Image registration by maximization of combined mutual information and gradient information - PubMed (original) (raw)
Comparative Study
doi: 10.1109/42.876307.
Affiliations
- PMID: 11055805
- DOI: 10.1109/42.876307
Comparative Study
Image registration by maximization of combined mutual information and gradient information
J P Pluim et al. IEEE Trans Med Imaging. 2000 Aug.
Abstract
Mutual information has developed into an accurate measure for rigid and affine monomodality and multimodality image registration. The robustness of the measure is questionable, however. A possible reason for this is the absence of spatial information in the measure. The present paper proposes to include spatial information by combining mutual information with a term based on the image gradient of the images to be registered. The gradient term not only seeks to align locations of high gradient magnitude, but also aims for a similar orientation of the gradients at these locations. Results of combining both standard mutual information as well as a normalized measure are presented for rigid registration of three-dimensional clinical images [magnetic resonance (MR), computed tomography (CT), and positron emission tomography (PET)]. The results indicate that the combined measures yield a better registration function does mutual information or normalized mutual information per se. The registration functions are less sensitive to low sampling resolution, do not contain incorrect global maxima that are sometimes found in the mutual information function, and interpolation-induced local minima can be reduced. These characteristics yield the promise of more robust registration measures. The accuracy of the combined measures is similar to that of mutual information-based methods.
Similar articles
- Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners.
Shekhar R, Walimbe V, Raja S, Zagrodsky V, Kanvinde M, Wu G, Bybel B. Shekhar R, et al. J Nucl Med. 2005 Sep;46(9):1488-96. J Nucl Med. 2005. PMID: 16157532 Clinical Trial. - Automatic registration of PET and CT studies for clinical use in thoracic and abdominal conformal radiotherapy.
Rizzo G, Castiglioni I, Arienti R, Cattaneo GM, Landoni C, Artioli D, Gilardi MC, Messa C, Reni M, Ceresoli GL, Fazio F. Rizzo G, et al. Q J Nucl Med Mol Imaging. 2005 Sep;49(3):267-79. Q J Nucl Med Mol Imaging. 2005. PMID: 16172573 - Automatic elastic image registration by interpolation of 3D rotations and translations from discrete rigid-body transformations.
Walimbe V, Shekhar R. Walimbe V, et al. Med Image Anal. 2006 Dec;10(6):899-914. doi: 10.1016/j.media.2006.09.002. Epub 2006 Oct 31. Med Image Anal. 2006. PMID: 17079184 - [Computation of mutual information in medical image registration based on mutual information].
Zhang J, Han G. Zhang J, et al. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008 Feb;25(1):12-7. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008. PMID: 18435247 Chinese. - 3D breast image registration--a review.
Sivaramakrishna R. Sivaramakrishna R. Technol Cancer Res Treat. 2005 Feb;4(1):39-48. doi: 10.1177/153303460500400106. Technol Cancer Res Treat. 2005. PMID: 15649086 Review.
Cited by
- On removing interpolation and resampling artifacts in rigid image registration.
Aganj I, Yeo BT, Sabuncu MR, Fischl B. Aganj I, et al. IEEE Trans Image Process. 2013 Feb;22(2):816-27. doi: 10.1109/TIP.2012.2224356. Epub 2012 Oct 11. IEEE Trans Image Process. 2013. PMID: 23076044 Free PMC article. - Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.
Kim SG, Feng L, Grimm R, Freed M, Block KT, Sodickson DK, Moy L, Otazo R. Kim SG, et al. J Magn Reson Imaging. 2016 Jan;43(1):261-9. doi: 10.1002/jmri.24961. Epub 2015 Jun 1. J Magn Reson Imaging. 2016. PMID: 26032976 Free PMC article. - Registration of Brain MRI/PET Images Based on Adaptive Combination of Intensity and Gradient Field Mutual Information.
Liu J, Tian J. Liu J, et al. Int J Biomed Imaging. 2007;2007:93479. doi: 10.1155/2007/93479. Int J Biomed Imaging. 2007. PMID: 17710255 Free PMC article. - A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy.
Chelikani S, Purushothaman K, Knisely J, Chen Z, Nath R, Bansal R, Duncan J. Chelikani S, et al. Int J Radiat Oncol Biol Phys. 2006 Jun 1;65(2):535-47. doi: 10.1016/j.ijrobp.2005.12.032. Int J Radiat Oncol Biol Phys. 2006. PMID: 16690436 Free PMC article. - Non-rigid MR-TRUS image registration for image-guided prostate biopsy using correlation ratio-based mutual information.
Gong L, Wang H, Peng C, Dai Y, Ding M, Sun Y, Yang X, Zheng J. Gong L, et al. Biomed Eng Online. 2017 Jan 10;16(1):8. doi: 10.1186/s12938-016-0308-5. Biomed Eng Online. 2017. PMID: 28086888 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources