The application of implant technology for cybernetic systems
Kevin Warwick et al. Arch Neurol. 2003 Oct.
Abstract
Objective: To assess the usefulness, compatibility, and long-term operability of a microelectrode array into the median nerve of the left arm of a healthy volunteer, including perception of feedback stimulation and operation of an instrumented prosthetic hand.
Setting: The study was carried out from March 14 through June 18, 2002, in England and the United States.
Results: The blindfolded subject received feedback information, obtained from force and slip sensors on the prosthetic hand, and subsequently used the implanted device to control the hand by applying an appropriate force to grip an unseen object. Operability was also demonstrated remotely via the Internet, with the subject in New York, NY, and the prosthetic hand in Reading, England. Finally, the subject was able to control an electric wheelchair, via decoded signals from the implant device, to select the direction of travel by opening and closing his hand. The implantation did not result in infection or any perceivable loss of hand sensation or motion control. The implant was finally extracted because of mechanical fatigue of the percutaneous connection. Further testing after extraction has not indicated any measurable long-term defects in the subject.
Conclusions: This implant may allow recipients to have abilities they would otherwise not possess. The response to stimulation improved considerably during the trial, suggesting that the subject learned to process the incoming information more effectively.
Similar articles
- Direct neural sensory feedback and control of a prosthetic arm.
Dhillon GS, Horch KW. Dhillon GS, et al. IEEE Trans Neural Syst Rehabil Eng. 2005 Dec;13(4):468-72. doi: 10.1109/TNSRE.2005.856072. IEEE Trans Neural Syst Rehabil Eng. 2005. PMID: 16425828 Clinical Trial. - How predictive is grip force control in the complete absence of somatosensory feedback?
Nowak DA, Glasauer S, Hermsdorfer J. Nowak DA, et al. Brain. 2004 Jan;127(Pt 1):182-92. doi: 10.1093/brain/awh016. Epub 2003 Oct 21. Brain. 2004. PMID: 14570822 - Different modes of grip force control: voluntary and externally guided arm movements with a hand-held load.
Nowak DA. Nowak DA. Clin Neurophysiol. 2004 Apr;115(4):839-48. doi: 10.1016/j.clinph.2003.11.031. Clin Neurophysiol. 2004. PMID: 15003764 - Artificial vision: needs, functioning, and testing of a retinal electronic prosthesis.
Chader GJ, Weiland J, Humayun MS. Chader GJ, et al. Prog Brain Res. 2009;175:317-32. doi: 10.1016/S0079-6123(09)17522-2. Prog Brain Res. 2009. PMID: 19660665 Review. - Extended physiologic taction: design and evaluation of a proportional force feedback system.
Meek SG, Jacobsen SC, Goulding PP. Meek SG, et al. J Rehabil Res Dev. 1989 Summer;26(3):53-62. J Rehabil Res Dev. 1989. PMID: 2666644 Review.
Cited by
- Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses.
Ledbetter NM, Ethier C, Oby ER, Hiatt SD, Wilder AM, Ko JH, Agnew SP, Miller LE, Clark GA. Ledbetter NM, et al. J Neurophysiol. 2013 Jan;109(2):580-90. doi: 10.1152/jn.00688.2011. Epub 2012 Oct 17. J Neurophysiol. 2013. PMID: 23076108 Free PMC article. - Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.
Tan DW, Schiefer MA, Keith MW, Anderson JR, Tyler DJ. Tan DW, et al. J Neural Eng. 2015 Apr;12(2):026002. doi: 10.1088/1741-2560/12/2/026002. Epub 2015 Jan 28. J Neural Eng. 2015. PMID: 25627310 Free PMC article. - Neuroengineering and neuroprosthetics.
Warwick K. Warwick K. Brain Neurosci Adv. 2018 Dec 12;2:2398212818817499. doi: 10.1177/2398212818817499. eCollection 2018 Jan-Dec. Brain Neurosci Adv. 2018. PMID: 32166170 Free PMC article. Review. - The Evolution of Neuroprosthetic Interfaces.
Adewole DO, Serruya MD, Harris JP, Burrell JC, Petrov D, Chen HI, Wolf JA, Cullen DK. Adewole DO, et al. Crit Rev Biomed Eng. 2016;44(1-2):123-52. doi: 10.1615/CritRevBiomedEng.2016017198. Crit Rev Biomed Eng. 2016. PMID: 27652455 Free PMC article. Review. - Discrimination and Recognition of Phantom Finger Sensation Through Transcutaneous Electrical Nerve Stimulation.
Li M, Zhang D, Chen Y, Chai X, He L, Chen Y, Guo J, Sui X. Li M, et al. Front Neurosci. 2018 Apr 30;12:283. doi: 10.3389/fnins.2018.00283. eCollection 2018. Front Neurosci. 2018. PMID: 29760647 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical