Cellular proliferation and macrophage populations associated with implanted expanded polytetrafluoroethylene and polyethyleneterephthalate
R D Hagerty et al. J Biomed Mater Res. 2000.
Abstract
The chronic inflammatory response associated with the abluminal surface of polymeric vascular grafts has been suggested to affect adversely graft neovascularization, the cellular response at the luminal surface of vascular grafts, and overall graft patency. To better understand the source for this chronic inflammation, this study examined two types of macrophages and the amount of cellular proliferation around two widely used graft materials, expanded polytetrafluoroethylene (ePTFE) and polyethyleneterephthalate (PET or Dacron) implanted in the rat for 3 and 5 weeks. Serial sections of explants were analyzed for recruited macrophages (ED1), resident macrophages (ED2), and proliferating cells (PCNA). Results show that Dacron is more inflammatory than ePTFE and that there is a segregated macrophage response; the first 54 micrometer of perigraft tissue were composed predominantly of recruited macrophages (ED1+) while the more distal tissue consisted of resident macrophages (ED2+). Proliferating cells were located predominantly in this same 54 micrometer perigraft region. In subcutaneous tissue they accounted for 23% of all cells present around Dacron after 3 weeks of implantation and 8% after 5 weeks. Conversely, cellular proliferation around ePTFE increased from 4% at 3 weeks to 21% at 5 weeks. In adipose tissue, proliferation levels around the implanted polymers were lower and more similar after 3 and 5 weeks. Serial sections revealed the coordinate expression of PCNA and ED1 antigens by the same individual cells, suggesting that proliferation is a mechanism used to perpetuate the chronic inflammatory response. These results suggest a new target for designing treatments to alter inflammation and improve the healing associated with these biomaterials.
Copyright 2000 John Wiley & Sons, Inc.
Similar articles
- Inflammation and neovascularization associated with clinically used vascular prosthetic materials.
Salzmann DL, Kleinert LB, Berman SS, Williams SK. Salzmann DL, et al. Cardiovasc Pathol. 1999 Mar-Apr;8(2):63-71. doi: 10.1016/s1054-8807(98)00003-9. Cardiovasc Pathol. 1999. PMID: 10724503 - Polyurethane vascular prostheses decreases neointimal formation compared with expanded polytetrafluoroethylene.
Jeschke MG, Hermanutz V, Wolf SE, Köveker GB. Jeschke MG, et al. J Vasc Surg. 1999 Jan;29(1):168-76. doi: 10.1016/s0741-5214(99)70358-7. J Vasc Surg. 1999. PMID: 9882801 - Healing response associated with balloon-dilated ePTFE.
Salzmann DL, Yee DC, Roach DJ, Berman SS, Williams SK. Salzmann DL, et al. J Biomed Mater Res. 1998 Sep 5;41(3):364-70. doi: 10.1002/(sici)1097-4636(19980905)41:3<364::aid-jbm4>3.0.co;2-a. J Biomed Mater Res. 1998. PMID: 9659604 - [Biomaterials and technologies for vascular grafts: from bench to bedside].
Losi P, Briganti E, Vaghetti M, Soldani G. Losi P, et al. Recenti Prog Med. 2013 Jan;104(1):1-9. doi: 10.1701/1226.13588. Recenti Prog Med. 2013. PMID: 23439534 Review. Italian. - A meta-analysis to compare Dacron versus polytetrafluroethylene grafts for above-knee femoropopliteal artery bypass.
Rychlik IJ, Davey P, Murphy J, O'Donnell ME. Rychlik IJ, et al. J Vasc Surg. 2014 Aug;60(2):506-15. doi: 10.1016/j.jvs.2014.05.049. Epub 2014 Jun 25. J Vasc Surg. 2014. PMID: 24973288 Review.
Cited by
- Physiological Appearance of Hybrid FDG-Positron Emission Tomography/Computed Tomography Imaging Following Uncomplicated Endovascular Aneurysm Sealing Using the Nellix Endoprosthesis.
Groot Jebbink E, van Den Ham LH, van Woudenberg BBJ, Slart RHJA, Zeebregts CJ, Rijnders TJM, Lardenoije JHP, Reijnen MMPJ. Groot Jebbink E, et al. J Endovasc Ther. 2020 Jun;27(3):509-515. doi: 10.1177/1526602820913888. Epub 2020 Apr 15. J Endovasc Ther. 2020. PMID: 32295455 Free PMC article. - Usefulness of increased 18F-FDG uptake for detecting local recurrence in patients with extremity osteosarcoma treated with surgical resection and endoprosthetic replacement.
Chang KJ, Kong CB, Cho WH, Jeon DG, Lee SY, Lim I, Lim SM. Chang KJ, et al. Skeletal Radiol. 2015 Apr;44(4):529-37. doi: 10.1007/s00256-014-2063-7. Epub 2014 Nov 29. Skeletal Radiol. 2015. PMID: 25431093 - 18F-Fluorodeoxyglucose positron emission tomography/CT scanning in diagnosing vascular prosthetic graft infection.
Saleem BR, Pol RA, Slart RH, Reijnen MM, Zeebregts CJ. Saleem BR, et al. Biomed Res Int. 2014;2014:471971. doi: 10.1155/2014/471971. Epub 2014 Aug 19. Biomed Res Int. 2014. PMID: 25210712 Free PMC article. Review. - Influence of a new self-gripping hernia mesh on male fertility in a rat model.
Kolbe T, Hollinsky C, Walter I, Joachim A, Rülicke T. Kolbe T, et al. Surg Endosc. 2010 Feb;24(2):455-61. doi: 10.1007/s00464-009-0596-y. Epub 2009 Jul 2. Surg Endosc. 2010. PMID: 19572177 - Biocompatibility issues with modern implants in bone - a review for clinical orthopedics.
Nuss KM, von Rechenberg B. Nuss KM, et al. Open Orthop J. 2008 Apr 25;2:66-78. doi: 10.2174/1874325000802010066. Open Orthop J. 2008. PMID: 19506701 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous