Peak force and rate of force development during isometric and dynamic mid-thigh clean pulls performed at various intensities - PubMed (original) (raw)
Peak force and rate of force development during isometric and dynamic mid-thigh clean pulls performed at various intensities
Naoki Kawamori et al. J Strength Cond Res. 2006 Aug.
Abstract
Eight male collegiate weightlifters (age: 21.2 +/- 0.9 years; height: 177.6 +/- 2.3 cm; and body mass: 85.1 +/- 3.3 kg) participated in this study to compare isometric to dynamic force-time dependent variables. Subjects performed the isometric and dynamic mid-thigh clean pulls at 30-120% of their one repetition maximum (1RM) power clean (118.4 +/- 5.5 kg) on a 61 x 121.9-cm AMTI forceplate. Variables such as peak force (PF) and peak rate of force development (PRFD) were calculated and were compared between isometric and dynamic conditions. The relationships between force-time dependent variables and vertical jump performances also were examined. The data indicate that the isometric PF had no significant correlations with the dynamic PF against light loads. On the one hand, there was a general trend toward stronger relationships between the isometric and dynamic PF as the external load increased for dynamic muscle actions. On the other hand, the isometric and dynamic PRFD had no significant correlations regardless of the external load used for dynamic testing. In addition, the isometric PF and dynamic PRFD were shown to be strongly correlated with vertical jump performances, whereas the isometric PRFD and dynamic PF had no significant correlations with vertical jump performances. In conclusion, it appears that the isometric and dynamic measures of force-time curve characteristics represent relatively specific qualities, especially when dynamic testing involves small external loads. Additionally, the results suggest that athletes who possess greater isometric maximum strength and dynamic explosive strength tend to be able to jump higher.
Similar articles
- Force-time curve characteristics of dynamic and isometric muscle actions of elite women olympic weightlifters.
Haff GG, Carlock JM, Hartman MJ, Kilgore JL, Kawamori N, Jackson JR, Morris RT, Sands WA, Stone MH. Haff GG, et al. J Strength Cond Res. 2005 Nov;19(4):741-8. doi: 10.1519/R-15134.1. J Strength Cond Res. 2005. PMID: 16287343 - Relationship between countermovement jump performance and multijoint isometric and dynamic tests of strength.
Nuzzo JL, McBride JM, Cormie P, McCaulley GO. Nuzzo JL, et al. J Strength Cond Res. 2008 May;22(3):699-707. doi: 10.1519/JSC.0b013e31816d5eda. J Strength Cond Res. 2008. PMID: 18438251 - Relationship between force-time and velocity-time characteristics of dynamic and isometric muscle actions.
Khamoui AV, Brown LE, Nguyen D, Uribe BP, Coburn JW, Noffal GJ, Tran T. Khamoui AV, et al. J Strength Cond Res. 2011 Jan;25(1):198-204. doi: 10.1519/JSC.0b013e3181b94a7b. J Strength Cond Res. 2011. PMID: 19966585 - A review of the reliability of biomechanical variables produced during the isometric mid-thigh pull and isometric squat and the reporting of normative data.
Brady CJ, Harrison AJ, Comyns TM. Brady CJ, et al. Sports Biomech. 2020 Feb;19(1):1-25. doi: 10.1080/14763141.2018.1452968. Epub 2018 May 21. Sports Biomech. 2020. PMID: 29781788 Review. - The Relationship between Isometric Force-Time Characteristics and Dynamic Performance: A Systematic Review.
Lum D, Haff GG, Barbosa TM. Lum D, et al. Sports (Basel). 2020 May 15;8(5):63. doi: 10.3390/sports8050063. Sports (Basel). 2020. PMID: 32429176 Free PMC article. Review.
Cited by
- Muscle and tendon morphology of a world strongman and deadlift champion.
Balshaw TG, Massey GJ, Miller R, McDermott EJ, Maden-Wilkinson TM, Folland JP. Balshaw TG, et al. J Appl Physiol (1985). 2024 Oct 1;137(4):789-799. doi: 10.1152/japplphysiol.00342.2024. Epub 2024 Aug 15. J Appl Physiol (1985). 2024. PMID: 39143902 Free PMC article. - Characterization of Great Toe Extension Strength Using ToeScale-A Novel Portable Device.
Chandrashekhar R, Perez LF, Wang H. Chandrashekhar R, et al. Sensors (Basel). 2024 Jul 25;24(15):4841. doi: 10.3390/s24154841. Sensors (Basel). 2024. PMID: 39123887 Free PMC article. - Can isometric testing substitute for the one repetition maximum squat test?
Warneke K, Keiner M, Behm DG, Wirth K, Kaufmann M, Sproll M, Konrad A, Wallot S, Hillebrecht M. Warneke K, et al. Eur J Appl Physiol. 2024 Dec;124(12):3683-3692. doi: 10.1007/s00421-024-05554-8. Epub 2024 Aug 5. Eur J Appl Physiol. 2024. PMID: 39098977 Free PMC article. - Relationship between impulse and kinetic variables during jumping and landing in volleyball players.
Molla RY, Fatahi A, Khezri D, Ceylan HI, Nobari H. Molla RY, et al. BMC Musculoskelet Disord. 2023 Jul 29;24(1):619. doi: 10.1186/s12891-023-06757-4. BMC Musculoskelet Disord. 2023. PMID: 37516876 Free PMC article. - Validity and reliability of upper body push and pull tests to determine one-repetition maximum.
Sigvaldsen E, Loturco I, Larsen F, Bruusgaard J, Kalhovde JM, Haugen T. Sigvaldsen E, et al. PLoS One. 2023 Jul 13;18(7):e0288649. doi: 10.1371/journal.pone.0288649. eCollection 2023. PLoS One. 2023. PMID: 37440572 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources