Management of epistaxis in patients with ventricular assist device: a retrospective review (original) (raw)
- Original research article
- Open access
- Published: 02 August 2018
- Ralph Abi-Hachem1 &
- David Woojin Jang1
Journal of Otolaryngology - Head & Neck Surgery volume 47, Article number: 48 (2018)Cite this article
- 3039 Accesses
- 3 Citations
- Metrics details
Abstract
Background
Patients with a ventricular assist device (VAD) are at risk for epistaxis due to the need for anticoagulation. Additionally, these patients develop acquired von Willebrand syndrome (AvWS) due to these devices. Management is complicated by the risk of thrombosis if anticoagulation is reversed. This study sought to characterize the clinical features and management of epistaxis in this high-risk population.
Methods
Retrospective review of adults with VAD and epistaxis necessitating inpatient consultation with the otolaryngology service were included.
Results
49 patients met inclusion criteria**.** All patients had a presumed diagnosis of AvWS. An elevated INR (> 2.0) was present in 18 patients (36.7%). Anticoagulation was held in 14 (28.6%) patients, though active correction was not necessary. Multiple encounters were required in 16 (32.7%) patients. Spontaneous epistaxis was associated with multiple encounters (p = 0.02). The use of hemostatic material was associated with a lower likelihood of bleeding recurrence (p = 0.05), whereas cauterization with silver nitrate alone was associated with a higher likelihood of re-intervention (p = 0.05). Surgery or embolization was not required urgently for any patient. Endoscopy under general anesthesia was performed for one patient electively. Mean follow up time was 16.6 months (σ = 6.3). At six months, 18 (36.7%) patients were deceased.
Conclusion
While these patients are at risk for recurrent spontaneous epistaxis, nonsurgical treatment without active correction of INR or AvWS was largely successful. Placement of hemostatic material, as opposed to cautery with silver nitrate, should be considered as a first-line treatment in this group. Multidisciplinary collaboration is critical for successful management.
Background
Epistaxis remains the most frequent otolaryngologic emergency and the second most common reason for referral to an otolaryngologist [1]. Over the years, many studies have sought to develop algorithms for treatment and prevention. Despite this, management of epistaxis remains a controversial and evolving topic. For example, there are no standard guidelines on duration of nasal packing and whether prophylactic antibiotics are necessary [2]. More recently, the advent of endoscopic sphenopalatine artery ligation (ESPAL) and vascular interventional procedures raises the question of when such interventions should be pursued [3].
Epistaxis in the setting of coagulopathy is difficult to manage, as patients often require management of systemic coagulopathy in addition to intranasal interventions. Regardless of whether patients are medically anticoagulated or suffer from an acquired or hereditary coagulopathy, they have longer average inpatient hospital stays and require more invasive measures of local hemorrhage control when they develop epistaxis [[4](/articles/10.1186/s40463-018-0295-6#ref-CR4 "Smith J, Kim D, Dyer C, Siddiq S. Epistaxis in patients taking oral anticoagulant and antiplatelet medication: prospective cohort study. J Laryngol Otol. 2011 Jan;125(1):38–42. https://doi.org/10.1017/S0022215110001921
.")\]. The incidence is high, with 10–17% of patients developing epistaxis during long-term vitamin K antagonist therapy \[[5](/articles/10.1186/s40463-018-0295-6#ref-CR5 "Rubboli A, Becattini C, Verheugt FWA. Incidence, clinical impact and risk of bleeding during oral anticoagulation therapy. World J Cardiol. 2011 Nov 26;3(11):351–8.
https://doi.org/10.4330/wjc.v3.i11.351
.")\]. Given that there are 2.83 million quarterly visits with anticoagulation use in the United States, the at-risk population is significant \[[5](#ref-CR5 "Rubboli A, Becattini C, Verheugt FWA. Incidence, clinical impact and risk of bleeding during oral anticoagulation therapy. World J Cardiol. 2011 Nov 26;3(11):351–8.
https://doi.org/10.4330/wjc.v3.i11.351
."),[6](#ref-CR6 "Kirley K, Qato DM, Kornfield R, Stafford RS, Alexander GC. National trends in oral anticoagulant use in the United States, 2007 to 2011."),[7](/articles/10.1186/s40463-018-0295-6#ref-CR7 "Barnes GD, Lucas E, Alexander GC, Goldberger ZD. National Trends in Ambulator Oral Anticoagulant Use. Am J Med. 2015 Dec;128(12):1300–5.e2. doi:
https://doi.org/10.1016/j.amjmed.2015.05.044
.")\].
One patient population that is especially at risk for epistaxis are those with ventricular assist devices (VAD). Patients with heart failure may receive a VAD as either a bridge to transplantation or as destination therapy. They often require multiple anti-coagulant and anti-platelet medications, with a goal international normalized ratio (INR) of 2.5 [[8](/articles/10.1186/s40463-018-0295-6#ref-CR8 "Rossi M, Serraina GF, Jiritano F, Renzuli A. What is the optimal anticoagulation in patients with a left ventricular assist device? Interact Cardiovasc Thorac Surg. 2012 Oct;15(4):733–40. https://doi.org/10.1093/icvts/ivs297
.")\]. While bleeding is a major risk in these patients, sub-therapeutic levels can lead to devastating thromboembolic consequences, with a reported incidence of 2–47% \[[9](/articles/10.1186/s40463-018-0295-6#ref-CR9 "Van den Bergh WM, Lanskin-Hartgring AO, Van Duijin AL, Engström AE, Lahpor JR, Slooter AJC. Thromboembolic stroke in patients with a HeartMate –II left ventricular assist device – the role of anticoagulation. J Cardiothorac Surg. 2015;10:128.
https://doi.org/10.1186/s13019-015-0333-7
.")\]. Therefore, a delicate balance must be maintained. To make matters more complex, virtually all of these patients develop acquired von Willebrand syndrome (AvWS) as a result of the device itself. Patients with VAD are also poor surgical candidates due to their cardiac co-morbidities. All of the above factors create a complex situation when such a patient develops epistaxis.
Patients may develop von Willebrand disease (VWD) from a variety of etiologies, including hereditary and acquired origins. Given that VWD the most common hereditary blood-clotting disorder, its incidence is only increased by the multiple medical conditions that contribute to its development. On the most basic level, a deficiency in either the quantity or quality of von Willebrand factor (vWF) results in impaired platelet adhesion, and even in the mildest subtypes, epistaxis is a frequent symptom.
To our knowledge, this study would be the first to describe patient characteristics and management of epistaxis in this unique and complex patient population. We aimed to determine the efficacy of current treatment modalities as well as to identify risk factors for recurrence of epistaxis. Based on the findings of Smith et. Al [[4](/articles/10.1186/s40463-018-0295-6#ref-CR4 "Smith J, Kim D, Dyer C, Siddiq S. Epistaxis in patients taking oral anticoagulant and antiplatelet medication: prospective cohort study. J Laryngol Otol. 2011 Jan;125(1):38–42. https://doi.org/10.1017/S0022215110001921
.")\], we hypothesized that patients with VAD would be more likely to require aggressive measures such as operative intervention.
Methods
This is a retrospective review of adult patients (age greater than 18 years old) with an LVAD who required inpatient consultation with the otolaryngology service at Duke University Medical Center for epistaxis between July 1, 2006 and July 1, 2016. Institutional review board approval was obtained through Duke University. Patients were identified through the Duke Enterprise Data Unified Content Explorer (DEDUCE). All patients with LVAD were initially selected based on CPT code 0048 T or ICD codes V43.21 and Z95.811. From this group, those with a documented diagnosis of epistaxis (ICD codes 784.7 or R04.0) and associated otolaryngology inpatient consultation were selected.
Electronic medical records for these patients were then reviewed. Demographic information was recorded as well as information related to the LVAD (LVAD type, date of LVAD surgery). Furthermore, anticoagulant and antiplatelet medications, as well as vital signs and lab values at the time of consultation were extracted. Epistaxis was categorized as spontaneous versus traumatic. Additionally, the bleeding location, interventions performed, outpatient follow-up after discharge, and the outcomes of each intervention were extracted.
Statistical analysis
Data were grouped categorically and analyzed with Pearson’s chi-squared test. Tests of independence assessed for correlations between data points. Statistical analyses were performed with SPSS 23.0 software (SPSS Inc., Chicago, IL), with P < 0.05 considered significant.
Results
A total of 49 patients met the inclusion criteria, with 37 male and 12 female patients. Median age was 58 years (range: 18–85 years). The types of LVAD included 39 (79%) HeartMate II (HMII), seven HeartWare (14%), two Centimag (4%), and one VentrAssist (2%). The median time between LVAD placement and consultation for epistaxis was 46 days (range 2–2886). There were 15 (30%) patients who required consultation within 10 days of placement. Primary reasons for admission included cardiac symptoms (79.6%), epistaxis (12.2%), and other (8.2%). Forty-six patients were seen in an inpatient unit and three patients were seen in the emergency room.
Spontaneous non-traumatic bleeds occurred in 37 (75.5%) patients. The presence of spontaneous epistaxis was associated with multiple interventions (Chi-square = 5.345, _p_-value = 0.02). The most common site of bleeding was the anterior septum, with 31 (63.2%) patients bleeding from the unilateral septum, and 10 (20.4%) from the bilateral anterior septum (Fig. 1). Sixteen (32.7%) patients required multiple interventions from the otolaryngology service. Age, gender, and VAD type did not correlate significantly with spontaneous bleeding or the need for multiple interventions. Bleed location and the time between LVAD surgery and consultation did not correlate with spontaneous bleeding or need for multiple interventions. Mean follow-up time after initial consultation was 16.6 (σ = 6.3) months. 18 (36.7%) patients died prior to six month follow-up due to various causes, none of which were directly attributed to epistaxis. These findings are summarized in Table 1.
Fig. 1
Bleeding Location: Distribution of bleeding locations by number and percentage. Note that sites are not mutually exclusive
Table 1 Patient and Epistaxis Characteristics
Each subject had an average of 1.59 (σ = 1.09) encounters. Interventions included use of oxymetazoline spray with application of direct pressure as an initial measure in all patients. Cauterization with silver nitrate was performed in 35 (71.4%) patients. The use of cautery alone was associated with a need for repeat interventions (Chi-square = 3.998, _p-_value 0.05). Dissolvable hemostatic material was used in 23 (46.9%) patients, with Surgicel (Ethicon, NJ, USA) used in 7 (14.3%) patients, and Nasopore (Stryker, MI, USA) used in 17 (34.7%) patients. Hemospore, which contains chitosan lactate, was not utilized. Non-dissolvable packing was used in 14 (28.6%) patients, with 8 (16.3%) patients receiving Merocel (Medtronic, MN, USA) and 7 (14.3%) receiving Rapid Rhino (ArthroCare, TX, USA). The use of dissolvable or non-dissolvable hemostatic material was associated with a lower likelihood of bleeding recurrence (Chi-square = 4.204, _p_-value = 0.04), however this effect was not significant when assessing either dissolvable and non-dissolvable packing alone. Conservative, or non-surgical, therapy was successful in all patients. There was a single patient who was taken to the operating room for an elective lysis of synechiae that had resulted from prior interventions, requiring general anesthesia secondary to the amount of scarring and prior failure of bedside attempts. Dissolvable packing was placed in the nose at the conclusion of the procedure. No patient required urgent operative intervention or angiography with embolization (Fig. 2).
Fig. 2
Summary of Interventions: Distribution of interventions performed by number and percentage. Note that interventions are not mutually exclusive
All patients had an a priori diagnosis of AvWS as a result of the LVAD. Thirty-four patients (69.4%) were concurrently on warfarin, but only 18 (36.7%) of these had a therapeutic INR (between 2.0 and 3.0) at the time of epistaxis and only 4 (8.2%) had a supratherapeutic INR (greater than 3.0). Twenty-one (42.9%) patients were concurrently on heparin with 12 (24.5%) of these having prolonged partial thromboplastin time (greater than 40 s). Thirty-three (67.3%) patients were taking aspirin. Anticoagulant and antiplatelet medications were held in 14 (28.6%) patients because of epistaxis. Twenty-seven (55.1%) patients had normal platelet numbers (greater than 150,000) and 7 (14.3%) patients had platelet counts less than 100,000. No patient required active correction of anticoagulation with fresh frozen plasma, vitamin K, or protamine sulfate. There was no association between spontaneous bleeding or need for multiple interventions and the PTT, INR, or platelet count.
Discussion
This study is the first to describe epistaxis management in patients with LVAD. Patients with LVAD represent a complex patient population due to the need for continuous anticoagulation and the development of AvWS. Moreover, these patients have end-stage heart failure and are poor candidates for general anesthesia.
In several ways, our results are consistent with the existing literature. The majority (75.5%) of our patients had spontaneous, non-traumatic epistaxis. This is consistent with the findings by Parajuli [[10](/articles/10.1186/s40463-018-0295-6#ref-CR10 "Parajuli R. Evaluation of etiology and treatment methods for epistaxis: a review at a tertiary Care Hospital in Central Nepal. Int J Otolaryngol. 2015; https://doi.org/10.1155/2015/283854
.")\], who noted that 80–90% of general epistaxis patients had no identifiable cause. Also, 83.6% of episodes reported in our study occurred at the anterior nasal septum. This is consistent with the distribution seen in the general population, with literature reports of 80–90% of bleeds occurring at this location \[[1](/articles/10.1186/s40463-018-0295-6#ref-CR1 "Anghel AG, Soreanu CC, Dumitru M, Anghel I. Treatment options for severe epistaxis, the experience of the Coltea ENT clinic. Maedica (Buchar). 2014 Jun;9(2):179–82."), [11](/articles/10.1186/s40463-018-0295-6#ref-CR11 "Rudmik L, Smith TL. Management of intractable spontaneous epistaxis. Am J Rhinol Allergy. 2012 Jan-Feb;26(1):55–60.
https://doi.org/10.2500/ajra.2012.26.3696
.")\]. Moreover, the presence of spontaneous epistaxis in our patients was associated with multiple interventions (_P_ \= 0.02), with 32.7% requiring multiple interventions. Similarly, Anghel et. Al \[[1](/articles/10.1186/s40463-018-0295-6#ref-CR1 "Anghel AG, Soreanu CC, Dumitru M, Anghel I. Treatment options for severe epistaxis, the experience of the Coltea ENT clinic. Maedica (Buchar). 2014 Jun;9(2):179–82.")\] noted that patients with an idiopathic cause had the highest rate of recurrence over two years (26%). As for interventions, local cauterization with silver nitrate was performed in the majority of LVAD patients (71.4%). However, those undergoing cauterization alone without placement of hemostatic material were likely to require additional interventions at a later date. In their systematic review, Spielmann et al. noted that cautery was typically ineffective in patients receiving antiplatelet therapy \[[3](/articles/10.1186/s40463-018-0295-6#ref-CR3 "Spielmann PM, Barnes ML, White PS. Controversies in the specialist management of adult epistaxis: an evidence-based review. Clin Otolaryngol. 2012 Oct;37(5):382–9. Doi: 10.111/coa.12024.")\].
In our study, the use of hemostatic material, both absorbable and non-absorbable, was associated with a lower likelihood of bleeding recurrence. However, there was no difference in efficacy amongst the type of material placed. This is consistent with existing literature demonstrating no significant difference in efficacy of various types of nasal packing [12, [13](/articles/10.1186/s40463-018-0295-6#ref-CR13 "Wang J, Cai C, Wang S. Merocel versus Nasopore for nasal packing: a meta-analysis of randomized controlled trials. PLoS One. 2014 Apr 7;9(4):e93959. https://doi.org/10.1371/journal.pone.0093959
.")\]. Moreover, there were no adverse events related to nasal packing in our study. Based on these findings, hemostatic material should be considered as initial management in patients with LVAD who present with epistaxis.
Recently, ESPAL has been shown to be associated with a reduction in cost and length of hospitalization in comparison to non-surgical treatment [14,[15](#ref-CR15 "Zou Y, Deng YQ, Xia CW, Kong YG, Xu Y, Tao ZZ, Chen SM. Comparison of outcomes between endoscopic surgery and conventional nasal packing for epistaxis fornix of the inferior nasal meatus. Pak J Med Sci. 2015 Nov-Dec;31(6):1361–5. Doi: https://doi.org/10.12669/pjms.316.8340
."),[16](#ref-CR16 "Rudmik L, Leung R. Cost-effectiveness analysis of endoscopic sphenopalatine artery ligation vs arterial embolization for intractable epistaxis. JAMA Otolaryngol Head Neck Surg. 2014;140(9):802–8.
https://doi.org/10.1001/jamaoto.2014.1450
."),[17](/articles/10.1186/s40463-018-0295-6#ref-CR17 "Liu J, Zhong G, Wang Y. A retrospective analysis of 163 cases with intractable epistaxis managed by nasal endoscopic surgery. Lin Chung Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2013 Jun;27(11):590–2. Chinese.")\]. However, ESPAL should be considered carefully in patients with LVAD, given the high cardiac risks with general anesthesia and the bleeding risk from the surgery itself. For example, HeartMate II (HMII) devices have been associated with a significantly higher incidence of bleeding complications during surgical procedures \[[18](/articles/10.1186/s40463-018-0295-6#ref-CR18 "Topkara VK, Kondareddy S, Malik F, Wang IW, Mann DL, Ewald GA, Moazami N. Infectious complications in patients with left ventricular assist device: etiology and outcomes in the continuous-flow era. Ann Thorac Surg. 2010;90:1270–7.")\]. In addition, the risk of postoperative infection is substantial in the LVAD population, as infection can seed the hardware \[[19](/articles/10.1186/s40463-018-0295-6#ref-CR19 "Kaplan JA. Ventricular Assist Devices, Cardiac Transplants, and Implanted Electrical Devices in Noncardiac Surgery. Chapter 45. Section 7. Kaplan’s Cardiac Anesthesia: For Cardiac and Noncardiac Surgery. Seventh Edition. 2017.")\]. Patients with LVAD who develop an infection have cumulative survival rates of 66.9% at 2 years compared to 81.3% for patients without an infection \[[20](/articles/10.1186/s40463-018-0295-6#ref-CR20 "Uriel N, et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol. 2010 Oct 5;56(15):1207–13.
https://doi.org/10.1016/j.jacc.2010.05.016
.")\]. Although recent reviews suggest that patients with LVAD can safely undergo non-cardiac surgery \[[21](/articles/10.1186/s40463-018-0295-6#ref-CR21 "Nelson EW, et al. Management of LVAD patients for noncardiac surgery: a single-institution study. J Cardiothorac Vasc Anesth. 2015 Aug;29(4):898–900.
https://doi.org/10.1053/j/jvca.2015.01.017
.")\], other studies showed that perioperative death occurred in a range of 6.4–16.7% \[[22](/articles/10.1186/s40463-018-0295-6#ref-CR22 "Davis J, Sanford D, Schilling J, Hardi A, Colditz G. Systematic review of outcomes after noncardiac surgery in patients with implanted left ventricular assist devices. ASAIO J. 2015 Nov-Dec;61(6):648–51.
https://doi.org/10.1097/MAT.0000000000000278
.")\]. Given these risks, surgery should be considered with caution in this patient population.
Because of the associated co-morbidities and need for anticoagulation with LVADs, a multi-disciplinary approach must be taken in management of epistaxis. In our study, holding anticoagulation was required in some patients, while it was continued in other instances. Interestingly, only 4 (8.2%) patients in this cohort had a supratherapeutic INR, and no association between spontaneous bleeding or multiple interventions with elevated INR was identified. This is consistent with the US-TRACE (STudy of Reduced Anti-Coagulation/Anti-platelEt therapy) study, which found that recurrent bleeding occurred in 52% of cases despite reduced antithrombotic therapy [23], suggesting alternative contributing factors to hemorrhagic complications.
Given the lack of association between INR and recurrent epistaxis, an important contributor may be AvWS, which results from the LVAD itself. LVADs produce continuous blood flow along an axial path using an internal rotor in the blood [[24](/articles/10.1186/s40463-018-0295-6#ref-CR24 "Nascimbene A, Neelamegham S, Frazier OH, Moake JL, Dong JF. Acquired von Willebrand syndrome associated with left ventricular assist device. Blood. 2016 Jun 23;127(25):3133–41. https://doi.org/10.1182/blood-2015-10-636480
.")\]. This results in the loss of large von Willebrand factor (vWF) multimers via a cleavage mechanism. In this situation, AvWS occurs immediately after implantation, and only resolves after device explantation \[[25](/articles/10.1186/s40463-018-0295-6#ref-CR25 "Goda M, et al. Time course of acquire von Willebrand disease associated with two types of continuous-flow left ventricular assist devices: HeartMate II and CicuLite synergy pocket micro-pump. J Heart Lung Transplant. 2013 May;32(5):539–45.
https://doi.org/10.1016/j.healun.2013.02.006
."), [26](/articles/10.1186/s40463-018-0295-6#ref-CR26 "Steinlechner B, et al. Platelet dysfunction in outpatients with left ventricular assist devices. Ann Thorac Surg. 2009 Jan;87(1):131–7.
https://doi.org/10.1016/j.athoracsur.2008.10.027
.")\]. Serious bleeding, defined as episodes that result in death, reoperation, hospitalization, or transfusion, occurs in 19–40% of patients with the HMII, making it the most frequent complication \[[27](/articles/10.1186/s40463-018-0295-6#ref-CR27 "Starling RC, Naka Y, Boyle AJ, et al. Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (interagency registry for mechanically assisted circulatory support). J Am Coll Cardiol. 2011;57(19):1890–8.")\], with the gastrointestinal tract and the nasal cavity being the most common sites \[[28](/articles/10.1186/s40463-018-0295-6#ref-CR28 "Suarez J, Patel CB, Felker GM, Becker R, Hernandez AF, Rogers JG. Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices. Circ Heart Fail. 2011;4(6):779–84.")\]. The proteolytic mechanism that reduces VWF multimers also occurs in those with aortic valve stenosis, pancreatitis, liver cirrhosis, and leukemia \[[29](/articles/10.1186/s40463-018-0295-6#ref-CR29 "Federici AB, Berkowitz SD, Lattuada A, Mannucci PM. Degradation of von Willebrand factor in patients with acquired clinical conditions in which there is heightened proteolysis. Blood. 1993;81(3):720–5.")\]. According to the International Society on Thrombosis and Haemostasis, AvWS is most frequently associated with lymphoproliferative (48%), cardiovascular (21%), myeloproliferative (15%), other neoplastic (5%), and autoimmune disorders (2%) \[[30](/articles/10.1186/s40463-018-0295-6#ref-CR30 "Federici AB, Rand JH, Bucciarelli P, et al. Acquired von Willebrand syndrome: data from an international registry. Thromb Haemost. 2000;84(2):345–9.")\]. Importantly, AvWS must be distinguished from von Willebrand disease (VWD), an inherited disorder, due to different treatment approaches \[[31](/articles/10.1186/s40463-018-0295-6#ref-CR31 "Tiede A, Rand JH, Federici AB, et al. How I treat the acquired von Willebrand syndrome. Blood 2011 117:6777–6785; doi:
https://doi.org/10.1182/blood-2010-11-297580
.")\]. Diagnosis favors AvWS when patients have late onset of bleeding, typically after an uneventful surgery, along with an associated condition and a negative family history of bleeding. Desmopressin and VWF-containing concentrates are treatment options in VWD, but are ineffective in LVAD patients, with removal of the device being the only definitive treatment. Overall, AvWS is a condition that has implications beyond the LVAD population and should be recognized by otolaryngologists.
One limitation of this study is its retrospective nature. Another limitation is that we included only inpatient and emergency room consultations, which were mainly seen by residents of various training levels. Additionally, return visits to the emergency department that did not involve a consultation to otolaryngology were not included. However, we believe that our findings can be applied to care in the outpatient setting.
Conclusion
Patients with LVAD present a unique challenge in the management of their epistaxis. Based on our findings, this difficulty stems from a variety of factors, including the need for anticoagulant or antiplatelet medication, development of irreversible AvWS, and high anesthetic risk. From the otolaryngologic perspective, use of hemostatic packing should be considered as a first-line intervention. Overall, a non-surgical multidisciplinary approach was successful in managing this complex patient population.
Abbreviations
AvWS:
Acquired von Willebrand syndrome
ESPAL:
Endoscopic sphenopalatine artery ligation
HMII:
HeartMate II
INR:
International normalized ratio
PTT:
Partial thromboplastin time
VAD:
Ventricular assist device
VWD:
Von Willebrand disease
VWF:
Von Willebrand factor
References
- Anghel AG, Soreanu CC, Dumitru M, Anghel I. Treatment options for severe epistaxis, the experience of the Coltea ENT clinic. Maedica (Buchar). 2014 Jun;9(2):179–82.
Google Scholar - Shrestha I, Pokharel M, Dhakal A, et al. Study of microorganism growth Patten in nasal pack of patients visiting the department of ENT, head and neck surgery. Kathmandu Univ Med J (KUMJ). 2015 Oct-Dec;13(52):303–7.
CAS Google Scholar - Spielmann PM, Barnes ML, White PS. Controversies in the specialist management of adult epistaxis: an evidence-based review. Clin Otolaryngol. 2012 Oct;37(5):382–9. Doi: 10.111/coa.12024.
- Smith J, Kim D, Dyer C, Siddiq S. Epistaxis in patients taking oral anticoagulant and antiplatelet medication: prospective cohort study. J Laryngol Otol. 2011 Jan;125(1):38–42. https://doi.org/10.1017/S0022215110001921.
Article PubMed CAS Google Scholar - Rubboli A, Becattini C, Verheugt FWA. Incidence, clinical impact and risk of bleeding during oral anticoagulation therapy. World J Cardiol. 2011 Nov 26;3(11):351–8. https://doi.org/10.4330/wjc.v3.i11.351.
Article PubMed PubMed Central Google Scholar - Kirley K, Qato DM, Kornfield R, Stafford RS, Alexander GC. National trends in oral anticoagulant use in the United States, 2007 to 2011.
Google Scholar - Barnes GD, Lucas E, Alexander GC, Goldberger ZD. National Trends in Ambulator Oral Anticoagulant Use. Am J Med. 2015 Dec;128(12):1300–5.e2. doi: https://doi.org/10.1016/j.amjmed.2015.05.044.
- Rossi M, Serraina GF, Jiritano F, Renzuli A. What is the optimal anticoagulation in patients with a left ventricular assist device? Interact Cardiovasc Thorac Surg. 2012 Oct;15(4):733–40. https://doi.org/10.1093/icvts/ivs297.
Article PubMed PubMed Central Google Scholar - Van den Bergh WM, Lanskin-Hartgring AO, Van Duijin AL, Engström AE, Lahpor JR, Slooter AJC. Thromboembolic stroke in patients with a HeartMate –II left ventricular assist device – the role of anticoagulation. J Cardiothorac Surg. 2015;10:128. https://doi.org/10.1186/s13019-015-0333-7.
Article PubMed PubMed Central Google Scholar - Parajuli R. Evaluation of etiology and treatment methods for epistaxis: a review at a tertiary Care Hospital in Central Nepal. Int J Otolaryngol. 2015; https://doi.org/10.1155/2015/283854.
- Rudmik L, Smith TL. Management of intractable spontaneous epistaxis. Am J Rhinol Allergy. 2012 Jan-Feb;26(1):55–60. https://doi.org/10.2500/ajra.2012.26.3696.
Article PubMed PubMed Central Google Scholar - Badran K, Malik TH, Belloso A, Timms MS. Randomized controlled trial comparing Merocel and RapidRhino packing in the management of anterior epistaxis. Clin Otolaryngol. 2005 Aug;30(4):333–7.
Article PubMed CAS Google Scholar - Wang J, Cai C, Wang S. Merocel versus Nasopore for nasal packing: a meta-analysis of randomized controlled trials. PLoS One. 2014 Apr 7;9(4):e93959. https://doi.org/10.1371/journal.pone.0093959.
Article PubMed PubMed Central CAS Google Scholar - Moshaver A, Harris JR, Liu R, Diamond C, Seikaly H. Early operative intervention vs. conventional treatment in epistaxis: randomized prospective trial. J Otolaryngol. 2004 Jun;33(3):185–8.
Article PubMed Google Scholar - Zou Y, Deng YQ, Xia CW, Kong YG, Xu Y, Tao ZZ, Chen SM. Comparison of outcomes between endoscopic surgery and conventional nasal packing for epistaxis fornix of the inferior nasal meatus. Pak J Med Sci. 2015 Nov-Dec;31(6):1361–5. Doi: https://doi.org/10.12669/pjms.316.8340.
- Rudmik L, Leung R. Cost-effectiveness analysis of endoscopic sphenopalatine artery ligation vs arterial embolization for intractable epistaxis. JAMA Otolaryngol Head Neck Surg. 2014;140(9):802–8. https://doi.org/10.1001/jamaoto.2014.1450.
Article PubMed Google Scholar - Liu J, Zhong G, Wang Y. A retrospective analysis of 163 cases with intractable epistaxis managed by nasal endoscopic surgery. Lin Chung Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2013 Jun;27(11):590–2. Chinese.
- Topkara VK, Kondareddy S, Malik F, Wang IW, Mann DL, Ewald GA, Moazami N. Infectious complications in patients with left ventricular assist device: etiology and outcomes in the continuous-flow era. Ann Thorac Surg. 2010;90:1270–7.
Article PubMed Google Scholar - Kaplan JA. Ventricular Assist Devices, Cardiac Transplants, and Implanted Electrical Devices in Noncardiac Surgery. Chapter 45. Section 7. Kaplan’s Cardiac Anesthesia: For Cardiac and Noncardiac Surgery. Seventh Edition. 2017.
- Uriel N, et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol. 2010 Oct 5;56(15):1207–13. https://doi.org/10.1016/j.jacc.2010.05.016.
Article PubMed Google Scholar - Nelson EW, et al. Management of LVAD patients for noncardiac surgery: a single-institution study. J Cardiothorac Vasc Anesth. 2015 Aug;29(4):898–900. https://doi.org/10.1053/j/jvca.2015.01.017.
Article PubMed Google Scholar - Davis J, Sanford D, Schilling J, Hardi A, Colditz G. Systematic review of outcomes after noncardiac surgery in patients with implanted left ventricular assist devices. ASAIO J. 2015 Nov-Dec;61(6):648–51. https://doi.org/10.1097/MAT.0000000000000278.
Article PubMed Google Scholar - Katz JN, Adamson RM, John R, et al. TRACE study. Safety of reduced anti-thrombotic strategies in HeartMate II patients: a one-year analysis of the US-TRACE study. J Heart Lung Transplant. 2015;34(12):1542–8.
Article PubMed Google Scholar - Nascimbene A, Neelamegham S, Frazier OH, Moake JL, Dong JF. Acquired von Willebrand syndrome associated with left ventricular assist device. Blood. 2016 Jun 23;127(25):3133–41. https://doi.org/10.1182/blood-2015-10-636480.
Article PubMed PubMed Central CAS Google Scholar - Goda M, et al. Time course of acquire von Willebrand disease associated with two types of continuous-flow left ventricular assist devices: HeartMate II and CicuLite synergy pocket micro-pump. J Heart Lung Transplant. 2013 May;32(5):539–45. https://doi.org/10.1016/j.healun.2013.02.006.
Article PubMed Google Scholar - Steinlechner B, et al. Platelet dysfunction in outpatients with left ventricular assist devices. Ann Thorac Surg. 2009 Jan;87(1):131–7. https://doi.org/10.1016/j.athoracsur.2008.10.027.
Article PubMed Google Scholar - Starling RC, Naka Y, Boyle AJ, et al. Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (interagency registry for mechanically assisted circulatory support). J Am Coll Cardiol. 2011;57(19):1890–8.
Article PubMed Google Scholar - Suarez J, Patel CB, Felker GM, Becker R, Hernandez AF, Rogers JG. Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices. Circ Heart Fail. 2011;4(6):779–84.
Article PubMed Google Scholar - Federici AB, Berkowitz SD, Lattuada A, Mannucci PM. Degradation of von Willebrand factor in patients with acquired clinical conditions in which there is heightened proteolysis. Blood. 1993;81(3):720–5.
PubMed CAS Google Scholar - Federici AB, Rand JH, Bucciarelli P, et al. Acquired von Willebrand syndrome: data from an international registry. Thromb Haemost. 2000;84(2):345–9.
PubMed CAS Google Scholar - Tiede A, Rand JH, Federici AB, et al. How I treat the acquired von Willebrand syndrome. Blood 2011 117:6777–6785; doi: https://doi.org/10.1182/blood-2010-11-297580.
Acknowledgements
not applicable.
Funding
There are no sources of funding for the research conducted in this study.
Availability of data and materials
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Author’s contributions
CSB performed the study design, literature review, manuscript drafting and review, data analysis and interpretation, accountability for all aspects of the work.
RAH performed manuscript review, interpretation of data, accountability for all aspects of work.
DWJ oversaw the research project, was instrumental in study design, manuscript drafting and review, accountability for all aspects of the work. All authors read and approved the final manuscript.
Author information
Authors and Affiliations
- Division of Head and Neck Surgery & Communication Sciences, Department of Surgery, Duke University Medical Center, DUMC 3805, Durham, NC, 27710, USA
Clifford Scott Brown, Ralph Abi-Hachem & David Woojin Jang
Authors
- Clifford Scott Brown
You can also search for this author inPubMed Google Scholar - Ralph Abi-Hachem
You can also search for this author inPubMed Google Scholar - David Woojin Jang
You can also search for this author inPubMed Google Scholar
Corresponding author
Correspondence toClifford Scott Brown.
Ethics declarations
Ethics approval and consent to participate
This study was approved by the Institutional Review Board at Duke University (Pro00071269).
Consent for publication
not applicable.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Brown, C.S., Abi-Hachem, R. & Jang, D.W. Management of epistaxis in patients with ventricular assist device: a retrospective review.J of Otolaryngol - Head & Neck Surg 47, 48 (2018). https://doi.org/10.1186/s40463-018-0295-6
- Received: 10 April 2018
- Accepted: 27 July 2018
- Published: 02 August 2018
- DOI: https://doi.org/10.1186/s40463-018-0295-6