Alignment error envelopes for single particle analysis
G J Jensen. J Struct Biol. 2001 Feb-Mar.
Abstract
To determine the structure of a biological particle to high resolution by electron microscopy, image averaging is required to combine information from different views and to increase the signal-to-noise ratio. Starting from the number of noiseless views necessary to resolve features of a given size, four general factors are considered that increase the number of images actually needed: (1) the physics of electron scattering introduces shot noise, (2) thermal motion and particle inhomogeneity cause the scattered electrons to describe a mixture of structures, (3) the microscope system fails to usefully record all the information carried by the scattered electrons, and (4) image misalignment leads to information loss through incoherent averaging. The compound effect of factors 2-4 is approximated by the product of envelope functions. The problem of incoherent image averaging is developed in detail through derivation of five envelope functions that account for small errors in 11 "alignment" parameters describing particle location, orientation, defocus, magnification, and beam tilt. The analysis provides target error tolerances for single particle analysis to near-atomic (3.5 A) resolution, and this prospect is shown to depend critically on image quality, defocus determination, and microscope alignment.
Copyright 2001 Academic Press.
Similar articles
- Fourier amplitude decay of electron cryomicroscopic images of single particles and effects on structure determination.
Saad A, Ludtke SJ, Jakana J, Rixon FJ, Tsuruta H, Chiu W. Saad A, et al. J Struct Biol. 2001 Jan;133(1):32-42. doi: 10.1006/jsbi.2001.4330. J Struct Biol. 2001. PMID: 11356062 - Advantages of CCD detectors for de novo three-dimensional structure determination in single-particle electron microscopy.
Sander B, Golas MM, Stark H. Sander B, et al. J Struct Biol. 2005 Jul;151(1):92-105. doi: 10.1016/j.jsb.2005.04.004. J Struct Biol. 2005. PMID: 15946861 - Obtaining high-resolution images of biological macromolecules by using a cryo-electron microscope with a liquid-helium cooled stage.
Mitsuoka K. Mitsuoka K. Micron. 2011 Feb;42(2):100-6. doi: 10.1016/j.micron.2010.08.006. Epub 2010 Sep 8. Micron. 2011. PMID: 20869255 Review. - The resolution dependence of optimal exposures in liquid nitrogen temperature electron cryomicroscopy of catalase crystals.
Baker LA, Smith EA, Bueler SA, Rubinstein JL. Baker LA, et al. J Struct Biol. 2010 Mar;169(3):431-7. doi: 10.1016/j.jsb.2009.11.014. Epub 2009 Dec 1. J Struct Biol. 2010. PMID: 19958834 - Review: automatic particle detection in electron microscopy.
Nicholson WV, Glaeser RM. Nicholson WV, et al. J Struct Biol. 2001 Feb-Mar;133(2-3):90-101. doi: 10.1006/jsbi.2001.4348. J Struct Biol. 2001. PMID: 11472081 Review.
Cited by
- Challenges in solving structures from radiation-damaged tomograms of protein nanocrystals assessed by simulation.
Peck A, Yao Q, Brewster AS, Zwart PH, Heumann JM, Sauter NK, Jensen GJ. Peck A, et al. Acta Crystallogr D Struct Biol. 2021 May 1;77(Pt 5):572-586. doi: 10.1107/S2059798321002369. Epub 2021 Apr 14. Acta Crystallogr D Struct Biol. 2021. PMID: 33950014 Free PMC article. - Enhancing the signal-to-noise ratio and generating contrast for cryo-EM images with convolutional neural networks.
Palovcak E, Asarnow D, Campbell MG, Yu Z, Cheng Y. Palovcak E, et al. IUCrJ. 2020 Oct 24;7(Pt 6):1142-1150. doi: 10.1107/S2052252520013184. eCollection 2020 Nov 1. IUCrJ. 2020. PMID: 33209325 Free PMC article. - Non-uniformity of projection distributions attenuates resolution in Cryo-EM.
Baldwin PR, Lyumkis D. Baldwin PR, et al. Prog Biophys Mol Biol. 2020 Jan;150:160-183. doi: 10.1016/j.pbiomolbio.2019.09.002. Epub 2019 Sep 13. Prog Biophys Mol Biol. 2020. PMID: 31525386 Free PMC article. - Estimating the effect of finite depth of field in single-particle cryo-EM.
Downing KH, Glaeser RM. Downing KH, et al. Ultramicroscopy. 2018 Jan;184(Pt A):94-99. doi: 10.1016/j.ultramic.2017.08.007. Epub 2017 Aug 19. Ultramicroscopy. 2018. PMID: 28869854 Free PMC article. - Design of a molecular support for cryo-EM structure determination.
Martin TG, Bharat TA, Joerger AC, Bai XC, Praetorius F, Fersht AR, Dietz H, Scheres SH. Martin TG, et al. Proc Natl Acad Sci U S A. 2016 Nov 22;113(47):E7456-E7463. doi: 10.1073/pnas.1612720113. Epub 2016 Nov 7. Proc Natl Acad Sci U S A. 2016. PMID: 27821763 Free PMC article.