Optical aberrations in the mouse eye
Elena García de la Cera et al. Vision Res. 2006 Aug.
Free article
Abstract
Purpose: The mouse eye is a widely used model for retinal disease and has potential to become a model for myopia. Studies of retinal disease will benefit from imaging the fundus in vivo. Experimental models of myopia often rely on manipulation of the visual experience. In both cases, knowledge of the optical quality of the eye, and in particular, the retinal image quality degradation imposed by the ocular aberrations is essential. In this study, we measured the ocular aberrations in the wild type mouse.
Methods: Twelve eyes from six four-week old black C57BL/6 wild type mice were studied. Measurements were done on awake animals, one being also measured under anesthesia for comparative purposes. Ocular aberrations were measured using a custom-built Hartmann-Shack system (using 680-nm illumination). Wave aberrations are reported up to fourth order Zernike polynomials. Spherical equivalent and astigmatism were obtained from the 2nd order Zernike terms. Modulation Transfer Functions (MTF) were estimated for the best focus, and through-focus, to estimate depth-of-focus. All reported data were for 1.5-mm pupils.
Results: Hartmann-Shack refractions were consistently hyperopic (10.12+/-1.41 D, mean and standard deviation) and astigmatism was present in many of the eyes (3.64+/-3.70 D, on average). Spherical aberration was positive in all eyes (0.15+/-0.07 microm) and coma terms RMS were significantly high compared to other Zernike terms (0.10+/-0.03 microm). MTFs estimated from wave aberrations show a modulation of 0.4 at 2c/deg, for best focus (and 0.15 without cancelling the measured defocus). For that spatial frequency, depth-of-focus estimated from through-focus modulation data using the Rayleigh criterion was 6D. Aberrations in the eye of one anesthetized mouse were higher than in the same eye of the awake animal.
Conclusions: Hyperopic refractions in the mouse eye are consistent with previous retinoscopic data. The optics of the mouse eye is far from being diffraction-limited at 1.5-mm pupil, with significant amounts of spherical aberration and coma. However, estimates of MTFs from wave aberrations are higher than previously reported using a double-pass technique, resulting in smaller depth-of-field predictions. Despite the large degradation imposed by the aberrations these are lower than the amount of aberrations typically corrected by available correction techniques (i.e., adaptive optics). On the other hand, aberrations do not seem to be the limiting factor in the mouse spatial resolution. While the mouse optics are much more degraded than in other experimental models of myopia, its tolerance to large amounts of defocus does not seem to be determined entirely by the ocular aberrations.
Similar articles
- Custom optimization of intraocular lens asphericity.
Wang L, Koch DD. Wang L, et al. J Cataract Refract Surg. 2007 Oct;33(10):1713-20. doi: 10.1016/j.jcrs.2007.07.010. J Cataract Refract Surg. 2007. PMID: 17889765 - In vivo biometry in the mouse eye with low coherence interferometry.
Schmucker C, Schaeffel F. Schmucker C, et al. Vision Res. 2004;44(21):2445-56. doi: 10.1016/j.visres.2004.05.018. Vision Res. 2004. PMID: 15358080 - Longitudinal changes of optical aberrations in normal and form-deprived myopic chick eyes.
García de la Cera E, Rodríguez G, Marcos S. García de la Cera E, et al. Vision Res. 2006 Feb;46(4):579-89. doi: 10.1016/j.visres.2005.06.012. Epub 2005 Jul 26. Vision Res. 2006. PMID: 16051309 - Wave aberration of human eyes and new descriptors of image optical quality and visual performance.
Lombardo M, Lombardo G. Lombardo M, et al. J Cataract Refract Surg. 2010 Feb;36(2):313-31. doi: 10.1016/j.jcrs.2009.09.026. J Cataract Refract Surg. 2010. PMID: 20152616 Review. - Modeling human eye aberrations and their compensation for high-resolution retinal imaging.
Zhu L, Bartsch DU, Freeman WR, Sun PC, Fainman Y. Zhu L, et al. Optom Vis Sci. 1998 Nov;75(11):827-39. doi: 10.1097/00006324-199811000-00025. Optom Vis Sci. 1998. PMID: 9848838 Review.
Cited by
- A Novel Technique for Corneal Transepithelial Electrical Resistance Measurement in Mice.
Mohamed YH, Uematsu M, Kusano M, Inoue D, Tang D, Suzuki K, Kitaoka T. Mohamed YH, et al. Life (Basel). 2024 Aug 22;14(8):1046. doi: 10.3390/life14081046. Life (Basel). 2024. PMID: 39202787 Free PMC article. - Time-Serial Evaluation of the Development and Treatment of Myopia in Mice Eyes Using OCT and ZEMAX.
Ding X, Tan J, Meng J, Shao Y, Shen M, Dai C. Ding X, et al. Diagnostics (Basel). 2023 Jan 19;13(3):379. doi: 10.3390/diagnostics13030379. Diagnostics (Basel). 2023. PMID: 36766483 Free PMC article. - Anatomy and Histology of the Eye of the Nutria Myocastor coypus: Evidence of Adaptation to a Semi-aquatic Life.
Miyazaki T, Naritsuka Y, Yagami M, Kobayashi S, Kawamura K. Miyazaki T, et al. Zool Stud. 2022 May 10;61:e18. doi: 10.6620/ZS.2022.61-18. eCollection 2022. Zool Stud. 2022. PMID: 36330029 Free PMC article. - Recent advances in optical coherence tomography for anterior segment imaging in small animals and their clinical implications.
Beckmann L, Cai Z, Margolis M, Fang R, Djalilian A, Zhang HF. Beckmann L, et al. Ocul Surf. 2022 Oct;26:222-233. doi: 10.1016/j.jtos.2022.08.011. Epub 2022 Oct 3. Ocul Surf. 2022. PMID: 36195237 Free PMC article. Review. - Adaptive optics: principles and applications in ophthalmology.
Akyol E, Hagag AM, Sivaprasad S, Lotery AJ. Akyol E, et al. Eye (Lond). 2021 Jan;35(1):244-264. doi: 10.1038/s41433-020-01286-z. Epub 2020 Nov 30. Eye (Lond). 2021. PMID: 33257798 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous