Estimation of energy expenditure using CSA accelerometers at hip and wrist sites - PubMed (original) (raw)
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
A M Swartz et al. Med Sci Sports Exerc. 2000 Sep.
Abstract
Purpose: This study was designed to establish prediction models that relate hip and wrist accelerometer data to energy expenditure (EE) in field and laboratory settings. We also sought to determine whether the addition of a wrist accelerometer would significantly improve the prediction of EE (METs), compared with a model that used a hip accelerometer alone.
Methods: Seventy participants completed one to six activities within the categories of yardwork, housework, family care, occupation, recreation, and conditioning, for a total of 5 to 12 participants tested per activity. EE was measured using the Cosmed K4b2 portable metabolic system. Simultaneously, two Computer Science and Applications, Inc. (CSA) accelerometers (model 7164), one worn on the wrist and one worn on the hip, recorded body movement. Correlations between EE measured by the Cosmed and the counts recorded by the CSA accelerometers were calculated, and regression equations were developed to predict EE from the CSA data.
Results: The wrist, hip, and combined hip and wrist regression equations accounted for 3.3%, 31.7%, and 34.3% of the variation in EE, respectively. The addition of the wrist accelerometer data to the hip accelerometer data to form a bivariate regression equation, although statistically significant (P = 0.002), resulted in only a minor improvement in prediction of EE. Cut points for 3 METs (574 hip counts), 6 METs (4945 hip counts), and 9 METs (9317 hip counts) were also established.
Conclusion: The small amount of additional accuracy gained from the wrist accelerometer is offset by the extra time required to analyze the data and the cost of the accelerometer.
Similar articles
- A random forest classifier for the prediction of energy expenditure and type of physical activity from wrist and hip accelerometers.
Ellis K, Kerr J, Godbole S, Lanckriet G, Wing D, Marshall S. Ellis K, et al. Physiol Meas. 2014 Nov;35(11):2191-203. doi: 10.1088/0967-3334/35/11/2191. Epub 2014 Oct 23. Physiol Meas. 2014. PMID: 25340969 Free PMC article. - Comparison of linear and non-linear models for predicting energy expenditure from raw accelerometer data.
Montoye AHK, Begum M, Henning Z, Pfeiffer KA. Montoye AHK, et al. Physiol Meas. 2017 Feb;38(2):343-357. doi: 10.1088/1361-6579/38/2/343. Epub 2017 Jan 20. Physiol Meas. 2017. PMID: 28107205 - Validity of four motion sensors in measuring moderate intensity physical activity.
Bassett DR Jr, Ainsworth BE, Swartz AM, Strath SJ, O'Brien WL, King GA. Bassett DR Jr, et al. Med Sci Sports Exerc. 2000 Sep;32(9 Suppl):S471-80. doi: 10.1097/00005768-200009001-00006. Med Sci Sports Exerc. 2000. PMID: 10993417 - The Dilemma of Analyzing Physical Activity and Sedentary Behavior with Wrist Accelerometer Data: Challenges and Opportunities.
Gao Z, Liu W, McDonough DJ, Zeng N, Lee JE. Gao Z, et al. J Clin Med. 2021 Dec 18;10(24):5951. doi: 10.3390/jcm10245951. J Clin Med. 2021. PMID: 34945247 Free PMC article. Review. - Conducting accelerometer-based activity assessments in field-based research.
Trost SG, McIver KL, Pate RR. Trost SG, et al. Med Sci Sports Exerc. 2005 Nov;37(11 Suppl):S531-43. doi: 10.1249/01.mss.0000185657.86065.98. Med Sci Sports Exerc. 2005. PMID: 16294116 Review.
Cited by
- Review of self-reported physical activity assessments for pregnancy: summary of the evidence for validity and reliability.
Evenson KR, Chasan-Taber L, Symons Downs D, Pearce EE. Evenson KR, et al. Paediatr Perinat Epidemiol. 2012 Sep;26(5):479-94. doi: 10.1111/j.1365-3016.2012.01311.x. Epub 2012 Jul 5. Paediatr Perinat Epidemiol. 2012. PMID: 22882792 Free PMC article. Review. - Energy cost of walking in older adults: accuracy of the ActiGraph accelerometer predictive equations.
Ndahimana D, Kim YJ, Wang CS, Kim EK. Ndahimana D, et al. Nutr Res Pract. 2022 Oct;16(5):565-576. doi: 10.4162/nrp.2022.16.5.565. Epub 2021 Dec 27. Nutr Res Pract. 2022. PMID: 36238379 Free PMC article. - Classification accuracy of the wrist-worn gravity estimator of normal everyday activity accelerometer.
Welch WA, Bassett DR, Thompson DL, Freedson PS, Staudenmayer JW, John D, Steeves JA, Conger SA, Ceaser T, Howe CA, Sasaki JE, Fitzhugh EC. Welch WA, et al. Med Sci Sports Exerc. 2013 Oct;45(10):2012-9. doi: 10.1249/MSS.0b013e3182965249. Med Sci Sports Exerc. 2013. PMID: 23584403 Free PMC article. - The influence of aerobic fitness on obesity and its parent-offspring correlations in a cross-sectional study among German families.
Foraita R, Brandes M, Günther F, Bammann K, Pigeot I, Ahrens W. Foraita R, et al. BMC Public Health. 2015 Jul 11;15:638. doi: 10.1186/s12889-015-2013-x. BMC Public Health. 2015. PMID: 26162746 Free PMC article. - Calibrating Physical Activity and Sedentary Behavior for Hip-Worn Accelerometry in Older Women With Two Epoch Lengths: The Women's Health Initiative Objective Physical Activity and Cardiovascular Health Calibration Study.
Evenson KR, Wen F, Moore CC, LaMonte MJ, Lee IM, LaCroix AZ, Di C. Evenson KR, et al. J Meas Phys Behav. 2023 Jun;6(2):156-161. doi: 10.1123/jmpb.2022-0036. Epub 2023 May 9. J Meas Phys Behav. 2023. PMID: 38037607 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical