Regeneration of segmental diaphyseal defects in sheep tibiae using resorbable polymeric membranes: a preliminary study - PubMed (original) (raw)
Comparative Study
Regeneration of segmental diaphyseal defects in sheep tibiae using resorbable polymeric membranes: a preliminary study
Z Gugala et al. J Orthop Trauma. 1999 Mar-Apr.
Abstract
Objective: To investigate whether a long bone cortex of well-defined thickness can be regenerated by using an anatomically designed membranous resorbable "tube-in-tube" implant and to establish the functions of membranes in the healing of segmental diaphyseal bone defects larger than the "critical size."
Design: Bone healing in segmental diaphyseal defects larger than the critical size in the sheep tibiae covered with a single porous tubular membrane or implanted with anatomically shaped porous double tube-in-tube membranes was evaluated. Membranes with different pore structures were applied alone and/or in combination with autogenous bone graft.
Background: Healing of segmental diaphyseal bone defects in animals can be enhanced by covering the defects with resorbable polylactide membranes. Based on the results of bone healing in defects ten millimeters long in the rabbit radii, it was suggested that the membrane prevents muscle and soft tissue from invading the defect and maintains osteogenic cells and osteogenic substances within the space covered with membrane, thus promoting new bone formation. The functions of membranes may differ, however, depending on the size and the location of the defect and on the experimental species used. Bone defects larger than the critical size may not heal at all, even if membranes are used. The critical-size defect is defined as the smallest bone defect that does not heal spontaneously when covered with polymeric membranes. To heal such defects, it is mandatory that membranes are used in combination with autogenic bone graft and/or a suitable bone substitute. If bone graft is used to fill the defect, the structure and geometry of the covering membrane will determine whether the graft will be vascularized and/or nourished from the surrounding soft tissue and, in consequence, survive. It can be appreciated that bone healing in areas of good vascularity should be more efficient than bone healing in poorly vascularized areas. The influence of all these factors on healing of bone in segmental diaphyseal defects covered with membranes is not known.
Methods: Four-centimeter-long diaphyseal segmental defects in the tibiae of six- to seven-year-old Swiss mountain sheep were covered with resorbable membranes from poly(LDL-lactide). In Group 1, a single microporous external membrane was used. In Group 2, one microporous membrane was inserted into the medullary cavity at the cut ends of the tibiae (internal membrane), and the other microporous membrane was placed on the outer surface of the cortex (external membrane). In Group 3, a single microporous external membrane was also laser-perforated to produce openings with a diameter in the range of 800 to 900 micrometers. In Group 4, the defect was filled with autogenous cancellous bone graft and covered with a single perforated membrane. In Group 5, one perforated internal membrane was inserted into the medullary cavity at the cut ends of the tibiae, and the other perforated membrane was placed on the outer surface of the cortex. Group 6 was identical to Group 5, except that cancellous bone graft was placed in the space between these two membranes.
Results: There was no bone healing in Groups 1, 2, 3, and 5. Only in Groups 4 and 6 did the defects heal. In Group 4, new bone was dispersed across the "medullary canal" formed by the membrane. In Group 6, the new bone had grown into the space between the outer and inner membranes, forming the "neocortex."
Conclusions: The resorbable polymeric implant consisting of two concentric perforated membranes (the tube-in-tube implant) used in combination with cancellous bone graft to treat segmental diaphyseal defects in sheep tibiae allows for the reconstitution of the "neocortex" with well-defined thickness. (ABSTRACT TRUNCATED)
Comment in
- Regeneration of bone in critical defects.
Cornell CN. Cornell CN. J Orthop Trauma. 1999 Sep-Oct;13(7):523-4. doi: 10.1097/00005131-199909000-00023. J Orthop Trauma. 1999. PMID: 10513979 No abstract available.
Similar articles
- Bone regeneration in segmental defects with resorbable polymeric membranes: IV. Does the polymer chemical composition affect the healing process?
Gogolewski S, Pineda L, Büsing CM. Gogolewski S, et al. Biomaterials. 2000 Dec;21(24):2513-20. doi: 10.1016/s0142-9612(00)00119-8. Biomaterials. 2000. PMID: 11071601 - Regeneration of diaphyseal bone defects using resorbable poly(L/DL-lactide) and poly(D-lactide) membranes in the Yucatan pig model.
Meinig RP, Buesing CM, Helm J, Gogolewski S. Meinig RP, et al. J Orthop Trauma. 1997 Nov;11(8):551-8. doi: 10.1097/00005131-199711000-00002. J Orthop Trauma. 1997. PMID: 9415860 - [Defect fractures of the tibia--various forms of bone replacement].
Mittelmeier W, Braun C, Gradinger R. Mittelmeier W, et al. Chirurg. 1996 Nov;67(11):1087-92. doi: 10.1007/s001040050108. Chirurg. 1996. PMID: 9035942 Review. German. - Prosthetic devices shaped as tubular chambers for the treatment of large diaphyseal defects by guided bone regeneration.
Nicoli Aldini N, Fini M, Giavaresi G, Guzzardella GA, Giardino R. Nicoli Aldini N, et al. Int J Artif Organs. 2005 Jan;28(1):51-7. doi: 10.1177/039139880502800109. Int J Artif Organs. 2005. PMID: 15742310 Review.
Cited by
- Elastomeric enriched biodegradable polyurethane sponges for critical bone defects: a successful case study reducing donor site morbidity.
Lavrador C, Mascarenhas R, Coelho P, Brites C, Pereira A, Gogolewski S. Lavrador C, et al. J Mater Sci Mater Med. 2016 Mar;27(3):61. doi: 10.1007/s10856-016-5667-8. Epub 2016 Jan 22. J Mater Sci Mater Med. 2016. PMID: 26800692 - The 'Ziran' wrap: reconstruction of critical-sized long bone defects using a fascial autograft and reamer-irrigator-aspirator autograft.
Ziran NM, Smith WR. Ziran NM, et al. Patient Saf Surg. 2014 Oct 4;8(1):40. doi: 10.1186/s13037-014-0040-7. eCollection 2014. Patient Saf Surg. 2014. PMID: 25298784 Free PMC article. - Micropore-induced capillarity enhances bone distribution in vivo in biphasic calcium phosphate scaffolds.
Rustom LE, Boudou T, Lou S, Pignot-Paintrand I, Nemke BW, Lu Y, Markel MD, Picart C, Wagoner Johnson AJ. Rustom LE, et al. Acta Biomater. 2016 Oct 15;44:144-54. doi: 10.1016/j.actbio.2016.08.025. Epub 2016 Aug 17. Acta Biomater. 2016. PMID: 27544807 Free PMC article. - In vivo bone regeneration assessment of offset and gradient melt electrowritten (MEW) PCL scaffolds.
Abbasi N, Lee RSB, Ivanovski S, Love RM, Hamlet S. Abbasi N, et al. Biomater Res. 2020 Oct 1;24:17. doi: 10.1186/s40824-020-00196-1. eCollection 2020. Biomater Res. 2020. PMID: 33014414 Free PMC article. - The role of barrier membranes for guided bone regeneration and restoration of large bone defects: current experimental and clinical evidence.
Dimitriou R, Mataliotakis GI, Calori GM, Giannoudis PV. Dimitriou R, et al. BMC Med. 2012 Jul 26;10:81. doi: 10.1186/1741-7015-10-81. BMC Med. 2012. PMID: 22834465 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical