Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs
R Luechinger et al. Pacing Clin Electrophysiol. 2001 Feb.
Abstract
Magnetic resonance imaging (MRI) is a widely accepted tool for the diagnosis of a variety of disease states. However, the presence of an implanted pacemaker is considered to be a strict contraindication to MRI in a vast majority of centers due to safety concerns. In phantom studies, the authors investigated the force and torque effects of the static magnetic field of MRI on pacemakers and ICDs. Thirty-one pacemakers (15 dual chamber and 16 single chamber units) from eight manufacturers and 13 ICDs from four manufacturers were exposed to the static magnetic field of a 1.5-Tesla MRI scanner. Magnetic force and acceleration measurements were obtained quantitatively, and torque measurements were made qualitatively. For pacemakers, the measured magnetic force was in the range of 0.05-3.60 N. Pacemakers released after 1995 had low magnetic force values as compared to the older devices. For these devices, the measured acceleration was even lower than the gravity of the earth (< 9.81 N/kg). Likewise, the torque levels were significantly reduced in newer generation pacemakers (< or = 2 from a scale of 6). ICD devices, except for one recent model, showed higher force (1.03-5.85 N), acceleration 9.5-34.2 N/kg), and torque (5-6 out of 6) levels. In conclusion, modern pacemakers present no safety risk with respect to magnetic force and torque induced by the static magnetic field of a 1.5-Tesla MRI scanner. However, ICD devices, despite considerable reduction in size and weight, may still pose problems due to strong magnetic force and torque.
Similar articles
- Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla.
Shellock FG, Fischer L, Fieno DS. Shellock FG, et al. J Cardiovasc Magn Reson. 2007;9(1):21-31. doi: 10.1080/10976640600897237. J Cardiovasc Magn Reson. 2007. PMID: 17178677 - [Safety of cardiac pacemakers and implantable cardioverter-defibrillators in magnetic resonance imaging. Assessment of the aggregate function at 1.5 tesla].
Nordbeck P, Bauer WR. Nordbeck P, et al. Dtsch Med Wochenschr. 2008 Mar;133(13):624-8. doi: 10.1055/s-2008-1067294. Dtsch Med Wochenschr. 2008. PMID: 18351504 German. - Safety and efficiency of low-field magnetic resonance imaging in patients with cardiac rhythm management devices.
Schukro C, Puchner SB. Schukro C, et al. Eur J Radiol. 2019 Sep;118:96-100. doi: 10.1016/j.ejrad.2019.07.005. Epub 2019 Jul 9. Eur J Radiol. 2019. PMID: 31439265 - Electronic security systems and active implantable medical devices.
Irnich W. Irnich W. Pacing Clin Electrophysiol. 2002 Aug;25(8):1235-58. doi: 10.1046/j.1460-9592.2002.01235.x. Pacing Clin Electrophysiol. 2002. PMID: 12358176 Review. - Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients: how far have we come?
Nordbeck P, Ertl G, Ritter O. Nordbeck P, et al. Eur Heart J. 2015 Jun 21;36(24):1505-11. doi: 10.1093/eurheartj/ehv086. Epub 2015 Mar 21. Eur Heart J. 2015. PMID: 25796053 Free PMC article. Review.
Cited by
- Forces on cardiac implantable electronic devices during remote magnetic navigation.
Jilek C, Lennerz C, Stracke B, Badran H, Semmler V, Reents T, Ammar S, Fichtner S, Haller B, Hessling G, Deisenhofer I, Kolb C. Jilek C, et al. Clin Res Cardiol. 2013 Mar;102(3):185-92. doi: 10.1007/s00392-012-0513-6. Epub 2012 Sep 29. Clin Res Cardiol. 2013. PMID: 23052333 - Global and regional wall motion abnormalities of pacing-induced heart failure assessed by multi-detector row CT: a patient and canine model study.
Tsai IC, Huang JL, Ueng KC, Hung YW, Hung CF, Liao WC, Lei HY, Chen MC, Tsai WL, Chen SA, Chen CC, Fu YC, Ting CT. Tsai IC, et al. Int J Cardiovasc Imaging. 2010 Dec;26(Suppl 2):223-35. doi: 10.1007/s10554-010-9684-2. Epub 2010 Aug 21. Int J Cardiovasc Imaging. 2010. PMID: 20730496 - MRI-conditional pacemakers: current perspectives.
Ferreira AM, Costa F, Tralhão A, Marques H, Cardim N, Adragão P. Ferreira AM, et al. Med Devices (Auckl). 2014 May 7;7:115-24. doi: 10.2147/MDER.S44063. eCollection 2014. Med Devices (Auckl). 2014. PMID: 24851058 Free PMC article. Review. - MRI in patients with cardiac devices.
Martin ET, Sandler DA. Martin ET, et al. Curr Cardiol Rep. 2007 Mar;9(1):63-71. doi: 10.1007/s11886-007-0012-y. Curr Cardiol Rep. 2007. PMID: 17362687 Review. - Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison.
Avery R, Day K, Jokerst C, Kazui T, Krupinski E, Khalpey Z. Avery R, et al. J Cardiothorac Surg. 2017 Oct 10;12(1):89. doi: 10.1186/s13019-017-0652-y. J Cardiothorac Surg. 2017. PMID: 29017566 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical