We report on the design and application of a high-efficiency multiple-capillary liquid chromatography (LC) system for high-throughput proteome analysis. The multiple-capillary LC system using commercial LC pumps was operated at a pressure of 10,000 psi to deliver mobile phases through a novel passive feedback valve arrangement that permitted mobile-phase flow path switching and efficient sample introduction. The multiple-capillary LC system uses several serially connected dual-capillary column devices. The dual-capillary column approach eliminates the time delays for column regeneration (or equilibration) since one capillary column was used for a separation while the other was being washed. Several serially connected dual-capillary columns and electrospray ionization (ESI) sources were operated independently and can be used either for "backup" operation or for parallel operation with other mass spectrometers. This high-efficiency multiple-capillary LC system utilizes switching valves for all operations, enabling automated operation. The separation efficiency of the dual-capillary column arrangement, optimal capillary dimensions (column length and packed particle size), capillary regeneration conditions, and mobile-phase compositions and their compatibility with electrospray ionization were investigated. A high magnetic field (11.4 T) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was coupled on-line with this high-efficiency multiple-capillary LC system using an ESI interface. The capillary LC provided a peak capacity of approximately 650, and the 2-D capillary LC-FTICR analysis provided a combined resolving power of > 6 x 10(7) components. For yeast cytosolic tryptic digests > 100,000 polypeptides were detected, and approximately 1,000 proteins could be characterized from a single capillary LC-FTICR analysis using the high mass measurement accuracy (approximately 1 ppm) of FTICR, and likely more if LC retention time information were also exploited for peptide identification.
Similar articles
- Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics.
Shen Y, Zhao R, Belov ME, Conrads TP, Anderson GA, Tang K, Pasa-Tolić L, Veenstra TD, Lipton MS, Udseth HR, Smith RD. Shen Y, et al. Anal Chem. 2001 Apr 15;73(8):1766-75. doi: 10.1021/ac0011336. Anal Chem. 2001. PMID: 11338590 - Forced degradation and impurity profiling: recent trends in analytical perspectives.
Jain D, Basniwal PK. Jain D, et al. J Pharm Biomed Anal. 2013 Dec;86:11-35. doi: 10.1016/j.jpba.2013.07.013. Epub 2013 Jul 31. J Pharm Biomed Anal. 2013. PMID: 23969330 Review. - Screening of synthetic PDE-5 inhibitors and their analogues as adulterants: analytical techniques and challenges.
Patel DN, Li L, Kee CL, Ge X, Low MY, Koh HL. Patel DN, et al. J Pharm Biomed Anal. 2014 Jan;87:176-90. doi: 10.1016/j.jpba.2013.04.037. Epub 2013 May 6. J Pharm Biomed Anal. 2014. PMID: 23721687 Review.
Cited by
- An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies.
Baker ES, Livesay EA, Orton DJ, Moore RJ, Danielson WF 3rd, Prior DC, Ibrahim YM, LaMarche BL, Mayampurath AM, Schepmoes AA, Hopkins DF, Tang K, Smith RD, Belov ME. Baker ES, et al. J Proteome Res. 2010 Feb 5;9(2):997-1006. doi: 10.1021/pr900888b. J Proteome Res. 2010. PMID: 20000344 Free PMC article. - Accurate mass measurements in proteomics.
Liu T, Belov ME, Jaitly N, Qian WJ, Smith RD. Liu T, et al. Chem Rev. 2007 Aug;107(8):3621-53. doi: 10.1021/cr068288j. Epub 2007 Jul 25. Chem Rev. 2007. PMID: 17649984 Free PMC article. Review. No abstract available. - Sub part-per-million mass accuracy by using stepwise-external calibration in fourier transform ion cyclotron resonance mass spectrometry.
Wong RL, Amster IJ. Wong RL, et al. J Am Soc Mass Spectrom. 2006 Dec;17(12):1681-91. doi: 10.1016/j.jasms.2006.07.019. Epub 2006 Aug 24. J Am Soc Mass Spectrom. 2006. PMID: 16934995 - Phosphate-containing polyethylene glycol polymers prevent lethal sepsis by multidrug-resistant pathogens.
Zaborin A, Defazio JR, Kade M, Kaiser BL, Belogortseva N, Camp DG 2nd, Smith RD, Adkins JN, Kim SM, Alverdy A, Goldfeld D, Firestone MA, Collier JH, Jabri B, Tirrell M, Zaborina O, Alverdy JC. Zaborin A, et al. Antimicrob Agents Chemother. 2014;58(2):966-77. doi: 10.1128/AAC.02183-13. Epub 2013 Nov 25. Antimicrob Agents Chemother. 2014. PMID: 24277029 Free PMC article. - Progress in Top-Down Proteomics and the Analysis of Proteoforms.
Toby TK, Fornelli L, Kelleher NL. Toby TK, et al. Annu Rev Anal Chem (Palo Alto Calif). 2016 Jun 12;9(1):499-519. doi: 10.1146/annurev-anchem-071015-041550. Annu Rev Anal Chem (Palo Alto Calif). 2016. PMID: 27306313 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Molecular Biology Databases