Abstract
Records of pulpal blood flow obtained from human teeth with a laser Doppler flowmeter include a very large component derived from periodontal and other tissues outside the pulp, but this contamination can be reduced by covering the surrounding tissues with opaque rubber dam. The present experiments were carried out to determine what proportion of the signal obtained with this dam in place is derived from non-pulpal tissues. Recordings were made from 22 healthy, intact upper incisors in 14 individuals (aged 22-40 years) with and without dam under the following conditions: from the intact teeth, after local anaesthesia (LA) and the preparation of a deep cavity in the incisal third of the labial surface of the tooth, and after removal of the pulp and arrest of bleeding. In some cases, a reading was also made after replacing the pulp in the pulp cavity. The rubber dam reduced significantly (P<0.05) the mean blood flow reading from the intact teeth by 73%, from 6.98 arbitrary perfusion units (PU) (+/-1.30 S.D., n=22) to 1.92+/-1.50 PU. After LA and cavity preparation, the mean signal with dam was 1.45+/-0.61 PU (n=16). This fell significantly by 76% to 0.35+/-0.19 PU (n=16) when the pulp was removed but not replaced, and by 43% to 0.98+/-0.36 PU (n=14) when the pulp was removed and replaced in the pulp cavity. The latter condition is thought to reproduce most closely the scattering of light in an intact tooth. The results confirm previous findings that up to 80% of the laser Doppler blood-flow signal recorded from an intact human tooth without rubber dam is of non-pulpal origin. They also show that only approximately 43% of the signal recorded with an opaque rubber dam is from pulp.
Similar articles
- Pulpal blood flow recorded from human premolar teeth with a laser Doppler flow meter using either red or infrared light.
Kijsamanmith K, Timpawat S, Vongsavan N, Matthews B. Kijsamanmith K, et al. Arch Oral Biol. 2011 Jul;56(7):629-33. doi: 10.1016/j.archoralbio.2010.12.003. Epub 2011 Jan 5. Arch Oral Biol. 2011. PMID: 21211791 - A comparison between red and infrared light for recording pulpal blood flow from human anterior teeth with a laser Doppler flow meter.
Kijsamanmith K, Timpawat S, Vongsavan N, Matthews B. Kijsamanmith K, et al. Arch Oral Biol. 2011 Jun;56(6):614-8. doi: 10.1016/j.archoralbio.2011.02.010. Epub 2011 Mar 12. Arch Oral Biol. 2011. PMID: 21397892 - Pulpal blood flow recorded from exposed dentine with a laser Doppler flow meter using red or infrared light.
Kijsamanmith K, Vongsavan N, Matthews B. Kijsamanmith K, et al. Arch Oral Biol. 2018 Mar;87:163-167. doi: 10.1016/j.archoralbio.2017.12.009. Epub 2017 Dec 16. Arch Oral Biol. 2018. PMID: 29304423 - Effect of tooth isolation on laser Doppler readings.
Setzer FC, Challagulla P, Kataoka SH, Trope M. Setzer FC, et al. Int Endod J. 2013 Jun;46(6):517-22. doi: 10.1111/iej.12019. Epub 2012 Nov 22. Int Endod J. 2013. PMID: 23173723 - Microvascular architecture and exchange in teeth.
Matthews B, Andrew D. Matthews B, et al. Microcirculation. 1995 Dec;2(4):305-13. doi: 10.3109/10739689509148275. Microcirculation. 1995. PMID: 8714812 Review.
Cited by
- Pulp Vitality Diagnosis by Means of an Optical Pulp Scanning Device.
Briseño Marroquín B, Borgschulte M, Savic A, Ertl TP, Wolf TG. Briseño Marroquín B, et al. Dent J (Basel). 2024 Oct 12;12(10):326. doi: 10.3390/dj12100326. Dent J (Basel). 2024. PMID: 39452454 Free PMC article. - Leveling the curve of Spee using different sized archwires: a randomized clinical trial of blood flow changes.
Ba-Hattab R, Abu Alhaija ES, Nasrawi YH, Taha N, Daher H, Daher S. Ba-Hattab R, et al. Clin Oral Investig. 2023 Jun;27(6):2943-2955. doi: 10.1007/s00784-023-04894-7. Epub 2023 Feb 11. Clin Oral Investig. 2023. PMID: 36773128 Free PMC article. Clinical Trial. - Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial.
Alhaija ESA, Shahin AY, Badran SA, Daher SO, Daher HO. Alhaija ESA, et al. J Appl Oral Sci. 2021 Oct 4;29:e20210089. doi: 10.1590/1678-7757-2021-0089. eCollection 2021. J Appl Oral Sci. 2021. PMID: 34614121 Free PMC article. - Detection of pulsed blood flow through a molar pulp chamber and surrounding tissue in vitro.
Knörzer S, Hiller KA, Brandt M, Niklas A, Putzger J, Monkman GJ, Danilov SN, Ganichev SD, Schulz I, Schmalz G. Knörzer S, et al. Clin Oral Investig. 2019 Mar;23(3):1121-1132. doi: 10.1007/s00784-018-2530-y. Epub 2018 Jun 29. Clin Oral Investig. 2019. PMID: 29959598 - Diurnal variations and pulpal status: is there a need for FFT besides LDF?
Roeykens HJJ, De Moor RJG. Roeykens HJJ, et al. Lasers Med Sci. 2018 Dec;33(9):1891-1900. doi: 10.1007/s10103-018-2550-5. Epub 2018 Jun 13. Lasers Med Sci. 2018. PMID: 29948454
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources