Evidence of bias and variation in diagnostic accuracy studies - PubMed (original) (raw)
Evidence of bias and variation in diagnostic accuracy studies
Anne W S Rutjes et al. CMAJ. 2006.
Abstract
Background: Studies with methodologic shortcomings can overestimate the accuracy of a medical test. We sought to determine and compare the direction and magnitude of the effects of a number of potential sources of bias and variation in studies on estimates of diagnostic accuracy.
Methods: We identified meta-analyses of the diagnostic accuracy of tests through an electronic search of the databases MEDLINE, EMBASE, DARE and MEDION (1999-2002). We included meta-analyses with at least 10 primary studies without preselection based on design features. Pairs of reviewers independently extracted study characteristics and original data from the primary studies. We used a multivariable meta-epidemiologic regression model to investigate the direction and strength of the association between 15 study features on estimates of diagnostic accuracy.
Results: We selected 31 meta-analyses with 487 primary studies of test evaluations. Only 1 study had no design deficiencies. The quality of reporting was poor in most of the studies. We found significantly higher estimates of diagnostic accuracy in studies with nonconsecutive inclusion of patients (relative diagnostic odds ratio [RDOR] 1.5, 95% confidence interval [CI] 1.0-2.1) and retrospective data collection (RDOR 1.6, 95% CI 1.1-2.2). The estimates were highest in studies that had severe cases and healthy controls (RDOR 4.9, 95% CI 0.6-37.3). Studies that selected patients based on whether they had been referred for the index test, rather than on clinical symptoms, produced significantly lower estimates of diagnostic accuracy (RDOR 0.5, 95% CI 0.3-0.9). The variance between meta-analyses of the effect of design features was large to moderate for type of design (cohort v. case-control), the use of composite reference standards and the use of differential verification; the variance was close to zero for the other design features.
Interpretation: Shortcomings in study design can affect estimates of diagnostic accuracy, but the magnitude of the effect may vary from one situation to another. Design features and clinical characteristics of patient groups should be carefully considered by researchers when designing new studies and by readers when appraising the results of such studies. Unfortunately, incomplete reporting hampers the evaluation of potential sources of bias in diagnostic accuracy studies.
Figures
Fig. 1: Process of selecting and assessing systematic reviews and primary studies of the accuracy of diagnostic tests. *Exclusion criteria can overlap.
Fig. 2: Effects of study design characteristics on estimates of diagnostic accuracy. RDOR = relative diagnostic odds ratio (adjusted RDORs were estimated in a multivariable random-effects meta-epidemiologic regression model).
Comment in
- Sources of bias in diagnostic accuracy studies and the diagnostic process.
Furukawa TA, Guyatt GH. Furukawa TA, et al. CMAJ. 2006 Feb 14;174(4):481-2. doi: 10.1503/cmaj.060014. CMAJ. 2006. PMID: 16477059 Free PMC article. No abstract available.
Similar articles
- Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer JG, Mol BW, Heisterkamp S, Bonsel GJ, Prins MH, van der Meulen JH, Bossuyt PM. Lijmer JG, et al. JAMA. 1999 Sep 15;282(11):1061-6. doi: 10.1001/jama.282.11.1061. JAMA. 1999. PMID: 10493205 - [Methodological bias and variation of systematic reviews on diagnostic test accuracy].
Li ZX, Yang ZR, Xiang X, Gao P, Shu Z, Huang YS, Cao Y, Sun F, Zhan SY. Li ZX, et al. Zhonghua Liu Xing Bing Xue Za Zhi. 2016 Feb;37(2):286-90. doi: 10.3760/cma.j.issn.0254-6450.2016.02.027. Zhonghua Liu Xing Bing Xue Za Zhi. 2016. PMID: 26917532 Chinese. - Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative.
Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Lijmer JG, Moher D, Rennie D, de Vet HC; STARD group. Bossuyt PM, et al. Clin Chem Lab Med. 2003 Jan;41(1):68-73. doi: 10.1515/CCLM.2003.012. Clin Chem Lab Med. 2003. PMID: 12636052 - Toward complete and accurate reporting of studies of diagnostic accuracy. The STARD initiative.
Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Lijmer JG, Moher D, Rennie D, de Vet HC; Standards for Reporting of Diagnostic Accuracy. Bossuyt PM, et al. Am J Clin Pathol. 2003 Jan;119(1):18-22. doi: 10.1309/8EXC-CM6Y-R1TH-UBAF. Am J Clin Pathol. 2003. PMID: 12520693 Review. - Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Lijmer JG, Moher D, Rennie D, de Vet HC; Standards for Reporting of Diagnostic Accuracy. Bossuyt PM, et al. Radiology. 2003 Jan;226(1):24-8. doi: 10.1148/radiol.2261021292. Radiology. 2003. PMID: 12511664 Review.
Cited by
- Classification and regression tree (CART) model to predict pulmonary tuberculosis in hospitalized patients.
Aguiar FS, Almeida LL, Ruffino-Netto A, Kritski AL, Mello FC, Werneck GL. Aguiar FS, et al. BMC Pulm Med. 2012 Aug 7;12:40. doi: 10.1186/1471-2466-12-40. BMC Pulm Med. 2012. PMID: 22871182 Free PMC article. - Performance characteristics and costs of serological tests for brucellosis in a pastoralist community of northern Tanzania.
Lukambagire AS, Mendes ÂJ, Bodenham RF, McGiven JA, Mkenda NA, Mathew C, Rubach MP, Sakasaka P, Shayo DD, Maro VP, Shirima GM, Thomas KM, Kasanga CJ, Kazwala RR, Halliday JEB, Mmbaga BT. Lukambagire AS, et al. Sci Rep. 2021 Mar 9;11(1):5480. doi: 10.1038/s41598-021-82906-w. Sci Rep. 2021. PMID: 33750848 Free PMC article. - The value of predicting restriction of fetal growth and compromise of its wellbeing: Systematic quantitative overviews (meta-analysis) of test accuracy literature.
Morris RK, Khan KS, Coomarasamy A, Robson SC, Kleijnen J. Morris RK, et al. BMC Pregnancy Childbirth. 2007 Mar 8;7:3. doi: 10.1186/1471-2393-7-3. BMC Pregnancy Childbirth. 2007. PMID: 17346337 Free PMC article. - Transvaginal sonographic cervical length for the prediction of spontaneous preterm birth in twin pregnancies: a systematic review and metaanalysis.
Conde-Agudelo A, Romero R, Hassan SS, Yeo L. Conde-Agudelo A, et al. Am J Obstet Gynecol. 2010 Aug;203(2):128.e1-12. doi: 10.1016/j.ajog.2010.02.064. Epub 2010 Jun 23. Am J Obstet Gynecol. 2010. PMID: 20576253 Free PMC article. Review. - Noninvasive Prenatal Testing for Trisomies 21, 18, and 13, Sex Chromosome Aneuploidies, and Microdeletions: A Health Technology Assessment.
Health Quality Ontario. Health Quality Ontario. Ont Health Technol Assess Ser. 2019 Feb 19;19(4):1-166. eCollection 2019. Ont Health Technol Assess Ser. 2019. PMID: 30847010 Free PMC article.
References
- Reid MC, Lachs MS, Feinstein AR. Use of methodological standards in diagnostic test research. Getting better but still not good. JAMA 1995;274:645-51. - PubMed
- Harper R, Reeves B. Compliance with methodological standards when evaluating ophthalmic diagnostic tests. Invest Ophthalmol Vis Sci 1999;40:1650-7. - PubMed
- Schulz KF, Chalmers I, Hayes RJ, et al. Empirical evidence of bias. Dimensions of methodological quality associated with estimates of treatment effects in controlled trials. JAMA. JAMA 1995;273:408-12. - PubMed
- Moher D, Pham B, Jones A, et al. Does quality of reports of randomised trials affect estimates of intervention efficacy reported in meta-analyses? Lancet 1998;352:609-13. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical