Research paper thumbnail of Introduction to FC-TBSR based SVC for Voltage Regulation and Reactive Power Compensation

2016 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), 2016

This paper introduces operation and control of fixed capacitor thyristor binary switched reactor.... more This paper introduces operation and control of fixed capacitor thyristor binary switched reactor. The proposed system is used for Voltage Regulation and Reactive Power Compensation of the transmission system. It consists of reactor banks, arranged in binary order steps with fixed capacitor is referred as FC-TBSR. Normally we use SVC (TSC+TCR) for reactive power compensation and voltage regulation. But this type of SVC has some inherent drawbacks such as harmonics, more losses in TCR, SVC required the additional filter for harmonic reduction, the cost of SVC is more due additional Filter. To avoid these drawbacks a new FC-TBSR compensator has been proposed.

Research paper thumbnail of And Enhanced PLL Comparison of ReferenceCurrent Generation for Shunt Active Power Filter Using Goertzel Algorithm

In this paper the shunt active power filter using different reference current generation techniqu... more In this paper the shunt active power filter using different reference current generation techniques is compared. The reference current generation technique consists frequency domain method that uses Goertzel Algorithm. The second method used for comparison is Enhanced Phase Locked Loop (EPLL). The Goertzel Algorithm and Enhanced Phase Locked Loop are used to extract the fundamental component of load current. The extracted currents are used for generation of template currents for reference current generation. The shunt active power filter is implemented using these two methods and investigated for three phase balanced and unbalanced loads using MATLAB/Simulink. The methods are investigated for transient conditions, computations and the results are compared for effectiveness of the above methods under different conditions.

Research paper thumbnail of Sliding Mode Controller Implementation of Shunt Active Power Filter Using

In this paper control of shunt active power filter with sliding mode controller is considered. Th... more In this paper control of shunt active power filter with sliding mode controller is considered. The compensation by shunt active power filter involves harmonics mitigation due to three phase non linear loads. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynamic response of the system and provides faster convergence. The performance of the sliding mode controller is compared with the conventional PI controller. The realization of the system is implemented for balanced and unbalanced load conditions using MATLAB/Simulink. From the analysis it can be observed that the shunt active power filter with sliding mode controller gives a better response than the conventional PI controller. The simulation results prove the effectiveness of the proposed system. Power quality has become the point of concern with the increased use of non linear devices. The use of non linear devices has resulted into different po...

Research paper thumbnail of Error adaptive schemes for: LT and HT switched capacitors and microcontroller based static var compensator AT 11 kv substations

Research paper thumbnail of The Experimental Studies of Transient Free Digital SVC Controller with Thyristor Binary Compensator at 125 KVA Distribution Transformer I

Electrical distribution systems are incurring large losses as the loads are wide spread, inadequa... more Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. A comprehensive static VAR compensator consisting of capacitor bank in five binary sequential steps in conjunction with a thyristor controlled reactor of smallest step size is employed in the investigative work. The work deals with the performance evaluation through analytical studies and practical implementation on an existing system. A fast acting error adaptive controller is developed suitable both for contactor and thyristor switched capacitors. The switching operations achieved are transient free, practically no need to provide inrush current limiting reactors, TCR size minimum providing small percentages of nontriplen harmonics, facilitates stepless variation of reactive power depending on load requirement so as maintain power factor near unity always. It is elegant, closed loop microcontroller system having the ...

Research paper thumbnail of Goertzel Algorithm Based Shunt Active Power Filter Using Sliding Mode Controller

In this paper control of Goertzel Algorithm based shunt active power filter with sliding mode con... more In this paper control of Goertzel Algorithm based shunt active power filter with sliding mode controller is considered. Shunt active power filter involves harmonics mitigation due to three phase non linear loads under balanced and unbalanced load conditions. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynamic response of the system and provides faster convergence. The performance of the sliding mode controller is compared with the conventional PI controller. The above system is investigated for balanced and unbalanced load conditions using MATLAB/Simulink. From the analysis it can be observed that the Goertzel algorithm based shunt active power filter with sliding mode controller gives a better response than the conventional PI controller. The simulation results prove the effectiveness of the proposed system. Keywords—Shunt active power filter, total harmonic distortion,Goertzel Algorithm, slidin...

Research paper thumbnail of FC-TBSR Compensator for Reactive Power Compensation and Voltage Swell Mitigation

Lecture Notes in Electrical Engineering, 2020

This paper introduces FC-TBSR, which is one of the controllers in flexible AC transmission system... more This paper introduces FC-TBSR, which is one of the controllers in flexible AC transmission system. The thyristor binary switched reactor contains thyristors which are connected in antiparallel which acts as bidirectional switch in series with a reactor and fixed capacitor connected across. The reactor banks are arranged in binary steps. Usually, FACTS devices are used for voltage regulation and reactive power compensation but it has some drawbacks like harmonics injection and it will not give fine voltage control because it has fixed values. To avoid and overcome these drawbacks, a new FC-TBSR compensator has been proposed.

Research paper thumbnail of Performance up gradation of static VAR compensator with thyristor binary switched capacitor and reactor using model reference adaptive controller

Automatika, 2021

There are various static var compensator configurations are available and listed in the literatur... more There are various static var compensator configurations are available and listed in the literature. Their performances are evaluated based on their voltage support, dynamic response, losses, cost, and additional filter requirement, if any. In this paper, efforts are made to improve the dynamic performance parameter such as rise time, settling time, and peak overshoots. A new topology with an adaptive controller is presented, in which capacitor and reactor banks are divided in their binary values and connected in the shunt. Capacitor and reactor banks are operated by thyristorised switches. Both these banks are operated in closed-loop form as a cascade control. Amongst these, capacitor bank operates as coarse control, and reactor bank acts as fine control. For the performance enhancement, a model reference adaptive controller is used. The system identification toolbox is used to evaluate the mathematical model of the plant with Matlab. The model's performance was analyzed deeply by the adaptive controller with different reference models such as critical, under, and overdamped. The performance parameters such as rise time, settling time, and peak overshoot in the form of reactive power swings, are evaluated and plotted for different adaptive gains using MIT rules. Abbreviations: : Peak overshoot; : Reactive power of capacitor; : Reactive power of inductor; : Reactive power of TBSC bank; : Reactive power of TBSR bank; : Rise time; : Settling time; e: Error; Gc(s): Transfer function of TBSC plant; Gl(s): Transfer function of Disturbance plant; Gr(s): Transfer function of TBSR plant; SVC: Static VAR Compensator; t:time; TBSC: Thyristor binary switched capacitor; TBSR: Thyristor binary switched reactor; TSC: Thyristor switched capacitor; TSR: Thyristor switched reactor; u(t): System input; v(t): System disturbance; y(t): System output; Ym: Reference model output; Yp: Plant output; γ: Adaptive gain; θ: Theta

Research paper thumbnail of Reactive power compensation by TBSC compensator with eliminate harmonic resonance

2015 International Conference on Electrical, Electronics, Signals, Communication and Optimization (EESCO), 2015

Research paper thumbnail of Indigenous home remedies as applied in Shirpur Taluka of Dhule district (Maharashtra) India

The authors investigated Shirpur taluka of Dhule District (Maharashtra) for indigenous home remed... more The authors investigated Shirpur taluka of Dhule District (Maharashtra) for indigenous home remedies used to combat various human afflictions. Botanicals used in cuisine and commonly grown in homestead gardens are documented for their utilities especially against common afflictions. This paper includes information on 21 species belonging to 21 genera and 15 families of angiosperms. The medicinal recipes are in the form of decoction, infusion, extract, juice, oil, powder, paste and ash. Domestic substances are also added while preparing recipes. Raw parts or cooked ones are also employed in few cases. They are administered to benefit in about 17 different human afflictions. The medicines consist usually of sole drug, except few. Botanicals commonly used as spices, edibles and locally religious or ornamental ones also find place in the local remedies. Majority of them are under cultivation, while few others are purchased from markets. This paper highlights secondary applications of th...

Research paper thumbnail of Automatic tuning of PSS through FACTS by using genetic algorithm

This paper presents a systematic procedure for modelling and simulation of a power system install... more This paper presents a systematic procedure for modelling and simulation of a power system installed with a power system stabilizer (PSS) and a flexible AC transmission system (FACTS)-based controller. For the design purpose, the model of example power system which is a single-machine infinite-bus power system installed with the proposed controllers is developed in MATLAB/SIMULINK. In the developed model synchronous generator is represented by model 1.1. which includes both the generator main field winding and the damper winding in q-axis so as to evaluate the impact of PSS and FACTS-based controller on power system stability. Further, to avoid adverse interactions, PSS and FACTS-based controller are simultaneously designed employing genetic algorithm (GA). The non-linear simulation results are presented for the example power system under various disturbance conditions to validate the effectiveness of the proposed modeling and simultaneous design approach.

Research paper thumbnail of Model Reference Adaptive Technique for Sensorless Speed Control of Induction Motor

2008 First International Conference on Emerging Trends in Engineering and Technology, 2008

This paper describes a model reference adaptive system (MRAS) for speed control of the induction ... more This paper describes a model reference adaptive system (MRAS) for speed control of the induction motor drive (IM) without a speed sensor. In this scheme an adaptive pseudoreduced-order flux observer (APFO) is used instead of the adaptive full-order flux observer (AFFO), an APFO is used for estimate the IM rotor speed and stator resistance, and these are used as feedback

Research paper thumbnail of Performance Analysis of Different Current Controllers for Active Power Filter

Lecture Notes in Electrical Engineering, 2012

ABSTRACT Power Quality issues are becoming a major concern for today’s power system engineers. La... more ABSTRACT Power Quality issues are becoming a major concern for today’s power system engineers. Large scale incorporation of non-linear loads has the potential to raise harmonic voltages and currents in an electrical distribution system to unacceptable high levels that can adversely affect the system. Active power filter (APF) based on power electronic technology is currently considered as the most competitive equipment for mitigation of harmonics and reactive power simultaneously. Instantaneous power theory is used for generation of reference current. This paper presents a comparative study of the performance of three current control strategies namely ramp comparison method, hysteresis current controller (HCC) and Adaptive hysteresis current controller (AHCC) is carried out and superiority of AHCC is established. Simulation results for all the method are presented using MATLAB/SIMULINK power system toolbox demonstrating the effectiveness of using adaptive hysteresis band.

Research paper thumbnail of Comparison of reference current generation for shunt active power filter using Goertzel Algorithm and Enhanced PLL

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

In this paper the shunt active power filter using different reference current generation techniqu... more In this paper the shunt active power filter using different reference current generation techniques is compared. The reference current generation technique consists frequency domain method that uses Goertzel Algorithm. The second method used for comparison is Enhanced Phase Locked Loop (EPLL). The Goertzel Algorithm and Enhanced Phase Locked Loop are used to extract the fundamental component of load current. The extracted currents are used for generation of template currents for reference current generation. The shunt active power filter is implemented using these two methods and investigated for three phase balanced and unbalanced loads using MATLAB/Simulink. The methods are investigated for transient conditions, computations and the results are compared for effectiveness of the above methods under different conditions.

Research paper thumbnail of A novel technique for implementation of Shunt Active Power Filter under balanced and unbalanced load conditions

2013 International Conference on Circuits, Power and Computing Technologies (ICCPCT), 2013

ABSTRACT In this paper Enhanced Phase Locked Loop (EPLL) based Shunt Active Power Filter is discu... more ABSTRACT In this paper Enhanced Phase Locked Loop (EPLL) based Shunt Active Power Filter is discussed. The performance of EPLL based system is tested under balanced and unbalanced load conditions. The EPLL is used to extract the magnitude and phase of required frequency component from input signal. The method is used in shunt active power filters to eliminate harmonics, improve power factor and correct the unbalanced conditions. The EPLL based system is simulated for both three phase balanced and unbalanced load conditions using MATLAB/Simulink. The simulation results are presented to demonstrate the effectiveness of proposed system.

Research paper thumbnail of Implementation of shunt active power filter using sliding mode controller

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

ABSTRACT In this paper control of shunt active power filter with sliding mode controller is consi... more ABSTRACT In this paper control of shunt active power filter with sliding mode controller is considered. The compensation by shunt active power filter involves harmonics mitigation due to three phase non linear loads. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynamic response of the system and provides faster convergence. The performance of the sliding mode controller is compared with the conventional PI controller. The realization of the system is implemented for balanced and unbalanced load conditions using MATLAB/Simulink. From the analysis it can be observed that the shunt active power filter with sliding mode controller gives a better response than the conventional PI controller. The simulation results prove the effectiveness of the proposed system.

Research paper thumbnail of Voltage control of distribution system with PEM fuel cell interfaced with Z-source inverter

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

The fuel cells are considered as one of the most promising distributed energy resource due to its... more The fuel cells are considered as one of the most promising distributed energy resource due to its cleanliness, modularity and higher potential capability. Distributed energy resources (DER) interfaced with Z-source inverter (ZSI) using right control are capable of providing dynamic voltage regulation near the load end user. This paper presents Z-source inverter interfaced with proton exchange membrane fuel cell (PEMFC) connected to grid can boost DC voltage to supply voltage regulation dynamically, in particular with application of adaptive voltage control algorithm with double carrier pulse width modulation control. The simulation results in different system condition show that Z-Source inverter with PEMFC is capable of proving dynamic voltage regulation without using boost converter. Since this system has advantages over two stage conversion with boost converter and voltage source inverter as it reduces system cost and increases overall efficiency of system, it is very suited for utility application.

Research paper thumbnail of Adaptive voltage control using Z-source inverter interfaced with distributed energy resources

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

Distributed energy resources (DER) interfaced with Z-source inverter (ZSI) using right control ar... more Distributed energy resources (DER) interfaced with Z-source inverter (ZSI) using right control are capable of providing dynamic voltage regulation near the load end user. This paper presents Z-source inverter interfaced with DE (photovoltaic cell, fuel cell, etc.) connected to grid can boost DC voltage to supply voltage regulation dynamically, in particular with application of adaptive voltage control algorithm with double carrier pulse width modulation control. The simulation results in different system condition show that Z-Source inverter with DE is capable of proving dynamic voltage regulation without using boost converter. Since this system has advantages over voltage source inverter (VSI) interfaced with DE as it reduces system cost and increases overall efficiency of system, it is very suited for utility application.

Research paper thumbnail of Adaptive control schemes for distribution system with DER

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

ABSTRACT Reactive power is the key controller in voltage regulation system. Distributed Energy Re... more ABSTRACT Reactive power is the key controller in voltage regulation system. Distributed Energy Resources (DER) can be the solution to mitigate the voltage regulation problem with right control technique. DER can generate or consume reactive power with proper power electronics interface. It has also capacity to provide ancillary services. The new decentralize Adaptive technique has been implemented in this paper. Simulation results of adaptive method for different load condition satisfies the fast dynamic speed requirement without any oscillation and overshoot. In this paper the new methods for voltage regulation has been discussed which are Model Reference Adaptive System (MRAS), Direct and Indirect Self Tuning Regulator. These methods can solve the complex issue of voltage regulation in power system.

Research paper thumbnail of Performance of Series-Shunt Power Quality Compensator under unbalanced & distorted loading conditions

2013 IEEE International Conference on Control Applications (CCA), 2013

ABSTRACT Harmonically polluted environment of power system is the most severe problem and integra... more ABSTRACT Harmonically polluted environment of power system is the most severe problem and integrated day by day, due to vast development and use of the power electronic devices. So it is good practice to use power filter to improve the power quality by reducing the voltage or current harmonics. In this paper, the performance of the Series-Shunt Power Quality Compensator (S-SPQC) is presented under unbalanced and distorted system conditions. In this topology two type of active filters i.e. Series and shunt are integrated to accomplish the goal of improving voltage quality and current quality respectively. In combined approach of S-SPQC, Series part is designed by using Synchronous Reference Frame (SRF) technique while shunt part is designed by using Indirect Current Control (ICC) technique. The MATLAB/ Simulink based simulation results are graphically shown as well as tabulated in detail which reflects the performance of the S-SPQC control method discussed in this paper.

Research paper thumbnail of Introduction to FC-TBSR based SVC for Voltage Regulation and Reactive Power Compensation

2016 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), 2016

This paper introduces operation and control of fixed capacitor thyristor binary switched reactor.... more This paper introduces operation and control of fixed capacitor thyristor binary switched reactor. The proposed system is used for Voltage Regulation and Reactive Power Compensation of the transmission system. It consists of reactor banks, arranged in binary order steps with fixed capacitor is referred as FC-TBSR. Normally we use SVC (TSC+TCR) for reactive power compensation and voltage regulation. But this type of SVC has some inherent drawbacks such as harmonics, more losses in TCR, SVC required the additional filter for harmonic reduction, the cost of SVC is more due additional Filter. To avoid these drawbacks a new FC-TBSR compensator has been proposed.

Research paper thumbnail of And Enhanced PLL Comparison of ReferenceCurrent Generation for Shunt Active Power Filter Using Goertzel Algorithm

In this paper the shunt active power filter using different reference current generation techniqu... more In this paper the shunt active power filter using different reference current generation techniques is compared. The reference current generation technique consists frequency domain method that uses Goertzel Algorithm. The second method used for comparison is Enhanced Phase Locked Loop (EPLL). The Goertzel Algorithm and Enhanced Phase Locked Loop are used to extract the fundamental component of load current. The extracted currents are used for generation of template currents for reference current generation. The shunt active power filter is implemented using these two methods and investigated for three phase balanced and unbalanced loads using MATLAB/Simulink. The methods are investigated for transient conditions, computations and the results are compared for effectiveness of the above methods under different conditions.

Research paper thumbnail of Sliding Mode Controller Implementation of Shunt Active Power Filter Using

In this paper control of shunt active power filter with sliding mode controller is considered. Th... more In this paper control of shunt active power filter with sliding mode controller is considered. The compensation by shunt active power filter involves harmonics mitigation due to three phase non linear loads. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynamic response of the system and provides faster convergence. The performance of the sliding mode controller is compared with the conventional PI controller. The realization of the system is implemented for balanced and unbalanced load conditions using MATLAB/Simulink. From the analysis it can be observed that the shunt active power filter with sliding mode controller gives a better response than the conventional PI controller. The simulation results prove the effectiveness of the proposed system. Power quality has become the point of concern with the increased use of non linear devices. The use of non linear devices has resulted into different po...

Research paper thumbnail of Error adaptive schemes for: LT and HT switched capacitors and microcontroller based static var compensator AT 11 kv substations

Research paper thumbnail of The Experimental Studies of Transient Free Digital SVC Controller with Thyristor Binary Compensator at 125 KVA Distribution Transformer I

Electrical distribution systems are incurring large losses as the loads are wide spread, inadequa... more Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. A comprehensive static VAR compensator consisting of capacitor bank in five binary sequential steps in conjunction with a thyristor controlled reactor of smallest step size is employed in the investigative work. The work deals with the performance evaluation through analytical studies and practical implementation on an existing system. A fast acting error adaptive controller is developed suitable both for contactor and thyristor switched capacitors. The switching operations achieved are transient free, practically no need to provide inrush current limiting reactors, TCR size minimum providing small percentages of nontriplen harmonics, facilitates stepless variation of reactive power depending on load requirement so as maintain power factor near unity always. It is elegant, closed loop microcontroller system having the ...

Research paper thumbnail of Goertzel Algorithm Based Shunt Active Power Filter Using Sliding Mode Controller

In this paper control of Goertzel Algorithm based shunt active power filter with sliding mode con... more In this paper control of Goertzel Algorithm based shunt active power filter with sliding mode controller is considered. Shunt active power filter involves harmonics mitigation due to three phase non linear loads under balanced and unbalanced load conditions. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynamic response of the system and provides faster convergence. The performance of the sliding mode controller is compared with the conventional PI controller. The above system is investigated for balanced and unbalanced load conditions using MATLAB/Simulink. From the analysis it can be observed that the Goertzel algorithm based shunt active power filter with sliding mode controller gives a better response than the conventional PI controller. The simulation results prove the effectiveness of the proposed system. Keywords—Shunt active power filter, total harmonic distortion,Goertzel Algorithm, slidin...

Research paper thumbnail of FC-TBSR Compensator for Reactive Power Compensation and Voltage Swell Mitigation

Lecture Notes in Electrical Engineering, 2020

This paper introduces FC-TBSR, which is one of the controllers in flexible AC transmission system... more This paper introduces FC-TBSR, which is one of the controllers in flexible AC transmission system. The thyristor binary switched reactor contains thyristors which are connected in antiparallel which acts as bidirectional switch in series with a reactor and fixed capacitor connected across. The reactor banks are arranged in binary steps. Usually, FACTS devices are used for voltage regulation and reactive power compensation but it has some drawbacks like harmonics injection and it will not give fine voltage control because it has fixed values. To avoid and overcome these drawbacks, a new FC-TBSR compensator has been proposed.

Research paper thumbnail of Performance up gradation of static VAR compensator with thyristor binary switched capacitor and reactor using model reference adaptive controller

Automatika, 2021

There are various static var compensator configurations are available and listed in the literatur... more There are various static var compensator configurations are available and listed in the literature. Their performances are evaluated based on their voltage support, dynamic response, losses, cost, and additional filter requirement, if any. In this paper, efforts are made to improve the dynamic performance parameter such as rise time, settling time, and peak overshoots. A new topology with an adaptive controller is presented, in which capacitor and reactor banks are divided in their binary values and connected in the shunt. Capacitor and reactor banks are operated by thyristorised switches. Both these banks are operated in closed-loop form as a cascade control. Amongst these, capacitor bank operates as coarse control, and reactor bank acts as fine control. For the performance enhancement, a model reference adaptive controller is used. The system identification toolbox is used to evaluate the mathematical model of the plant with Matlab. The model's performance was analyzed deeply by the adaptive controller with different reference models such as critical, under, and overdamped. The performance parameters such as rise time, settling time, and peak overshoot in the form of reactive power swings, are evaluated and plotted for different adaptive gains using MIT rules. Abbreviations: : Peak overshoot; : Reactive power of capacitor; : Reactive power of inductor; : Reactive power of TBSC bank; : Reactive power of TBSR bank; : Rise time; : Settling time; e: Error; Gc(s): Transfer function of TBSC plant; Gl(s): Transfer function of Disturbance plant; Gr(s): Transfer function of TBSR plant; SVC: Static VAR Compensator; t:time; TBSC: Thyristor binary switched capacitor; TBSR: Thyristor binary switched reactor; TSC: Thyristor switched capacitor; TSR: Thyristor switched reactor; u(t): System input; v(t): System disturbance; y(t): System output; Ym: Reference model output; Yp: Plant output; γ: Adaptive gain; θ: Theta

Research paper thumbnail of Reactive power compensation by TBSC compensator with eliminate harmonic resonance

2015 International Conference on Electrical, Electronics, Signals, Communication and Optimization (EESCO), 2015

Research paper thumbnail of Indigenous home remedies as applied in Shirpur Taluka of Dhule district (Maharashtra) India

The authors investigated Shirpur taluka of Dhule District (Maharashtra) for indigenous home remed... more The authors investigated Shirpur taluka of Dhule District (Maharashtra) for indigenous home remedies used to combat various human afflictions. Botanicals used in cuisine and commonly grown in homestead gardens are documented for their utilities especially against common afflictions. This paper includes information on 21 species belonging to 21 genera and 15 families of angiosperms. The medicinal recipes are in the form of decoction, infusion, extract, juice, oil, powder, paste and ash. Domestic substances are also added while preparing recipes. Raw parts or cooked ones are also employed in few cases. They are administered to benefit in about 17 different human afflictions. The medicines consist usually of sole drug, except few. Botanicals commonly used as spices, edibles and locally religious or ornamental ones also find place in the local remedies. Majority of them are under cultivation, while few others are purchased from markets. This paper highlights secondary applications of th...

Research paper thumbnail of Automatic tuning of PSS through FACTS by using genetic algorithm

This paper presents a systematic procedure for modelling and simulation of a power system install... more This paper presents a systematic procedure for modelling and simulation of a power system installed with a power system stabilizer (PSS) and a flexible AC transmission system (FACTS)-based controller. For the design purpose, the model of example power system which is a single-machine infinite-bus power system installed with the proposed controllers is developed in MATLAB/SIMULINK. In the developed model synchronous generator is represented by model 1.1. which includes both the generator main field winding and the damper winding in q-axis so as to evaluate the impact of PSS and FACTS-based controller on power system stability. Further, to avoid adverse interactions, PSS and FACTS-based controller are simultaneously designed employing genetic algorithm (GA). The non-linear simulation results are presented for the example power system under various disturbance conditions to validate the effectiveness of the proposed modeling and simultaneous design approach.

Research paper thumbnail of Model Reference Adaptive Technique for Sensorless Speed Control of Induction Motor

2008 First International Conference on Emerging Trends in Engineering and Technology, 2008

This paper describes a model reference adaptive system (MRAS) for speed control of the induction ... more This paper describes a model reference adaptive system (MRAS) for speed control of the induction motor drive (IM) without a speed sensor. In this scheme an adaptive pseudoreduced-order flux observer (APFO) is used instead of the adaptive full-order flux observer (AFFO), an APFO is used for estimate the IM rotor speed and stator resistance, and these are used as feedback

Research paper thumbnail of Performance Analysis of Different Current Controllers for Active Power Filter

Lecture Notes in Electrical Engineering, 2012

ABSTRACT Power Quality issues are becoming a major concern for today’s power system engineers. La... more ABSTRACT Power Quality issues are becoming a major concern for today’s power system engineers. Large scale incorporation of non-linear loads has the potential to raise harmonic voltages and currents in an electrical distribution system to unacceptable high levels that can adversely affect the system. Active power filter (APF) based on power electronic technology is currently considered as the most competitive equipment for mitigation of harmonics and reactive power simultaneously. Instantaneous power theory is used for generation of reference current. This paper presents a comparative study of the performance of three current control strategies namely ramp comparison method, hysteresis current controller (HCC) and Adaptive hysteresis current controller (AHCC) is carried out and superiority of AHCC is established. Simulation results for all the method are presented using MATLAB/SIMULINK power system toolbox demonstrating the effectiveness of using adaptive hysteresis band.

Research paper thumbnail of Comparison of reference current generation for shunt active power filter using Goertzel Algorithm and Enhanced PLL

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

In this paper the shunt active power filter using different reference current generation techniqu... more In this paper the shunt active power filter using different reference current generation techniques is compared. The reference current generation technique consists frequency domain method that uses Goertzel Algorithm. The second method used for comparison is Enhanced Phase Locked Loop (EPLL). The Goertzel Algorithm and Enhanced Phase Locked Loop are used to extract the fundamental component of load current. The extracted currents are used for generation of template currents for reference current generation. The shunt active power filter is implemented using these two methods and investigated for three phase balanced and unbalanced loads using MATLAB/Simulink. The methods are investigated for transient conditions, computations and the results are compared for effectiveness of the above methods under different conditions.

Research paper thumbnail of A novel technique for implementation of Shunt Active Power Filter under balanced and unbalanced load conditions

2013 International Conference on Circuits, Power and Computing Technologies (ICCPCT), 2013

ABSTRACT In this paper Enhanced Phase Locked Loop (EPLL) based Shunt Active Power Filter is discu... more ABSTRACT In this paper Enhanced Phase Locked Loop (EPLL) based Shunt Active Power Filter is discussed. The performance of EPLL based system is tested under balanced and unbalanced load conditions. The EPLL is used to extract the magnitude and phase of required frequency component from input signal. The method is used in shunt active power filters to eliminate harmonics, improve power factor and correct the unbalanced conditions. The EPLL based system is simulated for both three phase balanced and unbalanced load conditions using MATLAB/Simulink. The simulation results are presented to demonstrate the effectiveness of proposed system.

Research paper thumbnail of Implementation of shunt active power filter using sliding mode controller

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

ABSTRACT In this paper control of shunt active power filter with sliding mode controller is consi... more ABSTRACT In this paper control of shunt active power filter with sliding mode controller is considered. The compensation by shunt active power filter involves harmonics mitigation due to three phase non linear loads. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynamic response of the system and provides faster convergence. The performance of the sliding mode controller is compared with the conventional PI controller. The realization of the system is implemented for balanced and unbalanced load conditions using MATLAB/Simulink. From the analysis it can be observed that the shunt active power filter with sliding mode controller gives a better response than the conventional PI controller. The simulation results prove the effectiveness of the proposed system.

Research paper thumbnail of Voltage control of distribution system with PEM fuel cell interfaced with Z-source inverter

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

The fuel cells are considered as one of the most promising distributed energy resource due to its... more The fuel cells are considered as one of the most promising distributed energy resource due to its cleanliness, modularity and higher potential capability. Distributed energy resources (DER) interfaced with Z-source inverter (ZSI) using right control are capable of providing dynamic voltage regulation near the load end user. This paper presents Z-source inverter interfaced with proton exchange membrane fuel cell (PEMFC) connected to grid can boost DC voltage to supply voltage regulation dynamically, in particular with application of adaptive voltage control algorithm with double carrier pulse width modulation control. The simulation results in different system condition show that Z-Source inverter with PEMFC is capable of proving dynamic voltage regulation without using boost converter. Since this system has advantages over two stage conversion with boost converter and voltage source inverter as it reduces system cost and increases overall efficiency of system, it is very suited for utility application.

Research paper thumbnail of Adaptive voltage control using Z-source inverter interfaced with distributed energy resources

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

Distributed energy resources (DER) interfaced with Z-source inverter (ZSI) using right control ar... more Distributed energy resources (DER) interfaced with Z-source inverter (ZSI) using right control are capable of providing dynamic voltage regulation near the load end user. This paper presents Z-source inverter interfaced with DE (photovoltaic cell, fuel cell, etc.) connected to grid can boost DC voltage to supply voltage regulation dynamically, in particular with application of adaptive voltage control algorithm with double carrier pulse width modulation control. The simulation results in different system condition show that Z-Source inverter with DE is capable of proving dynamic voltage regulation without using boost converter. Since this system has advantages over voltage source inverter (VSI) interfaced with DE as it reduces system cost and increases overall efficiency of system, it is very suited for utility application.

Research paper thumbnail of Adaptive control schemes for distribution system with DER

2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014

ABSTRACT Reactive power is the key controller in voltage regulation system. Distributed Energy Re... more ABSTRACT Reactive power is the key controller in voltage regulation system. Distributed Energy Resources (DER) can be the solution to mitigate the voltage regulation problem with right control technique. DER can generate or consume reactive power with proper power electronics interface. It has also capacity to provide ancillary services. The new decentralize Adaptive technique has been implemented in this paper. Simulation results of adaptive method for different load condition satisfies the fast dynamic speed requirement without any oscillation and overshoot. In this paper the new methods for voltage regulation has been discussed which are Model Reference Adaptive System (MRAS), Direct and Indirect Self Tuning Regulator. These methods can solve the complex issue of voltage regulation in power system.

Research paper thumbnail of Performance of Series-Shunt Power Quality Compensator under unbalanced & distorted loading conditions

2013 IEEE International Conference on Control Applications (CCA), 2013

ABSTRACT Harmonically polluted environment of power system is the most severe problem and integra... more ABSTRACT Harmonically polluted environment of power system is the most severe problem and integrated day by day, due to vast development and use of the power electronic devices. So it is good practice to use power filter to improve the power quality by reducing the voltage or current harmonics. In this paper, the performance of the Series-Shunt Power Quality Compensator (S-SPQC) is presented under unbalanced and distorted system conditions. In this topology two type of active filters i.e. Series and shunt are integrated to accomplish the goal of improving voltage quality and current quality respectively. In combined approach of S-SPQC, Series part is designed by using Synchronous Reference Frame (SRF) technique while shunt part is designed by using Indirect Current Control (ICC) technique. The MATLAB/ Simulink based simulation results are graphically shown as well as tabulated in detail which reflects the performance of the S-SPQC control method discussed in this paper.