Ewald sphere correction for single-particle electron microscopy - PubMed (original) (raw)
Ewald sphere correction for single-particle electron microscopy
Matthias Wolf et al. Ultramicroscopy. 2006 Mar.
Abstract
Most algorithms for three-dimensional (3D) reconstruction from electron micrographs assume that images correspond to projections of the 3D structure. This approximation limits the attainable resolution of the reconstruction when the dimensions of the structure exceed the depth of field of the microscope. We have developed two methods to calculate a reconstruction that corrects for the depth of field. Either method applied to synthetic data representing a large virus yields a higher resolution reconstruction than a method lacking this correction.
Similar articles
- High-resolution single-particle orientation refinement based on spectrally self-adapting common lines.
Elmlund D, Elmlund H. Elmlund D, et al. J Struct Biol. 2009 Jul;167(1):83-94. doi: 10.1016/j.jsb.2009.04.009. Epub 2009 May 3. J Struct Biol. 2009. PMID: 19410651 - Symmetry-adapted spherical harmonics method for high-resolution 3D single-particle reconstructions.
Liu H, Cheng L, Zeng S, Cai C, Zhou ZH, Yang Q. Liu H, et al. J Struct Biol. 2008 Jan;161(1):64-73. doi: 10.1016/j.jsb.2007.09.016. Epub 2007 Oct 1. J Struct Biol. 2008. PMID: 17977017 - 3D reconstruction from 2D crystal image and diffraction data.
Schenk AD, Castaño-Díez D, Gipson B, Arheit M, Zeng X, Stahlberg H. Schenk AD, et al. Methods Enzymol. 2010;482:101-29. doi: 10.1016/S0076-6879(10)82004-X. Methods Enzymol. 2010. PMID: 20888959 - Three-dimensional reconstruction of single particles from random and nonrandom tilt series.
Radermacher M. Radermacher M. J Electron Microsc Tech. 1988 Aug;9(4):359-94. doi: 10.1002/jemt.1060090405. J Electron Microsc Tech. 1988. PMID: 3058896 Review. - Comparison of single-particle analysis and electron tomography approaches: an overview.
Jonić S, Sorzano CO, Boisset N. Jonić S, et al. J Microsc. 2008 Dec;232(3):562-79. doi: 10.1111/j.1365-2818.2008.02119.x. J Microsc. 2008. PMID: 19094041 Review.
Cited by
- CryoEM single particle reconstruction with a complex-valued particle stack.
Bromberg R, Guo Y, Borek D, Otwinowski Z. Bromberg R, et al. J Struct Biol. 2023 Jun;215(2):107945. doi: 10.1016/j.jsb.2023.107945. Epub 2023 Mar 6. J Struct Biol. 2023. PMID: 36889560 Free PMC article. - Pushing the resolution limit by correcting the Ewald sphere effect in single-particle Cryo-EM reconstructions.
Zhu D, Wang X, Fang Q, Van Etten JL, Rossmann MG, Rao Z, Zhang X. Zhu D, et al. Nat Commun. 2018 Apr 19;9(1):1552. doi: 10.1038/s41467-018-04051-9. Nat Commun. 2018. PMID: 29674632 Free PMC article. - How good can cryo-EM become?
Glaeser RM. Glaeser RM. Nat Methods. 2016 Jan;13(1):28-32. doi: 10.1038/nmeth.3695. Nat Methods. 2016. PMID: 26716559 - Cryomicroscopy in situ: what is the smallest molecule that can be directly identified without labels in a cell?
Russo CJ, Dickerson JL, Naydenova K. Russo CJ, et al. Faraday Discuss. 2022 Nov 8;240(0):277-302. doi: 10.1039/d2fd00076h. Faraday Discuss. 2022. PMID: 35913392 Free PMC article. - Cryo-electron Microscopy of Adeno-associated Virus.
Stagg SM, Yoshioka C, Davulcu O, Chapman MS. Stagg SM, et al. Chem Rev. 2022 Sep 14;122(17):14018-14054. doi: 10.1021/acs.chemrev.1c00936. Epub 2022 May 16. Chem Rev. 2022. PMID: 35575684 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources