Amperometric detection in TMB/HRP-based assays - PubMed (original) (raw)
. 2005 May;382(2):297-302.
doi: 10.1007/s00216-005-3084-9. Epub 2005 May 13.
Affiliations
- PMID: 15891870
- DOI: 10.1007/s00216-005-3084-9
Amperometric detection in TMB/HRP-based assays
Pablo Fanjul-Bolado et al. Anal Bioanal Chem. 2005 May.
Abstract
3,3',5,5'-Tetramethylbenzidine (TMB) is the most commonly used chromogen for horseradish peroxidase (HRP) and so its performance as an electrochemical substrate was evaluated. Measurements of HRP activity in solution were carried out by using an amperometric detector coupled to a flow injection analysis (FIA) system. The enzymatic product was easily detected at a potential of +0.1 V (vs. Ag-pseudoreference electrode) at a bare screen-printed electrode placed in a homemade electrochemical flow cell. A high flow rate (4.3 mL min(-1)) of 0.5 M H2SO4 was used to obtain repeatable signals and a short analysis time. The detection limit achieved after 15 min of incubation was 2x10(-14) M of HRP. The applicability of the amperometric detector to ELISAs was demonstrated by using a commercially available kit for the quantification of interleukin-6 (IL-6) without modifying the kit manufacturer's protocol or the reagents for this test.
Similar articles
- Electrochemical biotin detection based on magnetic beads and a new magnetic flow cell for screen printed electrode.
Biscay J, González García MB, Costa García A. Biscay J, et al. Talanta. 2015 Jan;131:706-11. doi: 10.1016/j.talanta.2014.08.013. Epub 2014 Aug 27. Talanta. 2015. PMID: 25281162 - Flow screen-printed amperometric detection of p-nitrophenol in alkaline phosphatase-based assays.
Fanjul-Bolado P, González-García MB, Costa-García A. Fanjul-Bolado P, et al. Anal Bioanal Chem. 2006 Aug;385(7):1202-8. doi: 10.1007/s00216-006-0367-8. Epub 2006 Mar 11. Anal Bioanal Chem. 2006. PMID: 16532307 - Development of screen-printed electrode based immunosensor for the detection of HER2 antigen in human serum samples.
Tallapragada SD, Layek K, Mukherjee R, Mistry KK, Ghosh M. Tallapragada SD, et al. Bioelectrochemistry. 2017 Dec;118:25-30. doi: 10.1016/j.bioelechem.2017.06.009. Epub 2017 Jun 30. Bioelectrochemistry. 2017. PMID: 28692846 - Quantitative detection of human tumor necrosis factor α by a resonance raman enzyme-linked immunosorbent assay.
Laing S, Hernandez-Santana A, Sassmannshausen J, Asquith DL, McInnes IB, Faulds K, Graham D. Laing S, et al. Anal Chem. 2011 Jan 1;83(1):297-302. doi: 10.1021/ac1024039. Epub 2010 Dec 1. Anal Chem. 2011. PMID: 21121688
Cited by
- Detection of Few Hydrogen Peroxide Molecules Using Self-Reporting Fluorescent Nanodiamond Quantum Sensors.
Wu Y, Balasubramanian P, Wang Z, Coelho JAS, Prslja M, Siebert R, Plenio MB, Jelezko F, Weil T. Wu Y, et al. J Am Chem Soc. 2022 Jul 20;144(28):12642-12651. doi: 10.1021/jacs.2c01065. Epub 2022 Jun 23. J Am Chem Soc. 2022. PMID: 35737900 Free PMC article. - Rapid detection of Salmonella enterica serotype Typhimurium in large volume samples using porous electrodes in a flow-through, enzyme-amplified immunoelectrochemical sensor.
Capobianco JA, Lee J, Armstrong CM, Gehring AG. Capobianco JA, et al. Anal Bioanal Chem. 2019 Aug;411(20):5233-5242. doi: 10.1007/s00216-019-01901-3. Epub 2019 May 24. Anal Bioanal Chem. 2019. PMID: 31127336 Free PMC article. - Sensitive electrochemical immunosensor based on three-dimensional nanostructure gold electrode.
Zhong G, Lan R, Zhang W, Fu F, Sun Y, Peng H, Chen T, Cai Y, Liu A, Lin J, Lin X. Zhong G, et al. Int J Nanomedicine. 2015 Mar 19;10:2219-28. doi: 10.2147/IJN.S76200. eCollection 2015. Int J Nanomedicine. 2015. PMID: 25834434 Free PMC article. - Use of electrochemical DNA biosensors for rapid molecular identification of uropathogens in clinical urine specimens.
Liao JC, Mastali M, Gau V, Suchard MA, Møller AK, Bruckner DA, Babbitt JT, Li Y, Gornbein J, Landaw EM, McCabe ER, Churchill BM, Haake DA. Liao JC, et al. J Clin Microbiol. 2006 Feb;44(2):561-70. doi: 10.1128/JCM.44.2.561-570.2006. J Clin Microbiol. 2006. PMID: 16455913 Free PMC article. - An Ultrasensitive and Selective Determination of Cadmium Ions at ppt Level Using an Enzymic Membrane with Colorimetric and Electrochemical Detection.
Attaallah R, Amine A. Attaallah R, et al. Biosensors (Basel). 2022 May 7;12(5):310. doi: 10.3390/bios12050310. Biosensors (Basel). 2022. PMID: 35624611 Free PMC article.
Publication types