ANOMALOUS RECTIFICATION IN THE SQUID GIANT AXON INJECTED WITH TETRAETHYLAMMONIUM CHLORIDE - PubMed (original) (raw)

ANOMALOUS RECTIFICATION IN THE SQUID GIANT AXON INJECTED WITH TETRAETHYLAMMONIUM CHLORIDE

C M ARMSTRONG et al. J Gen Physiol. 1965 May.

Abstract

The injection of tetraethylammonium chloride into the giant axon of the squid prolongs the action potential and eliminates most of the late current under voltage-clamp. Experiments on fibers in an external medium of high potassium ion concentration demonstrate that injected tetraethylammonium chloride causes rectification of the instantaneous current-voltage curve for potassium by excluding outward current. This interference with the flow of outward potassium ion current underlies the prolongation of the action potential seen in tetraethylammonium-injected fibers.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Aust J Exp Biol Med Sci. 1961 Jun;39:275-93 - PubMed
    1. J Physiol. 1952 Apr;116(4):449-72 - PubMed
    1. J Physiol. 1959 Oct;148:306-31 - PubMed
    1. J Physiol. 1959 Oct;148:127-60 - PubMed
    1. J Gen Physiol. 1960 Sep;44:123-67 - PubMed

MeSH terms

Substances

LinkOut - more resources