3D z-shim method for reduction of susceptibility effects in BOLD fMRI
G H Glover. Magn Reson Med. 1999 Aug.
Free article
Abstract
Susceptibility-induced magnetic field gradients (SFGs) perpendicular to the slice plane often result in signal dropout in blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) experiments. Two-dimensional (2D) z-shim methods reduce these effects by acquiring multiple images with different slice refocusing gradient areas. In this work a 3D z-shim method is introduced as a more efficient alternative. The technique augments the k-space data for a conventional 3D phase encoding acquisition with N additional lines that extend the k(z) coverage sufficiently to sample k-space fully in regions with SFGs. Multiple subsets of these data are reconstructed using a sliding window that provides N +1 z-shim images. Fewer total acquisitions are required than with the 2D method for the same coverage, and finer z-shim steps are obtained. The technique is demonstrated with a motor task using intentionally introduced SFGs and compared with the 2D method. The results confirm increased BOLD SNR and activation with the new method in good agreement with theory. Magn Reson Med 42:290-299, 1999.
Copyright 1999 Wiley-Liss, Inc.
Similar articles
- Single-shot dual-z-shimmed sensitivity-encoded spiral-in/out imaging for functional MRI with reduced susceptibility artifacts.
Truong TK, Song AW. Truong TK, et al. Magn Reson Med. 2008 Jan;59(1):221-7. doi: 10.1002/mrm.21473. Magn Reson Med. 2008. PMID: 18050341 - Real-time feedback optimization of z-shim gradient for automatic compensation of susceptibility-induced signal loss in EPI.
Tang YW, Huang TY. Tang YW, et al. Neuroimage. 2011 Apr 15;55(4):1587-92. doi: 10.1016/j.neuroimage.2011.01.045. Epub 2011 Jan 20. Neuroimage. 2011. PMID: 21256230 - Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation.
Du YP, Dalwani M, Wylie K, Claus E, Tregellas JR. Du YP, et al. Magn Reson Med. 2007 Feb;57(2):396-404. doi: 10.1002/mrm.21150. Magn Reson Med. 2007. PMID: 17260355 - Three-dimensional spiral fMRI technique: a comparison with 2D spiral acquisition.
Lai S, Glover GH. Lai S, et al. Magn Reson Med. 1998 Jan;39(1):68-78. doi: 10.1002/mrm.1910390112. Magn Reson Med. 1998. PMID: 9438439 - Automated slice-specific simultaneous z-shim method for reducing B1 inhomogeneity and susceptibility-induced signal loss with parallel transmission at 3T.
Schneider R, Boada F, Haueisen J, Pfeuffer J. Schneider R, et al. Magn Reson Med. 2015 Oct;74(4):934-44. doi: 10.1002/mrm.25461. Epub 2014 Oct 7. Magn Reson Med. 2015. PMID: 25291423 Free PMC article.
Cited by
- Prediction of motion induced magnetic fields for human brain MRI at 3 T.
Zhou J, Hagberg GE, Aghaeifar A, Bause J, Zaitsev M, Scheffler K. Zhou J, et al. MAGMA. 2023 Oct;36(5):797-813. doi: 10.1007/s10334-023-01076-0. Epub 2023 Mar 25. MAGMA. 2023. PMID: 36964797 Free PMC article. - Automated slice-specific z-shimming for functional magnetic resonance imaging of the human spinal cord.
Kaptan M, Vannesjo SJ, Mildner T, Horn U, Hartley-Davies R, Oliva V, Brooks JCW, Weiskopf N, Finsterbusch J, Eippert F. Kaptan M, et al. Hum Brain Mapp. 2022 Dec 15;43(18):5389-5407. doi: 10.1002/hbm.26018. Epub 2022 Aug 8. Hum Brain Mapp. 2022. PMID: 35938527 Free PMC article. - Functional Activities Detected in the Olfactory Bulb and Associated Olfactory Regions in the Human Brain Using T2-Prepared BOLD Functional MRI at 7T.
Miao X, Paez AG, Rajan S, Cao D, Liu D, Pantelyat AY, Rosenthal LI, van Zijl PCM, Bassett SS, Yousem DM, Kamath V, Hua J. Miao X, et al. Front Neurosci. 2021 Sep 13;15:723441. doi: 10.3389/fnins.2021.723441. eCollection 2021. Front Neurosci. 2021. PMID: 34588949 Free PMC article. - Application of an integrated radio-frequency/shim coil technology for signal recovery in fMRI.
Willey D, Darnell D, Song AW, Truong TK. Willey D, et al. Magn Reson Med. 2021 Dec;86(6):3067-3081. doi: 10.1002/mrm.28925. Epub 2021 Jul 20. Magn Reson Med. 2021. PMID: 34288086 Free PMC article. - Slice encoding for the reduction of outflow signal artifacts in cine balanced SSFP imaging.
Ali F, Bydder M, Han H, Wang D, Ghodrati V, Gao C, Prosper A, Nguyen KL, Finn JP, Hu P. Ali F, et al. Magn Reson Med. 2021 Oct;86(4):2034-2048. doi: 10.1002/mrm.28858. Epub 2021 May 31. Magn Reson Med. 2021. PMID: 34056755 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical