCH1 may regulate excessive NO production and therefore represent a novel therapeutic target for the treatment of refractory hypotension in septic shock patients.
Rapid Communications in Mass Spectrometry, 2004
An assay method with mass spectrometric detection was developed for the quantitative analysis of ... more An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human plasma using chip-based infusion. Liquid-liquid extraction sample preparation was found to be essential to minimize matrix suppression and to achieve a limit of quantitation (LOQ) of 2.5 ng/mL using a 100 microL plasma aliquot. The potential for simultaneous quantitation in selected reaction monitoring (SRM), tandem mass spectrometry (MS/MS) (enhanced product ion), and MS(3) was investigated and found to be very beneficial in improving assay selectivity. A novel concept for monitoring quantitative assay performance using a SRM/MS(3) ratio is proposed.
Rapid Communications in Mass Spectrometry, 2014
The signal intensity of a given molecule across a tissue section when measured using mass spectro... more The signal intensity of a given molecule across a tissue section when measured using mass spectrometry imaging (MSI) is prone to changes caused by the molecular heterogeneity across the surface of the tissue. Here we propose a strategy to investigate these effects using electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) on a single high-resolution mass spectrometry (HRMS) platform. A rat was administered with a single inhaled dose of a compound and sacrificed 1 h after dosing. Sections were prepared from the excised frozen lung and analysed using MALDI, liquid extraction surface analysis (LESA) nano-ESI-MS and nano-ESI liquid chromatography (LC)/MS. The ESI and MALDI ion sources were mounted either side of the ion transfer system of the same Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. MALDI MSI clearly demonstrated widespread distribution of the dosed molecule throughout the lung, with the exception of a non-lung section of tissue on the same sample surface. Comparison of the lipid signals across the sample indicated a change in signal between the lung and the adipose tissue present on the same section. Use of ESI and MALDI, with and without an internal standard, supported the evaluation of changes in the signal of the dosed molecule across the tissue section. The results demonstrate the successful application of a dual ion source HRMS system to the systematic evaluation of data from MALDI MSI, used to determine the distribution of an inhaled drug in the lung. The system discussed is of great utility in investigating the effects of ion suppression and evaluating the quantitative and qualitative nature of the MSI data.
Journal of Mass Spectrometry, 2012
Top-down shotgun lipidomics relies on direct infusion of total lipid extracts into a high-resolut... more Top-down shotgun lipidomics relies on direct infusion of total lipid extracts into a high-resolution tandem mass spectrometer and implies that individual lipids are recognized by their accurately determined m/z. Lipid ionization efficiency and detection specificity strongly depend on the acquisition polarity, and therefore it is beneficial to analyze lipid mixtures in both positive and negative modes. Hybrid LTQ Orbitrap mass spectrometers are widely applied in top-down lipidomics; however, rapid polarity switching was previously unfeasible because of the severe and immediate degradation of mass accuracy. Here, we report on a method to rapidly acquire high-resolution spectra in both polarity modes with sub-ppm mass accuracy and demonstrate that it not only simplifies and accelerates shotgun lipidomics analyses but also improves the lipidome coverage because more lipid classes and more individual species within each class are recognized. In this way, shotgun analysis of total lipid extracts of human blood plasma enabled to quantify 222 species from 15 major lipid classes within 7 min acquisition cycle.
Analytical Chemistry, 2010
Analytical Chemistry, 2003
Nanoflow electrospray mass spectrometry has been applied previously to investigate noncovalent pr... more Nanoflow electrospray mass spectrometry has been applied previously to investigate noncovalent proteinprotein and protein-ligand interactions. Here we evaluate a commercial microchip device for this application. We show that the microchip can be used to obtain mass spectra of the noncovalent tetramer transthyretin. The device showed a 10-fold increase in signal stability compared with a nanoflow capillary and a high level of nozzle-to-nozzle reproducibility. Binding of the natural ligand thyroxine was clearly observed, and a range of small molecules proposed as inhibitors of transthyretin amyloidosis were shown to be effective in stabilizing the tetramer. We propose that measuring the ability of small molecules to stabilize protein complexes using this automated microchip technology will enable high-throughput screening of multi-protein complexes by mass spectrometry.
Analytical Chemistry, 2011
Hemoglobinopathies are the most common inherited disorders. Newborn blood screening for clinicall... more Hemoglobinopathies are the most common inherited disorders. Newborn blood screening for clinically significant hemoglobin variants, including sickle (HbS), HbC, and HbD, has been adopted in many countries as it is widely acknowledged that early detection improves the outcome. We present a method for determination of Hb variants by direct surface sampling of dried blood spots by use of an Advion Triversa Nanomate automated electrospray system coupled to a highresolution mass spectrometer. The method involves no sample preparation. It is possible to unambiguously identify homozygous and heterozygous HbS, HbC, and HbD variants in <10 min without the need for additional confirmation. The method allows for repeated analysis of a single blood spot over a prolonged time period and is tolerant of blood spot storage conditions.
MedChemComm, 2014
ABSTRACT A combination of conventional organic synthesis, remotely monitored flow synthesis and b... more ABSTRACT A combination of conventional organic synthesis, remotely monitored flow synthesis and bioassay platforms, were used for the evaluation of novel inhibitors targeting bromodomains outside the well-studied bromodomain and extra terminal (BET) family, here exemplified by activity measurements on the bromodomain of BRD9 protein, a component of some tissue-specific SWi/SNF chromatin remodelling complexes. The Frontal Affinity Chromatography combined with Mass Spectrometry (FAC-MS) method proved to be reliable and results correlated well with an independent thermal shift assay.
Analytical Chemistry, 2010
Rapid Communications in Mass Spectrometry, 2014
Non-covalent mass spectrometry (MS) offers considerable potential for protein-ligand screening in... more Non-covalent mass spectrometry (MS) offers considerable potential for protein-ligand screening in drug discovery programmes. However, there are some limitations with the time-of-flight (TOF) instrumentation typically employed that restrict the application of non-covalent MS in industrial laboratories. An Exactive Plus EMR mass spectrometer was investigated for its ability to characterise non-covalent protein-small molecule interactions. Nano-electrospray ionisation (nanoESI) infusion was achieved with a TriVersa NanoMate. The transport multipole and ion lens voltages, dissociation energies and pressure in the Orbitrap™ were optimised. Native MS was performed, with ligand titrations to judge retention of protein-ligand interactions, serial dilutions of native proteins as an indication of sensitivity, and a heterogeneous protein analysed for spectral resolution. Interactions between native proteins and ligands are preserved during analysis on the Exactive Plus EMR, with the binding affinities determined in good agreement with expected values. High spectral resolution allows baseline separation of adduct ions, which should improve the accuracy and limit of detection for measuring ligand interactions. Data are also presented showing baseline resolution of glycoforms of a highly glycosylated protein, allowing binding of a fragment molecule to be detected. The high sensitivity and spectral resolution achievable with the Orbitrap technology confer significant advantages over TOF mass spectrometers, and offer a solution to current limitations regarding throughput, data analysis and sample requirements. A further benefit of improved spectral resolution is the possibility of using heterogeneous protein samples such as glycoproteins for fragment screening. This would significantly expand the scope of applicability of non-covalent MS in the pharmaceutical and other industries.
Circulation Cardiovascular Genetics
by modifying GCH1 may regulate excessive NO production and therefore represent a novel therapeuti... more by modifying GCH1 may regulate excessive NO production and therefore represent a novel therapeutic target for the treatment of refractory hypotension in septic shock patients.
Rapid Communications in Mass Spectrometry, 2004
An assay method with mass spectrometric detection was developed for the quantitative analysis of ... more An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human plasma using chip-based infusion. Liquid-liquid extraction sample preparation was found to be essential to minimize matrix suppression and to achieve a limit of quantitation (LOQ) of 2.5 ng/mL using a 100 microL plasma aliquot. The potential for simultaneous quantitation in selected reaction monitoring (SRM), tandem mass spectrometry (MS/MS) (enhanced product ion), and MS(3) was investigated and found to be very beneficial in improving assay selectivity. A novel concept for monitoring quantitative assay performance using a SRM/MS(3) ratio is proposed.
Rapid Communications in Mass Spectrometry, 2014
The signal intensity of a given molecule across a tissue section when measured using mass spectro... more The signal intensity of a given molecule across a tissue section when measured using mass spectrometry imaging (MSI) is prone to changes caused by the molecular heterogeneity across the surface of the tissue. Here we propose a strategy to investigate these effects using electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) on a single high-resolution mass spectrometry (HRMS) platform. A rat was administered with a single inhaled dose of a compound and sacrificed 1 h after dosing. Sections were prepared from the excised frozen lung and analysed using MALDI, liquid extraction surface analysis (LESA) nano-ESI-MS and nano-ESI liquid chromatography (LC)/MS. The ESI and MALDI ion sources were mounted either side of the ion transfer system of the same Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. MALDI MSI clearly demonstrated widespread distribution of the dosed molecule throughout the lung, with the exception of a non-lung section of tissue on the same sample surface. Comparison of the lipid signals across the sample indicated a change in signal between the lung and the adipose tissue present on the same section. Use of ESI and MALDI, with and without an internal standard, supported the evaluation of changes in the signal of the dosed molecule across the tissue section. The results demonstrate the successful application of a dual ion source HRMS system to the systematic evaluation of data from MALDI MSI, used to determine the distribution of an inhaled drug in the lung. The system discussed is of great utility in investigating the effects of ion suppression and evaluating the quantitative and qualitative nature of the MSI data.
Journal of Mass Spectrometry, 2012
Top-down shotgun lipidomics relies on direct infusion of total lipid extracts into a high-resolut... more Top-down shotgun lipidomics relies on direct infusion of total lipid extracts into a high-resolution tandem mass spectrometer and implies that individual lipids are recognized by their accurately determined m/z. Lipid ionization efficiency and detection specificity strongly depend on the acquisition polarity, and therefore it is beneficial to analyze lipid mixtures in both positive and negative modes. Hybrid LTQ Orbitrap mass spectrometers are widely applied in top-down lipidomics; however, rapid polarity switching was previously unfeasible because of the severe and immediate degradation of mass accuracy. Here, we report on a method to rapidly acquire high-resolution spectra in both polarity modes with sub-ppm mass accuracy and demonstrate that it not only simplifies and accelerates shotgun lipidomics analyses but also improves the lipidome coverage because more lipid classes and more individual species within each class are recognized. In this way, shotgun analysis of total lipid extracts of human blood plasma enabled to quantify 222 species from 15 major lipid classes within 7 min acquisition cycle.
Analytical Chemistry, 2010
Analytical Chemistry, 2003
Nanoflow electrospray mass spectrometry has been applied previously to investigate noncovalent pr... more Nanoflow electrospray mass spectrometry has been applied previously to investigate noncovalent proteinprotein and protein-ligand interactions. Here we evaluate a commercial microchip device for this application. We show that the microchip can be used to obtain mass spectra of the noncovalent tetramer transthyretin. The device showed a 10-fold increase in signal stability compared with a nanoflow capillary and a high level of nozzle-to-nozzle reproducibility. Binding of the natural ligand thyroxine was clearly observed, and a range of small molecules proposed as inhibitors of transthyretin amyloidosis were shown to be effective in stabilizing the tetramer. We propose that measuring the ability of small molecules to stabilize protein complexes using this automated microchip technology will enable high-throughput screening of multi-protein complexes by mass spectrometry.
Analytical Chemistry, 2011
Hemoglobinopathies are the most common inherited disorders. Newborn blood screening for clinicall... more Hemoglobinopathies are the most common inherited disorders. Newborn blood screening for clinically significant hemoglobin variants, including sickle (HbS), HbC, and HbD, has been adopted in many countries as it is widely acknowledged that early detection improves the outcome. We present a method for determination of Hb variants by direct surface sampling of dried blood spots by use of an Advion Triversa Nanomate automated electrospray system coupled to a highresolution mass spectrometer. The method involves no sample preparation. It is possible to unambiguously identify homozygous and heterozygous HbS, HbC, and HbD variants in <10 min without the need for additional confirmation. The method allows for repeated analysis of a single blood spot over a prolonged time period and is tolerant of blood spot storage conditions.