Seth Taylor | University of Otago (original) (raw)
Papers by Seth Taylor
BMJ Military Health, 2020
BackgroundThe prevalence of civilian 0.223 ammunition is widespread. Due to low costs and the sam... more BackgroundThe prevalence of civilian 0.223 ammunition is widespread. Due to low costs and the same dimensions as a 5.56×45 mm North Atlantic Treaty Organization, this round is exceptionally popular. However, recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds compared with military full metal jacket (FMJ) rounds that do not rapidly expand on impact.MethodsThe aim of this given study is to compare FMJ and SP rounds to determine if there are diagnostic differences between the bullet types in the wounds inflicted to flat bones. Bos taurus scapulae were used for 25 m simulated cranial gunshot injuries. Scanning electron microscopy was employed to assess the difference in wound morphology and elemental analysis between SP and FMJ rounds.ResultsEntrance and exit wound morphology change significantly between the two different types of ammunition as seen with circumferential delamination which is indicative of FMJ rounds and is not seen with the...
BMJ Military Health, 2020
BackgroundHandguns and rifles are often involved in violent deaths such as homicide and suicide. ... more BackgroundHandguns and rifles are often involved in violent deaths such as homicide and suicide. Consequently, forensic investigations are important to clarify the nature of ballistic trauma.MethodsThis study investigated the differences in entrance and exit wound morphology with Bos taurus (bovine) scapulae that have two cortical layers surrounding a central cancellous bone section which are comparable with human flat bones, with a series of experiments using six different calibres (0.22 Long Rifle, 9×19 mm North Atlantic Treaty Organization, 0.40 Smith & Wesson, 0.45 Automatic Colt Pistol, 5.56×45 mm and 7.62×51 mm). B. taurus (bovine) scapulae were used for closed range 30 cm simulated executions.ResultsThe ballistic experiments presented similarities in entrance wound morphology and exit wound bevelling with that of recognised forensic cases. As muzzle velocity increased, bevelling increased. Circumferential delamination is clearly visible with full metal jacket rounds, yielding...
Forensic Science, Medicine and Pathology, 2022
Rifles are often involved in violent deaths such as homicide and suicide. Consequently, expert kn... more Rifles are often involved in violent deaths such as homicide and suicide. Consequently, expert knowledge and experimental forensic investigations are important to clarify the nature of ballistic trauma when applied to the human head and neurocranium. This study investigated differences in entrance wound morphology with Synbone® spheres which are described as being comparable to human flat bones. A series of ballistic experiments were conducted using two different rifle calibers (5.56 × 45 mm and 7.62 × 39 mm Full Metal Jacket (FMJ)). Synbone® spheres were used for close-range 0.3 m simulated executions as well as at 25 m and 35 m to simulate urban and military engagements. Results were compared with previously published experimental studies using similar military ammunition. In our study, entry wound morphology closely resembles real forensic cases compared to exit wound and overall shape morphology independently of the distance and the caliber. Circumferential delamination was clea...
Egyptian Journal of Forensic Sciences, 2020
Background In the absence of cadaveric tissues, forensic simulation, trauma modelling, and crania... more Background In the absence of cadaveric tissues, forensic simulation, trauma modelling, and cranial surgical training necessitates a surrogate for the human calvaria. This study investigates the validity of Bos taurus scapulae as a proxy for human frontal bones by comparing the laminar and cancellous bone thickness, as well as the bone mineral density (BMD) of cadaveric frontal bones and adult Bos taurus scapulae. Results This study aimed to validate the bovine scapulae as a valid proxy for forensic experiments, which benefit researchers and investigators who need to recreate forensic scenarios where synthetic proxies are found unsuitable due to their non-viscoelastic nature and cadaveric human models are unavailable due to ethical restrictions. Our results identified different total thicknesses of the relative bones, but non-different cortical measurements between human frontal bone and bovine scapulae. The bone mineral density is similar between both groups. Conclusion This study h...
Forensic science international, 2018
Gun violence is a global phenomenon with regional variation in frequency and severity. Handguns a... more Gun violence is a global phenomenon with regional variation in frequency and severity. Handguns are often used in violent deaths such as suicides and homicides. Hence, ballistic trauma is a critical subject of forensic investigations. Trauma patterns are fundamental evidence for the reconstruction of the incident and for the determination of the manner of death. This study investigated the differences in trauma patterns with a series of experiments using six different calibers (.22 LR, .38 Special, .380 ACP, 9×19mm, .40 S&W, and .45 ACP) and four different bullet types. Synbone® spheres (polyurethane bone proxies) were used for close range 30cm simulated executions. The polyurethane spheres constitute an excellent proxy for human crania at the macroscopic level as suggested by other studies. The results showed that the radius of the entrance wound is positively correlated (Pearson's correlation coefficient R=0.846, p<0.05) with the caliber dimension. As muzzle velocity increa...
Background: In the absence of cadaveric tissues, forensic simulation, trauma modelling, and crani... more Background: In the absence of cadaveric tissues, forensic simulation, trauma modelling, and cranial surgical training necessitates a surrogate for the human calvaria. This study investigates the validity of Bos taurus scapulae as a proxy for human frontal bones by comparing the laminar and cancellous bone thickness, as well as the bone mineral density (BMD) of cadaveric frontal bones and adult Bos taurus scapulae. Results: This study aimed to validate the bovine scapulae as a valid proxy for forensic experiments, which benefit researchers and investigators who need to recreate forensic scenarios where synthetic proxies are found unsuitable due to their non-viscoelastic nature and cadaveric human models are unavailable due to ethical restrictions. Our results identified different total thicknesses of the relative bones, but non-different cortical measurements between human frontal bone and bovine scapulae. The bone mineral density is similar between both groups. Conclusion: This study has found Bos taurus scapulae to be a suitable proxy for human frontal bones as it has a similar morphology with regard to thickness and structure as well as a comparable density. However, there is a significant difference between the cancellous bone, and therefore, the overall thickness.
Bos taurus used in ballistic experiments presented similarities in entrance wound morphology and ... more Bos taurus used in ballistic experiments presented similarities in entrance wound morphology and exit wound bevelling with that of recognised forensic cases. ► As muzzle velocity increased, bevelling increased. ► Circumferential delamination is clearly visible with full metal jacket rounds, yielding similar bone damage morphology as human crania. ► B. taurus scapulae seem appropriate for ballistic simulations of cranial injuries on the macroscopic level, if the correct portion of the scapulae is deployed. AbsTrACT background Handguns and rifles are often involved in violent deaths such as homicide and suicide. Consequently, forensic investigations are important to clarify the nature of ballistic trauma. Methods This study investigated the differences in entrance and exit wound morphology with Bos taurus (bovine) scapulae that have two cortical layers surrounding a central cancellous bone section which are comparable with human flat bones, with a series of experiments using six different calibres (0.22 Long Rifle, 9×19 mm North Atlantic Treaty Organization, 0.40 Smith & Wesson, 0.45 Automatic Colt Pistol, 5.56×45 mm and 7.62×51 mm). B. taurus (bovine) scapulae were used for closed range 30 cm simulated executions. results The ballistic experiments presented similarities in entrance wound morphology and exit wound bevelling with that of recognised forensic cases. As muzzle velocity increased, bevelling increased. Circumferential delamination is clearly visible with full metal jacket rounds, yielding similar bone damage morphology as human crania. Conclusion Bovine scapulae seem appropriate for ballistic simulations of flat bone injuries on the macroscopic level, if the correct portion of the scapulae is deployed. More research is needed to further substantiate these interpretations.
Recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds... more Recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds. ► Scanning electron microscopy was employed to assess the difference in wound morphology and elemental analysis between SP and full metal jacket (FMJ) rounds. ► Gunshot flat bone wound morphology is distinctively different between SP and FMJ rounds. ► Lead staining of the entrance wound is visible on only the SP rounds. ► Entrance and exit wound morphology change significantly between the two different types of ammunition. AbsTrACT background The prevalence of civilian 0.223 ammunition is widespread. Due to low costs and the same dimensions as a 5.56×45 mm North Atlantic Treaty Organization, this round is exceptionally popular. However, recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds compared with military full metal jacket (FMJ) rounds that do not rapidly expand on impact. Methods The aim of this given study is to compare FMJ and SP rounds to determine if there are diagnostic differences between the bullet types in the wounds inflicted to flat bones. Bos taurus scapulae were used for 25 m simulated cranial gunshot injuries. Scanning electron microscopy was employed to assess the difference in wound morphology and elemental analysis between SP and FMJ rounds. results Entrance and exit wound morphology change significantly between the two different types of ammunition as seen with circumferential delamination which is indicative of FMJ rounds and is not seen with the softer SP hunting rounds. Lead staining of the entrance wound is visible on only the SP rounds. Conclusion Gunshot flat bone wound morphology is distinctively different between SP and FMJ rounds. Circumferential delamination is only seen with FMJ due to the hardness of the round. Lead staining is only seen with SP rounds due to bullet composition.
A B S T R A C T Gun violence is a global phenomenon with regional variation in frequency and seve... more A B S T R A C T Gun violence is a global phenomenon with regional variation in frequency and severity. Handguns are often used in violent deaths such as suicides and homicides. Hence, ballistic trauma is a critical subject of forensic investigations. Trauma patterns are fundamental evidence for the reconstruction of the incident and for the determination of the manner of death. This study investigated the differences in trauma patterns with a series of experiments using six different calibers (.22 LR, .38 Special, .380 ACP, 9 Â 19 mm, .40 S&W, and .45 ACP) and four different bullet types. Synbone 1 spheres (polyurethane bone proxies) were used for close range 30 cm simulated executions. The polyurethane spheres constitute an excellent proxy for human crania at the macroscopic level as suggested by other studies. The results showed that the radius of the entrance wound is positively correlated (Pearson's correlation coefficient R = 0.846, p < 0.05) with the caliber dimension. As muzzle velocity increased, endocranial beveling increased. Bullet weight, conversely, does not seem to have an effect on the size of the endocranial beveling present in Synbone 1 spheres. The ballistic experiments exhibited similarities in entrance wound morphology; radial and concentric fracture patterns, hydraulic burst effect, circumferential delamination, and endocranial beveling with that of documented forensic cases with corresponding caliber shot. Synbone spheres seem appropriate for ballistic simulations of cranial injuries; yet, more research is needed to verify these observations.
BMJ Military Health, 2020
BackgroundThe prevalence of civilian 0.223 ammunition is widespread. Due to low costs and the sam... more BackgroundThe prevalence of civilian 0.223 ammunition is widespread. Due to low costs and the same dimensions as a 5.56×45 mm North Atlantic Treaty Organization, this round is exceptionally popular. However, recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds compared with military full metal jacket (FMJ) rounds that do not rapidly expand on impact.MethodsThe aim of this given study is to compare FMJ and SP rounds to determine if there are diagnostic differences between the bullet types in the wounds inflicted to flat bones. Bos taurus scapulae were used for 25 m simulated cranial gunshot injuries. Scanning electron microscopy was employed to assess the difference in wound morphology and elemental analysis between SP and FMJ rounds.ResultsEntrance and exit wound morphology change significantly between the two different types of ammunition as seen with circumferential delamination which is indicative of FMJ rounds and is not seen with the...
BMJ Military Health, 2020
BackgroundHandguns and rifles are often involved in violent deaths such as homicide and suicide. ... more BackgroundHandguns and rifles are often involved in violent deaths such as homicide and suicide. Consequently, forensic investigations are important to clarify the nature of ballistic trauma.MethodsThis study investigated the differences in entrance and exit wound morphology with Bos taurus (bovine) scapulae that have two cortical layers surrounding a central cancellous bone section which are comparable with human flat bones, with a series of experiments using six different calibres (0.22 Long Rifle, 9×19 mm North Atlantic Treaty Organization, 0.40 Smith & Wesson, 0.45 Automatic Colt Pistol, 5.56×45 mm and 7.62×51 mm). B. taurus (bovine) scapulae were used for closed range 30 cm simulated executions.ResultsThe ballistic experiments presented similarities in entrance wound morphology and exit wound bevelling with that of recognised forensic cases. As muzzle velocity increased, bevelling increased. Circumferential delamination is clearly visible with full metal jacket rounds, yielding...
Forensic Science, Medicine and Pathology, 2022
Rifles are often involved in violent deaths such as homicide and suicide. Consequently, expert kn... more Rifles are often involved in violent deaths such as homicide and suicide. Consequently, expert knowledge and experimental forensic investigations are important to clarify the nature of ballistic trauma when applied to the human head and neurocranium. This study investigated differences in entrance wound morphology with Synbone® spheres which are described as being comparable to human flat bones. A series of ballistic experiments were conducted using two different rifle calibers (5.56 × 45 mm and 7.62 × 39 mm Full Metal Jacket (FMJ)). Synbone® spheres were used for close-range 0.3 m simulated executions as well as at 25 m and 35 m to simulate urban and military engagements. Results were compared with previously published experimental studies using similar military ammunition. In our study, entry wound morphology closely resembles real forensic cases compared to exit wound and overall shape morphology independently of the distance and the caliber. Circumferential delamination was clea...
Egyptian Journal of Forensic Sciences, 2020
Background In the absence of cadaveric tissues, forensic simulation, trauma modelling, and crania... more Background In the absence of cadaveric tissues, forensic simulation, trauma modelling, and cranial surgical training necessitates a surrogate for the human calvaria. This study investigates the validity of Bos taurus scapulae as a proxy for human frontal bones by comparing the laminar and cancellous bone thickness, as well as the bone mineral density (BMD) of cadaveric frontal bones and adult Bos taurus scapulae. Results This study aimed to validate the bovine scapulae as a valid proxy for forensic experiments, which benefit researchers and investigators who need to recreate forensic scenarios where synthetic proxies are found unsuitable due to their non-viscoelastic nature and cadaveric human models are unavailable due to ethical restrictions. Our results identified different total thicknesses of the relative bones, but non-different cortical measurements between human frontal bone and bovine scapulae. The bone mineral density is similar between both groups. Conclusion This study h...
Forensic science international, 2018
Gun violence is a global phenomenon with regional variation in frequency and severity. Handguns a... more Gun violence is a global phenomenon with regional variation in frequency and severity. Handguns are often used in violent deaths such as suicides and homicides. Hence, ballistic trauma is a critical subject of forensic investigations. Trauma patterns are fundamental evidence for the reconstruction of the incident and for the determination of the manner of death. This study investigated the differences in trauma patterns with a series of experiments using six different calibers (.22 LR, .38 Special, .380 ACP, 9×19mm, .40 S&W, and .45 ACP) and four different bullet types. Synbone® spheres (polyurethane bone proxies) were used for close range 30cm simulated executions. The polyurethane spheres constitute an excellent proxy for human crania at the macroscopic level as suggested by other studies. The results showed that the radius of the entrance wound is positively correlated (Pearson's correlation coefficient R=0.846, p<0.05) with the caliber dimension. As muzzle velocity increa...
Background: In the absence of cadaveric tissues, forensic simulation, trauma modelling, and crani... more Background: In the absence of cadaveric tissues, forensic simulation, trauma modelling, and cranial surgical training necessitates a surrogate for the human calvaria. This study investigates the validity of Bos taurus scapulae as a proxy for human frontal bones by comparing the laminar and cancellous bone thickness, as well as the bone mineral density (BMD) of cadaveric frontal bones and adult Bos taurus scapulae. Results: This study aimed to validate the bovine scapulae as a valid proxy for forensic experiments, which benefit researchers and investigators who need to recreate forensic scenarios where synthetic proxies are found unsuitable due to their non-viscoelastic nature and cadaveric human models are unavailable due to ethical restrictions. Our results identified different total thicknesses of the relative bones, but non-different cortical measurements between human frontal bone and bovine scapulae. The bone mineral density is similar between both groups. Conclusion: This study has found Bos taurus scapulae to be a suitable proxy for human frontal bones as it has a similar morphology with regard to thickness and structure as well as a comparable density. However, there is a significant difference between the cancellous bone, and therefore, the overall thickness.
Bos taurus used in ballistic experiments presented similarities in entrance wound morphology and ... more Bos taurus used in ballistic experiments presented similarities in entrance wound morphology and exit wound bevelling with that of recognised forensic cases. ► As muzzle velocity increased, bevelling increased. ► Circumferential delamination is clearly visible with full metal jacket rounds, yielding similar bone damage morphology as human crania. ► B. taurus scapulae seem appropriate for ballistic simulations of cranial injuries on the macroscopic level, if the correct portion of the scapulae is deployed. AbsTrACT background Handguns and rifles are often involved in violent deaths such as homicide and suicide. Consequently, forensic investigations are important to clarify the nature of ballistic trauma. Methods This study investigated the differences in entrance and exit wound morphology with Bos taurus (bovine) scapulae that have two cortical layers surrounding a central cancellous bone section which are comparable with human flat bones, with a series of experiments using six different calibres (0.22 Long Rifle, 9×19 mm North Atlantic Treaty Organization, 0.40 Smith & Wesson, 0.45 Automatic Colt Pistol, 5.56×45 mm and 7.62×51 mm). B. taurus (bovine) scapulae were used for closed range 30 cm simulated executions. results The ballistic experiments presented similarities in entrance wound morphology and exit wound bevelling with that of recognised forensic cases. As muzzle velocity increased, bevelling increased. Circumferential delamination is clearly visible with full metal jacket rounds, yielding similar bone damage morphology as human crania. Conclusion Bovine scapulae seem appropriate for ballistic simulations of flat bone injuries on the macroscopic level, if the correct portion of the scapulae is deployed. More research is needed to further substantiate these interpretations.
Recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds... more Recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds. ► Scanning electron microscopy was employed to assess the difference in wound morphology and elemental analysis between SP and full metal jacket (FMJ) rounds. ► Gunshot flat bone wound morphology is distinctively different between SP and FMJ rounds. ► Lead staining of the entrance wound is visible on only the SP rounds. ► Entrance and exit wound morphology change significantly between the two different types of ammunition. AbsTrACT background The prevalence of civilian 0.223 ammunition is widespread. Due to low costs and the same dimensions as a 5.56×45 mm North Atlantic Treaty Organization, this round is exceptionally popular. However, recent mass shootings have employed soft point (SP) expanding ammunition to cause grievous wounds compared with military full metal jacket (FMJ) rounds that do not rapidly expand on impact. Methods The aim of this given study is to compare FMJ and SP rounds to determine if there are diagnostic differences between the bullet types in the wounds inflicted to flat bones. Bos taurus scapulae were used for 25 m simulated cranial gunshot injuries. Scanning electron microscopy was employed to assess the difference in wound morphology and elemental analysis between SP and FMJ rounds. results Entrance and exit wound morphology change significantly between the two different types of ammunition as seen with circumferential delamination which is indicative of FMJ rounds and is not seen with the softer SP hunting rounds. Lead staining of the entrance wound is visible on only the SP rounds. Conclusion Gunshot flat bone wound morphology is distinctively different between SP and FMJ rounds. Circumferential delamination is only seen with FMJ due to the hardness of the round. Lead staining is only seen with SP rounds due to bullet composition.
A B S T R A C T Gun violence is a global phenomenon with regional variation in frequency and seve... more A B S T R A C T Gun violence is a global phenomenon with regional variation in frequency and severity. Handguns are often used in violent deaths such as suicides and homicides. Hence, ballistic trauma is a critical subject of forensic investigations. Trauma patterns are fundamental evidence for the reconstruction of the incident and for the determination of the manner of death. This study investigated the differences in trauma patterns with a series of experiments using six different calibers (.22 LR, .38 Special, .380 ACP, 9 Â 19 mm, .40 S&W, and .45 ACP) and four different bullet types. Synbone 1 spheres (polyurethane bone proxies) were used for close range 30 cm simulated executions. The polyurethane spheres constitute an excellent proxy for human crania at the macroscopic level as suggested by other studies. The results showed that the radius of the entrance wound is positively correlated (Pearson's correlation coefficient R = 0.846, p < 0.05) with the caliber dimension. As muzzle velocity increased, endocranial beveling increased. Bullet weight, conversely, does not seem to have an effect on the size of the endocranial beveling present in Synbone 1 spheres. The ballistic experiments exhibited similarities in entrance wound morphology; radial and concentric fracture patterns, hydraulic burst effect, circumferential delamination, and endocranial beveling with that of documented forensic cases with corresponding caliber shot. Synbone spheres seem appropriate for ballistic simulations of cranial injuries; yet, more research is needed to verify these observations.